ABAP Select data from SAP table HRXSS_REP_RFWTEST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HRXSS_REP_RFWTEST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HRXSS_REP_RFWTEST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HRXSS_REP_RFWTEST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HRXSS_REP_RFWTEST TYPE STANDARD TABLE OF HRXSS_REP_RFWTEST,
      WA_HRXSS_REP_RFWTEST TYPE HRXSS_REP_RFWTEST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HRXSS_REP_RFWTEST> TYPE HRXSS_REP_RFWTEST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HRXSS_REP_RFWTEST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HRXSS_REP_RFWTEST
  INTO TABLE IT_HRXSS_REP_RFWTEST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HRXSS_REP_RFWTEST
*  INTO TABLE @DATA(IT_HRXSS_REP_RFWTEST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HRXSS_REP_RFWTEST INDEX 1 INTO DATA(WA_HRXSS_REP_RFWTEST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HRXSS_REP_RFWTEST ASSIGNING <HRXSS_REP_RFWTEST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HRXSS_REP_RFWTEST>-APPLTEST = 1.
<HRXSS_REP_RFWTEST>-VCDATA = 1.
<HRXSS_REP_RFWTEST>-TABLE_NAME = 1.
<HRXSS_REP_RFWTEST>-ACTIONID_START = 1.
<HRXSS_REP_RFWTEST>-MAXROWS = 1.
ENDLOOP.

LOOP AT IT_HRXSS_REP_RFWTEST INTO WA_HRXSS_REP_RFWTEST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HRXSS_REP_RFWTEST-SELROWS, sy-vline,
WA_HRXSS_REP_RFWTEST-VCTABLE, sy-vline,
WA_HRXSS_REP_RFWTEST-TABLE0, sy-vline,
WA_HRXSS_REP_RFWTEST-FIELDCAT_TABLE0, sy-vline,
WA_HRXSS_REP_RFWTEST-CONTENT_TABLE0, sy-vline,
WA_HRXSS_REP_RFWTEST-RFWNAV0, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HRXSS_REP_RFWTEST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HRXSS_REP_RFWTEST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HRXSS_REP_RFWTEST INTO WA_HRXSS_REP_RFWTEST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HRXSS_REP_RFWTEST_STR,
APPLTEST TYPE STRING,
VCDATA TYPE STRING,
TABLE_NAME TYPE STRING,
ACTIONID_START TYPE STRING,
MAXROWS TYPE STRING,
SELROWS TYPE STRING,
VCTABLE TYPE STRING,
TABLE0 TYPE STRING,
FIELDCAT_TABLE0 TYPE STRING,
CONTENT_TABLE0 TYPE STRING,
RFWNAV0 TYPE STRING,
BPREV_ACTIONID TYPE STRING,
BNEXT_ACTIONID TYPE STRING,
BEXIT_ACTIONID TYPE STRING,
BOTHERS_ACTIONID TYPE STRING,
BPREV_ENABLED TYPE STRING,
BNEXT_ENABLED TYPE STRING,
BEXIT_ENABLED TYPE STRING,
BOTHERS_ENABLED TYPE STRING,
BPREV_VISIBLE TYPE STRING,
BNEXT_VISIBLE TYPE STRING,
BEXIT_VISIBLE TYPE STRING,
BOTHERS_VISIBLE TYPE STRING,END OF T_EKKO_STR. DATA: WA_HRXSS_REP_RFWTEST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HRXSS_REP_RFWTEST_STR-APPLTEST sy-vline
WA_HRXSS_REP_RFWTEST_STR-VCDATA sy-vline
WA_HRXSS_REP_RFWTEST_STR-TABLE_NAME sy-vline
WA_HRXSS_REP_RFWTEST_STR-ACTIONID_START sy-vline
WA_HRXSS_REP_RFWTEST_STR-MAXROWS sy-vline
WA_HRXSS_REP_RFWTEST_STR-SELROWS sy-vline
WA_HRXSS_REP_RFWTEST_STR-VCTABLE sy-vline
WA_HRXSS_REP_RFWTEST_STR-TABLE0 sy-vline
WA_HRXSS_REP_RFWTEST_STR-FIELDCAT_TABLE0 sy-vline
WA_HRXSS_REP_RFWTEST_STR-CONTENT_TABLE0 sy-vline
WA_HRXSS_REP_RFWTEST_STR-RFWNAV0 sy-vline
WA_HRXSS_REP_RFWTEST_STR-BPREV_ACTIONID sy-vline
WA_HRXSS_REP_RFWTEST_STR-BNEXT_ACTIONID sy-vline
WA_HRXSS_REP_RFWTEST_STR-BEXIT_ACTIONID sy-vline
WA_HRXSS_REP_RFWTEST_STR-BOTHERS_ACTIONID sy-vline
WA_HRXSS_REP_RFWTEST_STR-BPREV_ENABLED sy-vline
WA_HRXSS_REP_RFWTEST_STR-BNEXT_ENABLED sy-vline
WA_HRXSS_REP_RFWTEST_STR-BEXIT_ENABLED sy-vline
WA_HRXSS_REP_RFWTEST_STR-BOTHERS_ENABLED sy-vline
WA_HRXSS_REP_RFWTEST_STR-BPREV_VISIBLE sy-vline
WA_HRXSS_REP_RFWTEST_STR-BNEXT_VISIBLE sy-vline
WA_HRXSS_REP_RFWTEST_STR-BEXIT_VISIBLE sy-vline
WA_HRXSS_REP_RFWTEST_STR-BOTHERS_VISIBLE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.