ABAP Select data from SAP table HR99S_S_DAQ_WAFOR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP HR99S_S_DAQ_WAFOR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HR99S_S_DAQ_WAFOR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the HR99S_S_DAQ_WAFOR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_HR99S_S_DAQ_WAFOR TYPE STANDARD TABLE OF HR99S_S_DAQ_WAFOR, WA_HR99S_S_DAQ_WAFOR TYPE HR99S_S_DAQ_WAFOR, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <HR99S_S_DAQ_WAFOR> TYPE HR99S_S_DAQ_WAFOR. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_HR99S_S_DAQ_WAFOR. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM HR99S_S_DAQ_WAFOR INTO TABLE IT_HR99S_S_DAQ_WAFOR. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM HR99S_S_DAQ_WAFOR * INTO TABLE @DATA(IT_HR99S_S_DAQ_WAFOR2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_HR99S_S_DAQ_WAFOR INDEX 1 INTO DATA(WA_HR99S_S_DAQ_WAFOR2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_HR99S_S_DAQ_WAFOR ASSIGNING <HR99S_S_DAQ_WAFOR>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<HR99S_S_DAQ_WAFOR>-SECTN = 1.
<HR99S_S_DAQ_WAFOR>-SEATR = 1.
<HR99S_S_DAQ_WAFOR>-STYPE = 1.
<HR99S_S_DAQ_WAFOR>-TMSLT = 1.
<HR99S_S_DAQ_WAFOR>-CUMTM = 1.
ENDLOOP. LOOP AT IT_HR99S_S_DAQ_WAFOR INTO WA_HR99S_S_DAQ_WAFOR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_HR99S_S_DAQ_WAFOR-CUMEE, sy-vline,
WA_HR99S_S_DAQ_WAFOR-CONDT, sy-vline,
WA_HR99S_S_DAQ_WAFOR-FILE, sy-vline,
WA_HR99S_S_DAQ_WAFOR-STRCT, sy-vline,
WA_HR99S_S_DAQ_WAFOR-PRESE, sy-vline,
WA_HR99S_S_DAQ_WAFOR-HILEV, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HR99S_S_DAQ_WAFOR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HR99S_S_DAQ_WAFOR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HR99S_S_DAQ_WAFOR INTO WA_HR99S_S_DAQ_WAFOR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HR99S_S_DAQ_WAFOR_STR,
SECTN TYPE STRING,
SEATR TYPE STRING,
STYPE TYPE STRING,
TMSLT TYPE STRING,
CUMTM TYPE STRING,
CUMEE TYPE STRING,
CONDT TYPE STRING,
FILE TYPE STRING,
STRCT TYPE STRING,
PRESE TYPE STRING,
HILEV TYPE STRING,
IDVAL TYPE STRING,
IDLEN TYPE STRING,
IDOFF TYPE STRING,
TEXT TYPE STRING,
XMLTG TYPE STRING,
XMLT2 TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
INSEC TYPE STRING,
INTYP TYPE STRING,
INATR TYPE STRING,
GRPSE TYPE STRING,
FIELD TYPE STRING,
FICON TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
FTYPE TYPE STRING,
TMSLT TYPE STRING,
CUMTM TYPE STRING,
CUMEE TYPE STRING,
CUMSP TYPE STRING,
CONDT TYPE STRING,
KEYFO TYPE STRING,
KEYSE TYPE STRING,
XMLTG TYPE STRING,
OBLIG TYPE STRING,
ORDSE TYPE STRING,
XMSCT TYPE STRING,
INFLD TYPE STRING,
INATR TYPE STRING,
RDIFF TYPE STRING,
XMORD TYPE STRING,
CPDEC TYPE STRING,
QUALF TYPE STRING,
XMLT2 TYPE STRING,
FIDAQ TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
FNAME TYPE STRING,
SOUTY TYPE STRING,
SOUWT TYPE STRING,
SOUTA TYPE STRING,
SOUFI TYPE STRING,
SOUGR TYPE STRING,
DATTY TYPE STRING,
DATST TYPE STRING,
CONDI TYPE STRING,
TEXT TYPE STRING,
GENRC TYPE STRING,END OF T_EKKO_STR. DATA: WA_HR99S_S_DAQ_WAFOR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-SECTN sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-SEATR sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-STYPE sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-TMSLT sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-CUMTM sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-CUMEE sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-CONDT sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-FILE sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-STRCT sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-PRESE sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-HILEV sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-IDVAL sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-IDLEN sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-IDOFF sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-TEXT sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-XMLTG sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-XMLT2 sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-BEGDA sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-ENDDA sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-INSEC sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-INTYP sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-INATR sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-GRPSE sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-FIELD sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-FICON sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-ENDDA sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-BEGDA sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-FTYPE sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-TMSLT sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-CUMTM sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-CUMEE sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-CUMSP sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-CONDT sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-KEYFO sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-KEYSE sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-XMLTG sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-OBLIG sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-ORDSE sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-XMSCT sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-INFLD sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-INATR sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-RDIFF sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-XMORD sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-CPDEC sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-QUALF sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-XMLT2 sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-FIDAQ sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-ENDDA sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-BEGDA sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-FNAME sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-SOUTY sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-SOUWT sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-SOUTA sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-SOUFI sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-SOUGR sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-DATTY sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-DATST sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-CONDI sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-TEXT sy-vline
WA_HR99S_S_DAQ_WAFOR_STR-GENRC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.