ABAP Select data from SAP table ICA_S_ASSIGN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ICA_S_ASSIGN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ICA_S_ASSIGN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ICA_S_ASSIGN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ICA_S_ASSIGN TYPE STANDARD TABLE OF ICA_S_ASSIGN,
      WA_ICA_S_ASSIGN TYPE ICA_S_ASSIGN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ICA_S_ASSIGN> TYPE ICA_S_ASSIGN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ICA_S_ASSIGN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ICA_S_ASSIGN
  INTO TABLE IT_ICA_S_ASSIGN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ICA_S_ASSIGN
*  INTO TABLE @DATA(IT_ICA_S_ASSIGN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ICA_S_ASSIGN INDEX 1 INTO DATA(WA_ICA_S_ASSIGN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ICA_S_ASSIGN ASSIGNING <ICA_S_ASSIGN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ICA_S_ASSIGN>-GRREF = 1.
<ICA_S_ASSIGN>-METHOD_ID = 1.
<ICA_S_ASSIGN>-RULE_ID = 1.
<ICA_S_ASSIGN>-MATCH_TYPE = 1.
<ICA_S_ASSIGN>-RCODE = 1.
ENDLOOP.

LOOP AT IT_ICA_S_ASSIGN INTO WA_ICA_S_ASSIGN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ICA_S_ASSIGN-TEMPORAL, sy-vline,
WA_ICA_S_ASSIGN-TRIGGER_PARTNER_SIDE, sy-vline,
WA_ICA_S_ASSIGN-WF_SCENARIO_ID, sy-vline,
WA_ICA_S_ASSIGN-WF_STATUS, sy-vline,
WA_ICA_S_ASSIGN-UNASSIGNED, sy-vline,
WA_ICA_S_ASSIGN-COMMENT_CNT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ICA_S_ASSIGN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ICA_S_ASSIGN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ICA_S_ASSIGN INTO WA_ICA_S_ASSIGN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_ICA_S_ASSIGN-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICA_S_ASSIGN-RYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI7, internal->external for field FISCYEARPER CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_ICA_S_ASSIGN-FISCYEARPER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICA_S_ASSIGN-FISCYEARPER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICA_S_ASSIGN-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICA_S_ASSIGN-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICA_S_ASSIGN-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICA_S_ASSIGN-RVERS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ICA_S_ASSIGN_STR,
GRREF TYPE STRING,
METHOD_ID TYPE STRING,
RULE_ID TYPE STRING,
MATCH_TYPE TYPE STRING,
RCODE TYPE STRING,
TEMPORAL TYPE STRING,
TRIGGER_PARTNER_SIDE TYPE STRING,
WF_SCENARIO_ID TYPE STRING,
WF_STATUS TYPE STRING,
UNASSIGNED TYPE STRING,
COMMENT_CNT TYPE STRING,
PSTAT TYPE STRING,
FILTER TYPE STRING,
FILTER_STR TYPE STRING,
LUNIT_STR TYPE STRING,
PERIV TYPE STRING,
RYEAR TYPE STRING,
POPER TYPE STRING,
FISCYEARPER TYPE STRING,
RLDNR TYPE STRING,
RVERS TYPE STRING,
RITCLG TYPE STRING,
CREATEDBY TYPE STRING,
CREATEDAT TYPE STRING,
CHANGEDBY TYPE STRING,
CHANGEDAT TYPE STRING,
SELECTED TYPE STRING,
IS_DUE TYPE STRING,
IS_DUE_TODAY TYPE STRING,
GROUP_PROB TYPE STRING,END OF T_EKKO_STR. DATA: WA_ICA_S_ASSIGN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ICA_S_ASSIGN_STR-GRREF sy-vline
WA_ICA_S_ASSIGN_STR-METHOD_ID sy-vline
WA_ICA_S_ASSIGN_STR-RULE_ID sy-vline
WA_ICA_S_ASSIGN_STR-MATCH_TYPE sy-vline
WA_ICA_S_ASSIGN_STR-RCODE sy-vline
WA_ICA_S_ASSIGN_STR-TEMPORAL sy-vline
WA_ICA_S_ASSIGN_STR-TRIGGER_PARTNER_SIDE sy-vline
WA_ICA_S_ASSIGN_STR-WF_SCENARIO_ID sy-vline
WA_ICA_S_ASSIGN_STR-WF_STATUS sy-vline
WA_ICA_S_ASSIGN_STR-UNASSIGNED sy-vline
WA_ICA_S_ASSIGN_STR-COMMENT_CNT sy-vline
WA_ICA_S_ASSIGN_STR-PSTAT sy-vline
WA_ICA_S_ASSIGN_STR-FILTER sy-vline
WA_ICA_S_ASSIGN_STR-FILTER_STR sy-vline
WA_ICA_S_ASSIGN_STR-LUNIT_STR sy-vline
WA_ICA_S_ASSIGN_STR-PERIV sy-vline
WA_ICA_S_ASSIGN_STR-RYEAR sy-vline
WA_ICA_S_ASSIGN_STR-POPER sy-vline
WA_ICA_S_ASSIGN_STR-FISCYEARPER sy-vline
WA_ICA_S_ASSIGN_STR-RLDNR sy-vline
WA_ICA_S_ASSIGN_STR-RVERS sy-vline
WA_ICA_S_ASSIGN_STR-RITCLG sy-vline
WA_ICA_S_ASSIGN_STR-CREATEDBY sy-vline
WA_ICA_S_ASSIGN_STR-CREATEDAT sy-vline
WA_ICA_S_ASSIGN_STR-CHANGEDBY sy-vline
WA_ICA_S_ASSIGN_STR-CHANGEDAT sy-vline
WA_ICA_S_ASSIGN_STR-SELECTED sy-vline
WA_ICA_S_ASSIGN_STR-IS_DUE sy-vline
WA_ICA_S_ASSIGN_STR-IS_DUE_TODAY sy-vline
WA_ICA_S_ASSIGN_STR-GROUP_PROB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.