ABAP Select data from SAP table IIPPRTTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IIPPRTTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IIPPRTTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IIPPRTTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IIPPRTTP TYPE STANDARD TABLE OF IIPPRTTP,
      WA_IIPPRTTP TYPE IIPPRTTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IIPPRTTP> TYPE IIPPRTTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IIPPRTTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IIPPRTTP
  INTO TABLE IT_IIPPRTTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IIPPRTTP
*  INTO TABLE @DATA(IT_IIPPRTTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IIPPRTTP INDEX 1 INTO DATA(WA_IIPPRTTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IIPPRTTP ASSIGNING <IIPPRTTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IIPPRTTP>-MANDT = 1.
<IIPPRTTP>-INSPECTIONPLANGROUP = 1.
<IIPPRTTP>-INSPECTIONPLAN = 1.
<IIPPRTTP>-INSPECTIONPLANINTERNALVERSION = 1.
<IIPPRTTP>-BOOOPERATIONINTERNALID = 1.
ENDLOOP.

LOOP AT IT_IIPPRTTP INTO WA_IIPPRTTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IIPPRTTP-BOOOPINTERNALVERSIONCOUNTER, sy-vline,
WA_IIPPRTTP-BOOOPERATIONPRTINTERNALID, sy-vline,
WA_IIPPRTTP-BILLOFOPERATIONSTYPE, sy-vline,
WA_IIPPRTTP-BILLOFOPERATIONSSEQUENCE, sy-vline,
WA_IIPPRTTP-OPERATIONTEXT, sy-vline,
WA_IIPPRTTP-BILLOFOPERATIONSDESC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IIPPRTTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IIPPRTTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IIPPRTTP INTO WA_IIPPRTTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INSPECTIONPLANGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IIPPRTTP-INSPECTIONPLANGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IIPPRTTP-INSPECTIONPLANGROUP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPECTIONPLAN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IIPPRTTP-INSPECTIONPLAN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IIPPRTTP-INSPECTIONPLAN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BILLOFOPERATIONSSEQUENCE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IIPPRTTP-BILLOFOPERATIONSSEQUENCE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IIPPRTTP-BILLOFOPERATIONSSEQUENCE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CHANGENUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IIPPRTTP-CHANGENUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IIPPRTTP-CHANGENUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRODNRSCETOOLSTDWORKQTYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IIPPRTTP-PRODNRSCETOOLSTDWORKQTYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IIPPRTTP-PRODNRSCETOOLSTDWORKQTYUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRODNRSCETOOLUSAGEQUANTITYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IIPPRTTP-PRODNRSCETOOLUSAGEQUANTITYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IIPPRTTP-PRODNRSCETOOLUSAGEQUANTITYUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field STARTDATEOFFSETDURATIONUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IIPPRTTP-STARTDATEOFFSETDURATIONUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IIPPRTTP-STARTDATEOFFSETDURATIONUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ENDDATEOFFSETDURATIONUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IIPPRTTP-ENDDATEOFFSETDURATIONUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IIPPRTTP-ENDDATEOFFSETDURATIONUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BILLOFOPERATIONSVERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IIPPRTTP-BILLOFOPERATIONSVERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IIPPRTTP-BILLOFOPERATIONSVERSION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IIPPRTTP_STR,
MANDT TYPE STRING,
INSPECTIONPLANGROUP TYPE STRING,
INSPECTIONPLAN TYPE STRING,
INSPECTIONPLANINTERNALVERSION TYPE STRING,
BOOOPERATIONINTERNALID TYPE STRING,
BOOOPINTERNALVERSIONCOUNTER TYPE STRING,
BOOOPERATIONPRTINTERNALID TYPE STRING,
BILLOFOPERATIONSTYPE TYPE STRING,
BILLOFOPERATIONSSEQUENCE TYPE STRING,
OPERATIONTEXT TYPE STRING,
BILLOFOPERATIONSDESC TYPE STRING,
PRODUCTIONRESOURCETYPE TYPE STRING,
PRODUCTIONRESOURCEINTERNALID TYPE STRING,
PRODNRSCETOOLCATEGORYNAME TYPE STRING,
PRODUCTIONRESOURCETOOL TYPE STRING,
PRODUCTIONRESOURCETOOLDESC TYPE STRING,
VALIDITYSTARTDATE TYPE STRING,
VALIDITYENDDATE TYPE STRING,
CHANGENUMBER TYPE STRING,
PRODNRSCETOOLITEMNUMBER TYPE STRING,
PRODNRSCETOOLCONTROLPROFILE TYPE STRING,
PRODNRSCETOOLSTANDARDTEXTCODE TYPE STRING,
PRODNRSCETOOLTEXT TYPE STRING,
CREATIONDATE TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEDATE TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
ISDELETED TYPE STRING,
ISIMPLICITLYDELETED TYPE STRING,
PRODNRSCETOOLSTDWORKQTYUNIT TYPE STRING,
PRODNRSCETOOLSTANDARDWORKQTY TYPE STRING,
PRODNRSCETOOLTOTQTYCALCFORMULA TYPE STRING,
PRODNRSCETOOLUSAGEQUANTITYUNIT TYPE STRING,
PRODNRSCETOOLUSAGEQUANTITY TYPE STRING,
PRODNRSCETOOLUSAGEQTYCALCFMLA TYPE STRING,
STARTDATEOFFSETREFERENCECODE TYPE STRING,
STARTDATEOFFSETDURATIONUNIT TYPE STRING,
STARTDATEOFFSETDURATION TYPE STRING,
ENDDATEOFFSETREFERENCECODE TYPE STRING,
ENDDATEOFFSETDURATIONUNIT TYPE STRING,
ENDDATEOFFSETDURATION TYPE STRING,
BILLOFOPERATIONSVERSION TYPE STRING,END OF T_EKKO_STR. DATA: WA_IIPPRTTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IIPPRTTP_STR-MANDT sy-vline
WA_IIPPRTTP_STR-INSPECTIONPLANGROUP sy-vline
WA_IIPPRTTP_STR-INSPECTIONPLAN sy-vline
WA_IIPPRTTP_STR-INSPECTIONPLANINTERNALVERSION sy-vline
WA_IIPPRTTP_STR-BOOOPERATIONINTERNALID sy-vline
WA_IIPPRTTP_STR-BOOOPINTERNALVERSIONCOUNTER sy-vline
WA_IIPPRTTP_STR-BOOOPERATIONPRTINTERNALID sy-vline
WA_IIPPRTTP_STR-BILLOFOPERATIONSTYPE sy-vline
WA_IIPPRTTP_STR-BILLOFOPERATIONSSEQUENCE sy-vline
WA_IIPPRTTP_STR-OPERATIONTEXT sy-vline
WA_IIPPRTTP_STR-BILLOFOPERATIONSDESC sy-vline
WA_IIPPRTTP_STR-PRODUCTIONRESOURCETYPE sy-vline
WA_IIPPRTTP_STR-PRODUCTIONRESOURCEINTERNALID sy-vline
WA_IIPPRTTP_STR-PRODNRSCETOOLCATEGORYNAME sy-vline
WA_IIPPRTTP_STR-PRODUCTIONRESOURCETOOL sy-vline
WA_IIPPRTTP_STR-PRODUCTIONRESOURCETOOLDESC sy-vline
WA_IIPPRTTP_STR-VALIDITYSTARTDATE sy-vline
WA_IIPPRTTP_STR-VALIDITYENDDATE sy-vline
WA_IIPPRTTP_STR-CHANGENUMBER sy-vline
WA_IIPPRTTP_STR-PRODNRSCETOOLITEMNUMBER sy-vline
WA_IIPPRTTP_STR-PRODNRSCETOOLCONTROLPROFILE sy-vline
WA_IIPPRTTP_STR-PRODNRSCETOOLSTANDARDTEXTCODE sy-vline
WA_IIPPRTTP_STR-PRODNRSCETOOLTEXT sy-vline
WA_IIPPRTTP_STR-CREATIONDATE sy-vline
WA_IIPPRTTP_STR-CREATEDBYUSER sy-vline
WA_IIPPRTTP_STR-LASTCHANGEDATE sy-vline
WA_IIPPRTTP_STR-LASTCHANGEDBYUSER sy-vline
WA_IIPPRTTP_STR-ISDELETED sy-vline
WA_IIPPRTTP_STR-ISIMPLICITLYDELETED sy-vline
WA_IIPPRTTP_STR-PRODNRSCETOOLSTDWORKQTYUNIT sy-vline
WA_IIPPRTTP_STR-PRODNRSCETOOLSTANDARDWORKQTY sy-vline
WA_IIPPRTTP_STR-PRODNRSCETOOLTOTQTYCALCFORMULA sy-vline
WA_IIPPRTTP_STR-PRODNRSCETOOLUSAGEQUANTITYUNIT sy-vline
WA_IIPPRTTP_STR-PRODNRSCETOOLUSAGEQUANTITY sy-vline
WA_IIPPRTTP_STR-PRODNRSCETOOLUSAGEQTYCALCFMLA sy-vline
WA_IIPPRTTP_STR-STARTDATEOFFSETREFERENCECODE sy-vline
WA_IIPPRTTP_STR-STARTDATEOFFSETDURATIONUNIT sy-vline
WA_IIPPRTTP_STR-STARTDATEOFFSETDURATION sy-vline
WA_IIPPRTTP_STR-ENDDATEOFFSETREFERENCECODE sy-vline
WA_IIPPRTTP_STR-ENDDATEOFFSETDURATIONUNIT sy-vline
WA_IIPPRTTP_STR-ENDDATEOFFSETDURATION sy-vline
WA_IIPPRTTP_STR-BILLOFOPERATIONSVERSION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.