ABAP Select data from SAP table HRTNMFR_S_2483_CADREB_ALL_T into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRTNMFR_S_2483_CADREB_ALL_T table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRTNMFR_S_2483_CADREB_ALL_T. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HRTNMFR_S_2483_CADREB_ALL_T table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HRTNMFR_S_2483_CADREB_ALL_T TYPE STANDARD TABLE OF HRTNMFR_S_2483_CADREB_ALL_T,
      WA_HRTNMFR_S_2483_CADREB_ALL_T TYPE HRTNMFR_S_2483_CADREB_ALL_T,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HRTNMFR_S_2483_CADREB_ALL_T> TYPE HRTNMFR_S_2483_CADREB_ALL_T.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HRTNMFR_S_2483_CADREB_ALL_T.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HRTNMFR_S_2483_CADREB_ALL_T
  INTO TABLE IT_HRTNMFR_S_2483_CADREB_ALL_T.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HRTNMFR_S_2483_CADREB_ALL_T
*  INTO TABLE @DATA(IT_HRTNMFR_S_2483_CADREB_ALL_T2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HRTNMFR_S_2483_CADREB_ALL_T INDEX 1 INTO DATA(WA_HRTNMFR_S_2483_CADREB_ALL_T2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HRTNMFR_S_2483_CADREB_ALL_T ASSIGNING <HRTNMFR_S_2483_CADREB_ALL_T>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRTNMFR_S_2483_CADREB_ALL_T>-TRMEO = 1.
<HRTNMFR_S_2483_CADREB_ALL_T>-TRWOO = 1.
<HRTNMFR_S_2483_CADREB_ALL_T>-NBHRO = 1.
<HRTNMFR_S_2483_CADREB_ALL_T>-NDIFO = 1.
<HRTNMFR_S_2483_CADREB_ALL_T>-HDIFO = 1.
ENDLOOP.

LOOP AT IT_HRTNMFR_S_2483_CADREB_ALL_T INTO WA_HRTNMFR_S_2483_CADREB_ALL_T.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HRTNMFR_S_2483_CADREB_ALL_T-TRMEE, sy-vline,
WA_HRTNMFR_S_2483_CADREB_ALL_T-TRWOE, sy-vline,
WA_HRTNMFR_S_2483_CADREB_ALL_T-NBHRE, sy-vline,
WA_HRTNMFR_S_2483_CADREB_ALL_T-NDIFE, sy-vline,
WA_HRTNMFR_S_2483_CADREB_ALL_T-HDIFE, sy-vline,
WA_HRTNMFR_S_2483_CADREB_ALL_T-TRMET, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HRTNMFR_S_2483_CADREB_ALL_T you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRTNMFR_S_2483_CADREB_ALL_T TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRTNMFR_S_2483_CADREB_ALL_T INTO WA_HRTNMFR_S_2483_CADREB_ALL_T. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRTNMFR_S_2483_CADREB_ALL_T_STR,
TRMEO TYPE STRING,
TRWOO TYPE STRING,
NBHRO TYPE STRING,
NDIFO TYPE STRING,
HDIFO TYPE STRING,
TRMEE TYPE STRING,
TRWOE TYPE STRING,
NBHRE TYPE STRING,
NDIFE TYPE STRING,
HDIFE TYPE STRING,
TRMET TYPE STRING,
TRWOT TYPE STRING,
NBHRT TYPE STRING,
NDIFT TYPE STRING,
HDIFT TYPE STRING,
TRMEC TYPE STRING,
TRWOC TYPE STRING,
NBHRC TYPE STRING,
NDIFC TYPE STRING,
HDIFC TYPE STRING,
TRMEN TYPE STRING,
TRWOM TYPE STRING,
NBHRS TYPE STRING,
NBDIF TYPE STRING,
HRDIF TYPE STRING,
NBPRO TYPE STRING,
HRPRO TYPE STRING,
NALOC TYPE STRING,
HALOC TYPE STRING,
NBBDC TYPE STRING,
NBVAE TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRTNMFR_S_2483_CADREB_ALL_T_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-TRMEO sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-TRWOO sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-NBHRO sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-NDIFO sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-HDIFO sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-TRMEE sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-TRWOE sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-NBHRE sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-NDIFE sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-HDIFE sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-TRMET sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-TRWOT sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-NBHRT sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-NDIFT sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-HDIFT sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-TRMEC sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-TRWOC sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-NBHRC sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-NDIFC sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-HDIFC sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-TRMEN sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-TRWOM sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-NBHRS sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-NBDIF sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-HRDIF sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-NBPRO sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-HRPRO sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-NALOC sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-HALOC sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-NBBDC sy-vline
WA_HRTNMFR_S_2483_CADREB_ALL_T_STR-NBVAE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.