ABAP Select data from SAP table ICM_CONNINF into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ICM_CONNINF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ICM_CONNINF. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ICM_CONNINF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ICM_CONNINF TYPE STANDARD TABLE OF ICM_CONNINF, WA_ICM_CONNINF TYPE ICM_CONNINF, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ICM_CONNINF> TYPE ICM_CONNINF. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ICM_CONNINF. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ICM_CONNINF INTO TABLE IT_ICM_CONNINF. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ICM_CONNINF * INTO TABLE @DATA(IT_ICM_CONNINF2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ICM_CONNINF INDEX 1 INTO DATA(WA_ICM_CONNINF2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ICM_CONNINF ASSIGNING <ICM_CONNINF>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ICM_CONNINF>-CONN = 1.
<ICM_CONNINF>-GUID = 1.
<ICM_CONNINF>-ROLE = 1.
<ICM_CONNINF>-STATEFUL = 1.
<ICM_CONNINF>-NIHDL = 1.
ENDLOOP. LOOP AT IT_ICM_CONNINF INTO WA_ICM_CONNINF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ICM_CONNINF-OBJ_ID, sy-vline,
WA_ICM_CONNINF-OBJ_FD, sy-vline,
WA_ICM_CONNINF-TRACE_LVL, sy-vline,
WA_ICM_CONNINF-WP_TIMEOUT, sy-vline,
WA_ICM_CONNINF-STATUS, sy-vline,
WA_ICM_CONNINF-NEXT_STAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ICM_CONNINF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ICM_CONNINF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ICM_CONNINF INTO WA_ICM_CONNINF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ICM_CONNINF_STR,
CONN TYPE STRING,
GUID TYPE STRING,
ROLE TYPE STRING,
STATEFUL TYPE STRING,
NIHDL TYPE STRING,
OBJ_ID TYPE STRING,
OBJ_FD TYPE STRING,
TRACE_LVL TYPE STRING,
WP_TIMEOUT TYPE STRING,
STATUS TYPE STRING,
NEXT_STAT TYPE STRING,
HOSTNAME TYPE STRING,
SERVNAME TYPE STRING,
CON_TYPE TYPE STRING,
CON_TID TYPE STRING,
CON_MODE TYPE STRING,
CON_UID TYPE STRING,
CON_STATUS TYPE STRING,
CTXJ_ID TYPE STRING,
CTXJ_STATE TYPE STRING,
CTXJ_OPENREQ TYPE STRING,
ERR_USED TYPE STRING,
ERR_CODE TYPE STRING,
CONN_DATE TYPE STRING,
CONN_TIME TYPE STRING,
PROTOCOL TYPE STRING,
DUMMY1 TYPE STRING,
DUMMY2 TYPE STRING,
DUMMY3 TYPE STRING,
MONITOR_INFO TYPE STRING,END OF T_EKKO_STR. DATA: WA_ICM_CONNINF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ICM_CONNINF_STR-CONN sy-vline
WA_ICM_CONNINF_STR-GUID sy-vline
WA_ICM_CONNINF_STR-ROLE sy-vline
WA_ICM_CONNINF_STR-STATEFUL sy-vline
WA_ICM_CONNINF_STR-NIHDL sy-vline
WA_ICM_CONNINF_STR-OBJ_ID sy-vline
WA_ICM_CONNINF_STR-OBJ_FD sy-vline
WA_ICM_CONNINF_STR-TRACE_LVL sy-vline
WA_ICM_CONNINF_STR-WP_TIMEOUT sy-vline
WA_ICM_CONNINF_STR-STATUS sy-vline
WA_ICM_CONNINF_STR-NEXT_STAT sy-vline
WA_ICM_CONNINF_STR-HOSTNAME sy-vline
WA_ICM_CONNINF_STR-SERVNAME sy-vline
WA_ICM_CONNINF_STR-CON_TYPE sy-vline
WA_ICM_CONNINF_STR-CON_TID sy-vline
WA_ICM_CONNINF_STR-CON_MODE sy-vline
WA_ICM_CONNINF_STR-CON_UID sy-vline
WA_ICM_CONNINF_STR-CON_STATUS sy-vline
WA_ICM_CONNINF_STR-CTXJ_ID sy-vline
WA_ICM_CONNINF_STR-CTXJ_STATE sy-vline
WA_ICM_CONNINF_STR-CTXJ_OPENREQ sy-vline
WA_ICM_CONNINF_STR-ERR_USED sy-vline
WA_ICM_CONNINF_STR-ERR_CODE sy-vline
WA_ICM_CONNINF_STR-CONN_DATE sy-vline
WA_ICM_CONNINF_STR-CONN_TIME sy-vline
WA_ICM_CONNINF_STR-PROTOCOL sy-vline
WA_ICM_CONNINF_STR-DUMMY1 sy-vline
WA_ICM_CONNINF_STR-DUMMY2 sy-vline
WA_ICM_CONNINF_STR-DUMMY3 sy-vline
WA_ICM_CONNINF_STR-MONITOR_INFO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.