ABAP Select data from SAP table IHSSFSIDR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IHSSFSIDR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IHSSFSIDR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IHSSFSIDR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IHSSFSIDR TYPE STANDARD TABLE OF IHSSFSIDR,
      WA_IHSSFSIDR TYPE IHSSFSIDR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IHSSFSIDR> TYPE IHSSFSIDR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IHSSFSIDR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IHSSFSIDR
  INTO TABLE IT_IHSSFSIDR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IHSSFSIDR
*  INTO TABLE @DATA(IT_IHSSFSIDR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IHSSFSIDR INDEX 1 INTO DATA(WA_IHSSFSIDR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IHSSFSIDR ASSIGNING <IHSSFSIDR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IHSSFSIDR>-MANDT = 1.
<IHSSFSIDR>-SAFETYINSTRUCTIONUUID = 1.
<IHSSFSIDR>-SAFETYINSTRUCTION = 1.
<IHSSFSIDR>-SAFETYINSTRUCTIONSTATUS = 1.
<IHSSFSIDR>-SAFETYINSTRUCTIONMAJORREVISION = 1.
ENDLOOP.

LOOP AT IT_IHSSFSIDR INTO WA_IHSSFSIDR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IHSSFSIDR-SAFETYINSTRUCTIONMINORREVISION, sy-vline,
WA_IHSSFSIDR-FACTORYEHSLOCATIONUUID, sy-vline,
WA_IHSSFSIDR-CHEMICALUUID, sy-vline,
WA_IHSSFSIDR-CHMLCMPLNCINFOUUID, sy-vline,
WA_IHSSFSIDR-JOBFREETEXT, sy-vline,
WA_IHSSFSIDR-FACTORYAREAFREETEXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IHSSFSIDR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IHSSFSIDR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IHSSFSIDR INTO WA_IHSSFSIDR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SAFETYINSTRUCTION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IHSSFSIDR-SAFETYINSTRUCTION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IHSSFSIDR-SAFETYINSTRUCTION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGUAGE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_IHSSFSIDR-LANGUAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IHSSFSIDR-LANGUAGE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IHSSFSIDR_STR,
MANDT TYPE STRING,
SAFETYINSTRUCTIONUUID TYPE STRING,
SAFETYINSTRUCTION TYPE STRING,
SAFETYINSTRUCTIONSTATUS TYPE STRING,
SAFETYINSTRUCTIONMAJORREVISION TYPE STRING,
SAFETYINSTRUCTIONMINORREVISION TYPE STRING,
FACTORYEHSLOCATIONUUID TYPE STRING,
CHEMICALUUID TYPE STRING,
CHMLCMPLNCINFOUUID TYPE STRING,
JOBFREETEXT TYPE STRING,
FACTORYAREAFREETEXT TYPE STRING,
LANGUAGE TYPE STRING,
SAFETYINSTRUCTIONRELDATE TYPE STRING,
ACTIVESAFETYINSTRUCTIONUUID TYPE STRING,
SAFETYINSTRUCTIONTYPE TYPE STRING,
SAFETYINSTRUCTIONSUBTYPE TYPE STRING,
SAFETYINSTRUCTIONSUBJECTDESC TYPE STRING,END OF T_EKKO_STR. DATA: WA_IHSSFSIDR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IHSSFSIDR_STR-MANDT sy-vline
WA_IHSSFSIDR_STR-SAFETYINSTRUCTIONUUID sy-vline
WA_IHSSFSIDR_STR-SAFETYINSTRUCTION sy-vline
WA_IHSSFSIDR_STR-SAFETYINSTRUCTIONSTATUS sy-vline
WA_IHSSFSIDR_STR-SAFETYINSTRUCTIONMAJORREVISION sy-vline
WA_IHSSFSIDR_STR-SAFETYINSTRUCTIONMINORREVISION sy-vline
WA_IHSSFSIDR_STR-FACTORYEHSLOCATIONUUID sy-vline
WA_IHSSFSIDR_STR-CHEMICALUUID sy-vline
WA_IHSSFSIDR_STR-CHMLCMPLNCINFOUUID sy-vline
WA_IHSSFSIDR_STR-JOBFREETEXT sy-vline
WA_IHSSFSIDR_STR-FACTORYAREAFREETEXT sy-vline
WA_IHSSFSIDR_STR-LANGUAGE sy-vline
WA_IHSSFSIDR_STR-SAFETYINSTRUCTIONRELDATE sy-vline
WA_IHSSFSIDR_STR-ACTIVESAFETYINSTRUCTIONUUID sy-vline
WA_IHSSFSIDR_STR-SAFETYINSTRUCTIONTYPE sy-vline
WA_IHSSFSIDR_STR-SAFETYINSTRUCTIONSUBTYPE sy-vline
WA_IHSSFSIDR_STR-SAFETYINSTRUCTIONSUBJECTDESC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.