ABAP Select data from SAP table IINSPSUBSETCHAR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IINSPSUBSETCHAR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IINSPSUBSETCHAR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IINSPSUBSETCHAR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IINSPSUBSETCHAR TYPE STANDARD TABLE OF IINSPSUBSETCHAR,
      WA_IINSPSUBSETCHAR TYPE IINSPSUBSETCHAR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IINSPSUBSETCHAR> TYPE IINSPSUBSETCHAR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IINSPSUBSETCHAR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IINSPSUBSETCHAR
  INTO TABLE IT_IINSPSUBSETCHAR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IINSPSUBSETCHAR
*  INTO TABLE @DATA(IT_IINSPSUBSETCHAR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IINSPSUBSETCHAR INDEX 1 INTO DATA(WA_IINSPSUBSETCHAR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IINSPSUBSETCHAR ASSIGNING <IINSPSUBSETCHAR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IINSPSUBSETCHAR>-MANDT = 1.
<IINSPSUBSETCHAR>-INSPECTIONLOT = 1.
<IINSPSUBSETCHAR>-INSPPLANOPERATIONINTERNALID = 1.
<IINSPSUBSETCHAR>-INSPECTIONCHARACTERISTIC = 1.
<IINSPSUBSETCHAR>-INSPECTIONSUBSETINTERNALID = 1.
ENDLOOP.

LOOP AT IT_IINSPSUBSETCHAR INTO WA_IINSPSUBSETCHAR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IINSPSUBSETCHAR-INSPECTIONCHARACTERISTICSTATUS, sy-vline,
WA_IINSPSUBSETCHAR-QUALITYCONTROLCHART, sy-vline,
WA_IINSPSUBSETCHAR-INSPSAMPLEACCEPTANCENUMBER, sy-vline,
WA_IINSPSUBSETCHAR-INSPSAMPLEREJECTIONNUMBER, sy-vline,
WA_IINSPSUBSETCHAR-INSPSAMPLEVALUATIONRULE, sy-vline,
WA_IINSPSUBSETCHAR-INSPECTIONSAMPLESIZE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IINSPSUBSETCHAR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IINSPSUBSETCHAR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IINSPSUBSETCHAR INTO WA_IINSPSUBSETCHAR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSPECTIONLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPSUBSETCHAR-INSPECTIONLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPSUBSETCHAR-INSPECTIONLOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QUALITYCONTROLCHART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IINSPSUBSETCHAR-QUALITYCONTROLCHART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPSUBSETCHAR-QUALITYCONTROLCHART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field INSPCHARACTERISTICSAMPLEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IINSPSUBSETCHAR-INSPCHARACTERISTICSAMPLEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IINSPSUBSETCHAR-INSPCHARACTERISTICSAMPLEUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IINSPSUBSETCHAR_STR,
MANDT TYPE STRING,
INSPECTIONLOT TYPE STRING,
INSPPLANOPERATIONINTERNALID TYPE STRING,
INSPECTIONCHARACTERISTIC TYPE STRING,
INSPECTIONSUBSETINTERNALID TYPE STRING,
INSPECTIONCHARACTERISTICSTATUS TYPE STRING,
QUALITYCONTROLCHART TYPE STRING,
INSPSAMPLEACCEPTANCENUMBER TYPE STRING,
INSPSAMPLEREJECTIONNUMBER TYPE STRING,
INSPSAMPLEVALUATIONRULE TYPE STRING,
INSPECTIONSAMPLESIZE TYPE STRING,
INSPCHARACTERISTICSAMPLEUNIT TYPE STRING,
INSPSPECSAMPLEQUANTITYFACTOR TYPE STRING,
INSPLOTDYNRULESTAGE TYPE STRING,
INSPECTIONSEVERITY TYPE STRING,
INSPSUBSETCHARCCREATIONDATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_IINSPSUBSETCHAR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IINSPSUBSETCHAR_STR-MANDT sy-vline
WA_IINSPSUBSETCHAR_STR-INSPECTIONLOT sy-vline
WA_IINSPSUBSETCHAR_STR-INSPPLANOPERATIONINTERNALID sy-vline
WA_IINSPSUBSETCHAR_STR-INSPECTIONCHARACTERISTIC sy-vline
WA_IINSPSUBSETCHAR_STR-INSPECTIONSUBSETINTERNALID sy-vline
WA_IINSPSUBSETCHAR_STR-INSPECTIONCHARACTERISTICSTATUS sy-vline
WA_IINSPSUBSETCHAR_STR-QUALITYCONTROLCHART sy-vline
WA_IINSPSUBSETCHAR_STR-INSPSAMPLEACCEPTANCENUMBER sy-vline
WA_IINSPSUBSETCHAR_STR-INSPSAMPLEREJECTIONNUMBER sy-vline
WA_IINSPSUBSETCHAR_STR-INSPSAMPLEVALUATIONRULE sy-vline
WA_IINSPSUBSETCHAR_STR-INSPECTIONSAMPLESIZE sy-vline
WA_IINSPSUBSETCHAR_STR-INSPCHARACTERISTICSAMPLEUNIT sy-vline
WA_IINSPSUBSETCHAR_STR-INSPSPECSAMPLEQUANTITYFACTOR sy-vline
WA_IINSPSUBSETCHAR_STR-INSPLOTDYNRULESTAGE sy-vline
WA_IINSPSUBSETCHAR_STR-INSPECTIONSEVERITY sy-vline
WA_IINSPSUBSETCHAR_STR-INSPSUBSETCHARCCREATIONDATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.