ABAP Select data from SAP table HRTNMFR_T_2483_CADREB_ALL_P into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRTNMFR_T_2483_CADREB_ALL_P table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRTNMFR_T_2483_CADREB_ALL_P. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HRTNMFR_T_2483_CADREB_ALL_P table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HRTNMFR_T_2483_CADREB_ALL_P TYPE STANDARD TABLE OF HRTNMFR_T_2483_CADREB_ALL_P,
      WA_HRTNMFR_T_2483_CADREB_ALL_P TYPE HRTNMFR_T_2483_CADREB_ALL_P,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HRTNMFR_T_2483_CADREB_ALL_P> TYPE HRTNMFR_T_2483_CADREB_ALL_P.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HRTNMFR_T_2483_CADREB_ALL_P.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HRTNMFR_T_2483_CADREB_ALL_P
  INTO TABLE IT_HRTNMFR_T_2483_CADREB_ALL_P.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HRTNMFR_T_2483_CADREB_ALL_P
*  INTO TABLE @DATA(IT_HRTNMFR_T_2483_CADREB_ALL_P2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HRTNMFR_T_2483_CADREB_ALL_P INDEX 1 INTO DATA(WA_HRTNMFR_T_2483_CADREB_ALL_P2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HRTNMFR_T_2483_CADREB_ALL_P ASSIGNING <HRTNMFR_T_2483_CADREB_ALL_P>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRTNMFR_T_2483_CADREB_ALL_P>-SECTN = 1.
<HRTNMFR_T_2483_CADREB_ALL_P>-NBMEO = 1.
<HRTNMFR_T_2483_CADREB_ALL_P>-NBWOO = 1.
<HRTNMFR_T_2483_CADREB_ALL_P>-DIFLO = 1.
<HRTNMFR_T_2483_CADREB_ALL_P>-NBMEE = 1.
ENDLOOP.

LOOP AT IT_HRTNMFR_T_2483_CADREB_ALL_P INTO WA_HRTNMFR_T_2483_CADREB_ALL_P.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HRTNMFR_T_2483_CADREB_ALL_P-NBWOE, sy-vline,
WA_HRTNMFR_T_2483_CADREB_ALL_P-DIFLE, sy-vline,
WA_HRTNMFR_T_2483_CADREB_ALL_P-NBMET, sy-vline,
WA_HRTNMFR_T_2483_CADREB_ALL_P-NBWOT, sy-vline,
WA_HRTNMFR_T_2483_CADREB_ALL_P-DIFLT, sy-vline,
WA_HRTNMFR_T_2483_CADREB_ALL_P-NBMEC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HRTNMFR_T_2483_CADREB_ALL_P you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRTNMFR_T_2483_CADREB_ALL_P TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRTNMFR_T_2483_CADREB_ALL_P INTO WA_HRTNMFR_T_2483_CADREB_ALL_P. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRTNMFR_T_2483_CADREB_ALL_P_STR,
SECTN TYPE STRING,
NBMEO TYPE STRING,
NBWOO TYPE STRING,
DIFLO TYPE STRING,
NBMEE TYPE STRING,
NBWOE TYPE STRING,
DIFLE TYPE STRING,
NBMET TYPE STRING,
NBWOT TYPE STRING,
DIFLT TYPE STRING,
NBMEC TYPE STRING,
NBWOC TYPE STRING,
DIFLC TYPE STRING,
TOTME TYPE STRING,
TOTWO TYPE STRING,
DIFLF TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRTNMFR_T_2483_CADREB_ALL_P_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-SECTN sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-NBMEO sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-NBWOO sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-DIFLO sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-NBMEE sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-NBWOE sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-DIFLE sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-NBMET sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-NBWOT sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-DIFLT sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-NBMEC sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-NBWOC sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-DIFLC sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-TOTME sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-TOTWO sy-vline
WA_HRTNMFR_T_2483_CADREB_ALL_P_STR-DIFLF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.