ABAP Select data from SAP table ICRSCTLGEOPANTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ICRSCTLGEOPANTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ICRSCTLGEOPANTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ICRSCTLGEOPANTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ICRSCTLGEOPANTP TYPE STANDARD TABLE OF ICRSCTLGEOPANTP,
      WA_ICRSCTLGEOPANTP TYPE ICRSCTLGEOPANTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ICRSCTLGEOPANTP> TYPE ICRSCTLGEOPANTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ICRSCTLGEOPANTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ICRSCTLGEOPANTP
  INTO TABLE IT_ICRSCTLGEOPANTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ICRSCTLGEOPANTP
*  INTO TABLE @DATA(IT_ICRSCTLGEOPANTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ICRSCTLGEOPANTP INDEX 1 INTO DATA(WA_ICRSCTLGEOPANTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ICRSCTLGEOPANTP ASSIGNING <ICRSCTLGEOPANTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ICRSCTLGEOPANTP>-MANDT = 1.
<ICRSCTLGEOPANTP>-CRSCTLGMAPPGEXTPARAMETERUUID = 1.
<ICRSCTLGEOPANTP>-CREATEDBYUSER = 1.
<ICRSCTLGEOPANTP>-CREATIONDATETIME = 1.
<ICRSCTLGEOPANTP>-LASTCHANGEDBYUSER = 1.
ENDLOOP.

LOOP AT IT_ICRSCTLGEOPANTP INTO WA_ICRSCTLGEOPANTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ICRSCTLGEOPANTP-LASTCHANGEDATETIME, sy-vline,
WA_ICRSCTLGEOPANTP-CRSCTLGMAPPGEXTOBJASSGMTUUID, sy-vline,
WA_ICRSCTLGEOPANTP-SUBSCRPNPRODSPECUUID, sy-vline,
WA_ICRSCTLGEOPANTP-CRSCTLGMAPPGEXTPARAMETERID, sy-vline,
WA_ICRSCTLGEOPANTP-CRSCTLGMAPPGEXTPARAMETERDESC, sy-vline,
WA_ICRSCTLGEOPANTP-CRSCTLGMAPPGEXTOBJECTPARAMTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ICRSCTLGEOPANTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ICRSCTLGEOPANTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ICRSCTLGEOPANTP INTO WA_ICRSCTLGEOPANTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ICRSCTLGEOPANTP_STR,
MANDT TYPE STRING,
CRSCTLGMAPPGEXTPARAMETERUUID TYPE STRING,
CREATEDBYUSER TYPE STRING,
CREATIONDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
LASTCHANGEDATETIME TYPE STRING,
CRSCTLGMAPPGEXTOBJASSGMTUUID TYPE STRING,
SUBSCRPNPRODSPECUUID TYPE STRING,
CRSCTLGMAPPGEXTPARAMETERID TYPE STRING,
CRSCTLGMAPPGEXTPARAMETERDESC TYPE STRING,
CRSCTLGMAPPGEXTOBJECTPARAMTYPE TYPE STRING,
CRSCTLGMAPPGEXTPARAMUSEVALUE TYPE STRING,
CRSCTLGMAPPGEXTPARAMNMRCVALUE TYPE STRING,
CRSCTLGMAPPGEXTPARAMNMRCDFLT TYPE STRING,
CRSCTLGMAPPGEXTPARAMSTRINGVAL TYPE STRING,
CRSCTLGMAPPGEXTPARAMSTRINGDFLT TYPE STRING,
CRSCTLGMAPPGEXTPARAMDATEVALUE TYPE STRING,
CRSCTLGMAPPGEXTPARAMDTEDFLTVAL TYPE STRING,
BRFFUNCTIONUUID TYPE STRING,
CRSCTLGMAPPGEXTPARAMISMAND TYPE STRING,
CHARACTERISTIC TYPE STRING,END OF T_EKKO_STR. DATA: WA_ICRSCTLGEOPANTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ICRSCTLGEOPANTP_STR-MANDT sy-vline
WA_ICRSCTLGEOPANTP_STR-CRSCTLGMAPPGEXTPARAMETERUUID sy-vline
WA_ICRSCTLGEOPANTP_STR-CREATEDBYUSER sy-vline
WA_ICRSCTLGEOPANTP_STR-CREATIONDATETIME sy-vline
WA_ICRSCTLGEOPANTP_STR-LASTCHANGEDBYUSER sy-vline
WA_ICRSCTLGEOPANTP_STR-LASTCHANGEDATETIME sy-vline
WA_ICRSCTLGEOPANTP_STR-CRSCTLGMAPPGEXTOBJASSGMTUUID sy-vline
WA_ICRSCTLGEOPANTP_STR-SUBSCRPNPRODSPECUUID sy-vline
WA_ICRSCTLGEOPANTP_STR-CRSCTLGMAPPGEXTPARAMETERID sy-vline
WA_ICRSCTLGEOPANTP_STR-CRSCTLGMAPPGEXTPARAMETERDESC sy-vline
WA_ICRSCTLGEOPANTP_STR-CRSCTLGMAPPGEXTOBJECTPARAMTYPE sy-vline
WA_ICRSCTLGEOPANTP_STR-CRSCTLGMAPPGEXTPARAMUSEVALUE sy-vline
WA_ICRSCTLGEOPANTP_STR-CRSCTLGMAPPGEXTPARAMNMRCVALUE sy-vline
WA_ICRSCTLGEOPANTP_STR-CRSCTLGMAPPGEXTPARAMNMRCDFLT sy-vline
WA_ICRSCTLGEOPANTP_STR-CRSCTLGMAPPGEXTPARAMSTRINGVAL sy-vline
WA_ICRSCTLGEOPANTP_STR-CRSCTLGMAPPGEXTPARAMSTRINGDFLT sy-vline
WA_ICRSCTLGEOPANTP_STR-CRSCTLGMAPPGEXTPARAMDATEVALUE sy-vline
WA_ICRSCTLGEOPANTP_STR-CRSCTLGMAPPGEXTPARAMDTEDFLTVAL sy-vline
WA_ICRSCTLGEOPANTP_STR-BRFFUNCTIONUUID sy-vline
WA_ICRSCTLGEOPANTP_STR-CRSCTLGMAPPGEXTPARAMISMAND sy-vline
WA_ICRSCTLGEOPANTP_STR-CHARACTERISTIC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.