ABAP Select data from SAP table HRNL_SBRAANLEVER_MESSAGE_RESPO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRNL_SBRAANLEVER_MESSAGE_RESPO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRNL_SBRAANLEVER_MESSAGE_RESPO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HRNL_SBRAANLEVER_MESSAGE_RESPO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HRNL_SBRAANLEVER_MESSAGE_RESPO TYPE STANDARD TABLE OF HRNL_SBRAANLEVER_MESSAGE_RESPO,
      WA_HRNL_SBRAANLEVER_MESSAGE_RESPO TYPE HRNL_SBRAANLEVER_MESSAGE_RESPO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HRNL_SBRAANLEVER_MESSAGE_RESPO> TYPE HRNL_SBRAANLEVER_MESSAGE_RESPO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HRNL_SBRAANLEVER_MESSAGE_RESPO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HRNL_SBRAANLEVER_MESSAGE_RESPO
  INTO TABLE IT_HRNL_SBRAANLEVER_MESSAGE_RESPO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HRNL_SBRAANLEVER_MESSAGE_RESPO
*  INTO TABLE @DATA(IT_HRNL_SBRAANLEVER_MESSAGE_RESPO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HRNL_SBRAANLEVER_MESSAGE_RESPO INDEX 1 INTO DATA(WA_HRNL_SBRAANLEVER_MESSAGE_RESPO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HRNL_SBRAANLEVER_MESSAGE_RESPO ASSIGNING <HRNL_SBRAANLEVER_MESSAGE_RESPO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRNL_SBRAANLEVER_MESSAGE_RESPO>-CONTROLLER = 1.
<HRNL_SBRAANLEVER_MESSAGE_RESPO>-KENMERK = 1.
<HRNL_SBRAANLEVER_MESSAGE_RESPO>-BERICHTSOORT = 1.
<HRNL_SBRAANLEVER_MESSAGE_RESPO>-AANLEVERKENMERK = 1.
<HRNL_SBRAANLEVER_MESSAGE_RESPO>-EERDER_AANLEVERKENMERK = 1.
ENDLOOP.

LOOP AT IT_HRNL_SBRAANLEVER_MESSAGE_RESPO INTO WA_HRNL_SBRAANLEVER_MESSAGE_RESPO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HRNL_SBRAANLEVER_MESSAGE_RESPO-TIJDSTEMPEL_AANGELEVERD, sy-vline,
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO-IDENTITEIT_BELANGHEBBENDE, sy-vline,
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO-CONTROLLER, sy-vline,
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO-NUMMER, sy-vline,
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO-TYPE, sy-vline,
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO-ROL_BELANGHEBBENDE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HRNL_SBRAANLEVER_MESSAGE_RESPO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRNL_SBRAANLEVER_MESSAGE_RESPO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRNL_SBRAANLEVER_MESSAGE_RESPO INTO WA_HRNL_SBRAANLEVER_MESSAGE_RESPO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR,
CONTROLLER TYPE STRING,
KENMERK TYPE STRING,
BERICHTSOORT TYPE STRING,
AANLEVERKENMERK TYPE STRING,
EERDER_AANLEVERKENMERK TYPE STRING,
TIJDSTEMPEL_AANGELEVERD TYPE STRING,
IDENTITEIT_BELANGHEBBENDE TYPE STRING,
CONTROLLER TYPE STRING,
NUMMER TYPE STRING,
TYPE TYPE STRING,
ROL_BELANGHEBBENDE TYPE STRING,
IDENTITEIT_ONTVANGER TYPE STRING,
CONTROLLER TYPE STRING,
NUMMER TYPE STRING,
TYPE TYPE STRING,
ROL_ONTVANGER TYPE STRING,
AUTORISATIE_ADRES TYPE STRING,
STATUSCODE TYPE STRING,
TIJDSTEMPEL_STATUS TYPE STRING,
STATUSOMSCHRIJVING TYPE STRING,
STATUS_FOUTCODE TYPE STRING,
CONTROLLER TYPE STRING,
FOUTCODE TYPE STRING,
FOUTBESCHRIJVING TYPE STRING,
STATUSDETAILS TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-CONTROLLER sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-KENMERK sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-BERICHTSOORT sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-AANLEVERKENMERK sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-EERDER_AANLEVERKENMERK sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-TIJDSTEMPEL_AANGELEVERD sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-IDENTITEIT_BELANGHEBBENDE sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-CONTROLLER sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-NUMMER sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-TYPE sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-ROL_BELANGHEBBENDE sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-IDENTITEIT_ONTVANGER sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-CONTROLLER sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-NUMMER sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-TYPE sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-ROL_ONTVANGER sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-AUTORISATIE_ADRES sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-STATUSCODE sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-TIJDSTEMPEL_STATUS sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-STATUSOMSCHRIJVING sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-STATUS_FOUTCODE sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-CONTROLLER sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-FOUTCODE sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-FOUTBESCHRIJVING sy-vline
WA_HRNL_SBRAANLEVER_MESSAGE_RESPO_STR-STATUSDETAILS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.