ABAP Select data from SAP table IINSPRSLTVALDVAL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IINSPRSLTVALDVAL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IINSPRSLTVALDVAL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IINSPRSLTVALDVAL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IINSPRSLTVALDVAL TYPE STANDARD TABLE OF IINSPRSLTVALDVAL,
      WA_IINSPRSLTVALDVAL TYPE IINSPRSLTVALDVAL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IINSPRSLTVALDVAL> TYPE IINSPRSLTVALDVAL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IINSPRSLTVALDVAL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IINSPRSLTVALDVAL
  INTO TABLE IT_IINSPRSLTVALDVAL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IINSPRSLTVALDVAL
*  INTO TABLE @DATA(IT_IINSPRSLTVALDVAL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IINSPRSLTVALDVAL INDEX 1 INTO DATA(WA_IINSPRSLTVALDVAL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IINSPRSLTVALDVAL ASSIGNING <IINSPRSLTVALDVAL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IINSPRSLTVALDVAL>-MANDT = 1.
<IINSPRSLTVALDVAL>-INSPECTIONLOT = 1.
<IINSPRSLTVALDVAL>-INSPPLANOPERATIONINTERNALID = 1.
<IINSPRSLTVALDVAL>-INSPECTIONCHARACTERISTIC = 1.
<IINSPRSLTVALDVAL>-INSPRESULTVALUEINTERNALID = 1.
ENDLOOP.

LOOP AT IT_IINSPRSLTVALDVAL INTO WA_IINSPRSLTVALDVAL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IINSPRSLTVALDVAL-INSPECTIONRESULTATTRIBUTE, sy-vline,
WA_IINSPRSLTVALDVAL-CREATIONDATE, sy-vline,
WA_IINSPRSLTVALDVAL-INSPRESULTITEMINTERNALID, sy-vline,
WA_IINSPRSLTVALDVAL-INSPECTIONSUBSETINTERNALID, sy-vline,
WA_IINSPRSLTVALDVAL-INSPECTIONRESULTMEASUREDVALUE, sy-vline,
WA_IINSPRSLTVALDVAL-INSPRESULTHASMEASUREDVALUE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IINSPRSLTVALDVAL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IINSPRSLTVALDVAL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IINSPRSLTVALDVAL INTO WA_IINSPRSLTVALDVAL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSPECTIONLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPRSLTVALDVAL-INSPECTIONLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPRSLTVALDVAL-INSPECTIONLOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONRESULTITEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPRSLTVALDVAL-INSPECTIONRESULTITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPRSLTVALDVAL-INSPECTIONRESULTITEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPRSLTFREEDEFINEDTESTEQUIP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPRSLTVALDVAL-INSPRSLTFREEDEFINEDTESTEQUIP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPRSLTVALDVAL-INSPRSLTFREEDEFINEDTESTEQUIP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IINSPRSLTVALDVAL_STR,
MANDT TYPE STRING,
INSPECTIONLOT TYPE STRING,
INSPPLANOPERATIONINTERNALID TYPE STRING,
INSPECTIONCHARACTERISTIC TYPE STRING,
INSPRESULTVALUEINTERNALID TYPE STRING,
INSPECTIONRESULTATTRIBUTE TYPE STRING,
CREATIONDATE TYPE STRING,
INSPRESULTITEMINTERNALID TYPE STRING,
INSPECTIONSUBSETINTERNALID TYPE STRING,
INSPECTIONRESULTMEASUREDVALUE TYPE STRING,
INSPRESULTHASMEASUREDVALUE TYPE STRING,
INSPECTIONRESULTORIGINALVALUE TYPE STRING,
INSPECTIONRESULTTEXT TYPE STRING,
INSPLOTSINGLEUNITNUMBER TYPE STRING,
INSPECTIONRESULTITEM TYPE STRING,
INSPRSLTFREEDEFINEDTESTEQUIP TYPE STRING,
INSPECTIONVALUATIONRESULT TYPE STRING,
CHARACTERISTICATTRIBUTECODEGRP TYPE STRING,
INSPECTIONRESULTCODEGROUP2 TYPE STRING,
INSPECTIONRESULTCODEGROUP3 TYPE STRING,
INSPECTIONRESULTCODEGROUP4 TYPE STRING,
INSPECTIONRESULTCODEGROUP5 TYPE STRING,
CHARACTERISTICATTRIBUTECODE TYPE STRING,
INSPECTIONRESULTCODE2 TYPE STRING,
INSPECTIONRESULTCODE3 TYPE STRING,
INSPECTIONRESULTCODE4 TYPE STRING,
INSPECTIONRESULTCODE5 TYPE STRING,
CHARACTERISTICATTRIBUTECATALOG TYPE STRING,
INSPECTIONRESULTCATALOG2 TYPE STRING,
INSPECTIONRESULTCATALOG3 TYPE STRING,
INSPECTIONRESULTCATALOG4 TYPE STRING,
INSPECTIONRESULTCATALOG5 TYPE STRING,
INSPECTIONSTARTDATE TYPE STRING,
INSPECTIONSTARTTIME TYPE STRING,
INSPECTIONENDDATE TYPE STRING,
INSPECTIONENDTIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_IINSPRSLTVALDVAL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IINSPRSLTVALDVAL_STR-MANDT sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONLOT sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPPLANOPERATIONINTERNALID sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONCHARACTERISTIC sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPRESULTVALUEINTERNALID sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTATTRIBUTE sy-vline
WA_IINSPRSLTVALDVAL_STR-CREATIONDATE sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPRESULTITEMINTERNALID sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONSUBSETINTERNALID sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTMEASUREDVALUE sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPRESULTHASMEASUREDVALUE sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTORIGINALVALUE sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTTEXT sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPLOTSINGLEUNITNUMBER sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTITEM sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPRSLTFREEDEFINEDTESTEQUIP sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONVALUATIONRESULT sy-vline
WA_IINSPRSLTVALDVAL_STR-CHARACTERISTICATTRIBUTECODEGRP sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTCODEGROUP2 sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTCODEGROUP3 sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTCODEGROUP4 sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTCODEGROUP5 sy-vline
WA_IINSPRSLTVALDVAL_STR-CHARACTERISTICATTRIBUTECODE sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTCODE2 sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTCODE3 sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTCODE4 sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTCODE5 sy-vline
WA_IINSPRSLTVALDVAL_STR-CHARACTERISTICATTRIBUTECATALOG sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTCATALOG2 sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTCATALOG3 sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTCATALOG4 sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONRESULTCATALOG5 sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONSTARTDATE sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONSTARTTIME sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONENDDATE sy-vline
WA_IINSPRSLTVALDVAL_STR-INSPECTIONENDTIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.