ABAP Select data from SAP table IAOM_ASSIGNM_HST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IAOM_ASSIGNM_HST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IAOM_ASSIGNM_HST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IAOM_ASSIGNM_HST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IAOM_ASSIGNM_HST TYPE STANDARD TABLE OF IAOM_ASSIGNM_HST,
      WA_IAOM_ASSIGNM_HST TYPE IAOM_ASSIGNM_HST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IAOM_ASSIGNM_HST> TYPE IAOM_ASSIGNM_HST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IAOM_ASSIGNM_HST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IAOM_ASSIGNM_HST
  INTO TABLE IT_IAOM_ASSIGNM_HST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IAOM_ASSIGNM_HST
*  INTO TABLE @DATA(IT_IAOM_ASSIGNM_HST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IAOM_ASSIGNM_HST INDEX 1 INTO DATA(WA_IAOM_ASSIGNM_HST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IAOM_ASSIGNM_HST ASSIGNING <IAOM_ASSIGNM_HST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IAOM_ASSIGNM_HST>-MANDT = 1.
<IAOM_ASSIGNM_HST>-BUS_SCENARIO_ID = 1.
<IAOM_ASSIGNM_HST>-EXT_OBJECT_ID = 1.
<IAOM_ASSIGNM_HST>-VALID_TO_DATE = 1.
<IAOM_ASSIGNM_HST>-VALID_TO_TIME = 1.
ENDLOOP.

LOOP AT IT_IAOM_ASSIGNM_HST INTO WA_IAOM_ASSIGNM_HST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IAOM_ASSIGNM_HST-OBJECT_NO, sy-vline,
WA_IAOM_ASSIGNM_HST-PROFIT_CENTRE, sy-vline,
WA_IAOM_ASSIGNM_HST-CONTROLLING_TYPE, sy-vline,
WA_IAOM_ASSIGNM_HST-OBJECT_NO_SET, sy-vline,
WA_IAOM_ASSIGNM_HST-CONTROL_TYPE_SET, sy-vline,
WA_IAOM_ASSIGNM_HST-OBJECT_NO_REC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IAOM_ASSIGNM_HST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IAOM_ASSIGNM_HST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IAOM_ASSIGNM_HST INTO WA_IAOM_ASSIGNM_HST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PROFIT_CENTRE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IAOM_ASSIGNM_HST-PROFIT_CENTRE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IAOM_ASSIGNM_HST-PROFIT_CENTRE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IAOM_ASSIGNM_HST_STR,
MANDT TYPE STRING,
BUS_SCENARIO_ID TYPE STRING,
EXT_OBJECT_ID TYPE STRING,
VALID_TO_DATE TYPE STRING,
VALID_TO_TIME TYPE STRING,
OBJECT_NO TYPE STRING,
PROFIT_CENTRE TYPE STRING,
CONTROLLING_TYPE TYPE STRING,
OBJECT_NO_SET TYPE STRING,
CONTROL_TYPE_SET TYPE STRING,
OBJECT_NO_REC TYPE STRING,END OF T_EKKO_STR. DATA: WA_IAOM_ASSIGNM_HST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IAOM_ASSIGNM_HST_STR-MANDT sy-vline
WA_IAOM_ASSIGNM_HST_STR-BUS_SCENARIO_ID sy-vline
WA_IAOM_ASSIGNM_HST_STR-EXT_OBJECT_ID sy-vline
WA_IAOM_ASSIGNM_HST_STR-VALID_TO_DATE sy-vline
WA_IAOM_ASSIGNM_HST_STR-VALID_TO_TIME sy-vline
WA_IAOM_ASSIGNM_HST_STR-OBJECT_NO sy-vline
WA_IAOM_ASSIGNM_HST_STR-PROFIT_CENTRE sy-vline
WA_IAOM_ASSIGNM_HST_STR-CONTROLLING_TYPE sy-vline
WA_IAOM_ASSIGNM_HST_STR-OBJECT_NO_SET sy-vline
WA_IAOM_ASSIGNM_HST_STR-CONTROL_TYPE_SET sy-vline
WA_IAOM_ASSIGNM_HST_STR-OBJECT_NO_REC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.