ABAP Select data from SAP table ICS_ITEMEQ into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ICS_ITEMEQ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ICS_ITEMEQ. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ICS_ITEMEQ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ICS_ITEMEQ TYPE STANDARD TABLE OF ICS_ITEMEQ, WA_ICS_ITEMEQ TYPE ICS_ITEMEQ, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ICS_ITEMEQ> TYPE ICS_ITEMEQ. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ICS_ITEMEQ. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ICS_ITEMEQ INTO TABLE IT_ICS_ITEMEQ. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ICS_ITEMEQ * INTO TABLE @DATA(IT_ICS_ITEMEQ2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ICS_ITEMEQ INDEX 1 INTO DATA(WA_ICS_ITEMEQ2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ICS_ITEMEQ ASSIGNING <ICS_ITEMEQ>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ICS_ITEMEQ>-MAKE = 1.
<ICS_ITEMEQ>-MODEL = 1.
<ICS_ITEMEQ>-CONSTYEAR = 1.
<ICS_ITEMEQ>-SERIALNO = 1.
<ICS_ITEMEQ>-LOCATION = 1.
ENDLOOP. LOOP AT IT_ICS_ITEMEQ INTO WA_ICS_ITEMEQ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ICS_ITEMEQ-LOSSTYPE, sy-vline,
WA_ICS_ITEMEQ-PROPUSE, sy-vline,
WA_ICS_ITEMEQ-XDAMAGED, sy-vline,
WA_ICS_ITEMEQ-XRECOVERED, sy-vline,
WA_ICS_ITEMEQ-XPVENDOR, sy-vline,
WA_ICS_ITEMEQ-XSTOLEN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ICS_ITEMEQ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ICS_ITEMEQ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ICS_ITEMEQ INTO WA_ICS_ITEMEQ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field LOCATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ICS_ITEMEQ-LOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ICS_ITEMEQ-LOCATION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ICS_ITEMEQ_STR,
MAKE TYPE STRING,
MODEL TYPE STRING,
CONSTYEAR TYPE STRING,
SERIALNO TYPE STRING,
LOCATION TYPE STRING,
LOSSTYPE TYPE STRING,
PROPUSE TYPE STRING,
XDAMAGED TYPE STRING,
XRECOVERED TYPE STRING,
XPVENDOR TYPE STRING,
XSTOLEN TYPE STRING,
XRENTAL TYPE STRING,
OPERABLE TYPE STRING,
ESTREPAIRDATE TYPE STRING,
ACTREPAIRDATE TYPE STRING,
WHENSEEN TYPE STRING,
XTOTDAMAGE TYPE STRING,
XOWNERRET TYPE STRING,
EVALDATE TYPE STRING,
DETERMDATE TYPE STRING,
ESTACV TYPE STRING,
SALVVALUE TYPE STRING,
CURR TYPE STRING,
HISTRATE TYPE STRING,
ASSIGNDATE TYPE STRING,
RETRVDATE TYPE STRING,
SETTLEDATE TYPE STRING,
SOLDDATE TYPE STRING,
TITLERECV TYPE STRING,
NOTE TYPE STRING,
SEL_LOCATION TYPE STRING,END OF T_EKKO_STR. DATA: WA_ICS_ITEMEQ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ICS_ITEMEQ_STR-MAKE sy-vline
WA_ICS_ITEMEQ_STR-MODEL sy-vline
WA_ICS_ITEMEQ_STR-CONSTYEAR sy-vline
WA_ICS_ITEMEQ_STR-SERIALNO sy-vline
WA_ICS_ITEMEQ_STR-LOCATION sy-vline
WA_ICS_ITEMEQ_STR-LOSSTYPE sy-vline
WA_ICS_ITEMEQ_STR-PROPUSE sy-vline
WA_ICS_ITEMEQ_STR-XDAMAGED sy-vline
WA_ICS_ITEMEQ_STR-XRECOVERED sy-vline
WA_ICS_ITEMEQ_STR-XPVENDOR sy-vline
WA_ICS_ITEMEQ_STR-XSTOLEN sy-vline
WA_ICS_ITEMEQ_STR-XRENTAL sy-vline
WA_ICS_ITEMEQ_STR-OPERABLE sy-vline
WA_ICS_ITEMEQ_STR-ESTREPAIRDATE sy-vline
WA_ICS_ITEMEQ_STR-ACTREPAIRDATE sy-vline
WA_ICS_ITEMEQ_STR-WHENSEEN sy-vline
WA_ICS_ITEMEQ_STR-XTOTDAMAGE sy-vline
WA_ICS_ITEMEQ_STR-XOWNERRET sy-vline
WA_ICS_ITEMEQ_STR-EVALDATE sy-vline
WA_ICS_ITEMEQ_STR-DETERMDATE sy-vline
WA_ICS_ITEMEQ_STR-ESTACV sy-vline
WA_ICS_ITEMEQ_STR-SALVVALUE sy-vline
WA_ICS_ITEMEQ_STR-CURR sy-vline
WA_ICS_ITEMEQ_STR-HISTRATE sy-vline
WA_ICS_ITEMEQ_STR-ASSIGNDATE sy-vline
WA_ICS_ITEMEQ_STR-RETRVDATE sy-vline
WA_ICS_ITEMEQ_STR-SETTLEDATE sy-vline
WA_ICS_ITEMEQ_STR-SOLDDATE sy-vline
WA_ICS_ITEMEQ_STR-TITLERECV sy-vline
WA_ICS_ITEMEQ_STR-NOTE sy-vline
WA_ICS_ITEMEQ_STR-SEL_LOCATION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.