ABAP Select data from SAP table HRV_SHOWEVENTDATES into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRV_SHOWEVENTDATES table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRV_SHOWEVENTDATES. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the HRV_SHOWEVENTDATES table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_HRV_SHOWEVENTDATES TYPE STANDARD TABLE OF HRV_SHOWEVENTDATES, WA_HRV_SHOWEVENTDATES TYPE HRV_SHOWEVENTDATES, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <HRV_SHOWEVENTDATES> TYPE HRV_SHOWEVENTDATES. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_HRV_SHOWEVENTDATES. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM HRV_SHOWEVENTDATES INTO TABLE IT_HRV_SHOWEVENTDATES. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM HRV_SHOWEVENTDATES * INTO TABLE @DATA(IT_HRV_SHOWEVENTDATES2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_HRV_SHOWEVENTDATES INDEX 1 INTO DATA(WA_HRV_SHOWEVENTDATES2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_HRV_SHOWEVENTDATES ASSIGNING <HRV_SHOWEVENTDATES>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRV_SHOWEVENTDATES>-EVBEG = 1.
<HRV_SHOWEVENTDATES>-EVEND = 1.
<HRV_SHOWEVENTDATES>-LOCTYP = 1.
<HRV_SHOWEVENTDATES>-LOCID = 1.
<HRV_SHOWEVENTDATES>-EVLOC = 1.
ENDLOOP. LOOP AT IT_HRV_SHOWEVENTDATES INTO WA_HRV_SHOWEVENTDATES. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_HRV_SHOWEVENTDATES-EVLNG, sy-vline,
WA_HRV_SHOWEVENTDATES-EOTYP, sy-vline,
WA_HRV_SHOWEVENTDATES-EVEID, sy-vline,
WA_HRV_SHOWEVENTDATES-EVESH, sy-vline,
ENDLOOP. *Add any further fields from structure WA_HRV_SHOWEVENTDATES you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRV_SHOWEVENTDATES TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRV_SHOWEVENTDATES INTO WA_HRV_SHOWEVENTDATES. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ISOLA, internal->external for field EVLNG CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_HRV_SHOWEVENTDATES-EVLNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HRV_SHOWEVENTDATES-EVLNG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRV_SHOWEVENTDATES_STR,
EVBEG TYPE STRING,
EVEND TYPE STRING,
LOCTYP TYPE STRING,
LOCID TYPE STRING,
EVLOC TYPE STRING,
EVLNG TYPE STRING,
EOTYP TYPE STRING,
EVEID TYPE STRING,
EVESH TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRV_SHOWEVENTDATES_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRV_SHOWEVENTDATES_STR-EVBEG sy-vline
WA_HRV_SHOWEVENTDATES_STR-EVEND sy-vline
WA_HRV_SHOWEVENTDATES_STR-LOCTYP sy-vline
WA_HRV_SHOWEVENTDATES_STR-LOCID sy-vline
WA_HRV_SHOWEVENTDATES_STR-EVLOC sy-vline
WA_HRV_SHOWEVENTDATES_STR-EVLNG sy-vline
WA_HRV_SHOWEVENTDATES_STR-EOTYP sy-vline
WA_HRV_SHOWEVENTDATES_STR-EVEID sy-vline
WA_HRV_SHOWEVENTDATES_STR-EVESH sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.