ABAP Select data from SAP table IMAINTITEMFLSTR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP IMAINTITEMFLSTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IMAINTITEMFLSTR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the IMAINTITEMFLSTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_IMAINTITEMFLSTR TYPE STANDARD TABLE OF IMAINTITEMFLSTR, WA_IMAINTITEMFLSTR TYPE IMAINTITEMFLSTR, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <IMAINTITEMFLSTR> TYPE IMAINTITEMFLSTR. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_IMAINTITEMFLSTR. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM IMAINTITEMFLSTR INTO TABLE IT_IMAINTITEMFLSTR. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM IMAINTITEMFLSTR * INTO TABLE @DATA(IT_IMAINTITEMFLSTR2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_IMAINTITEMFLSTR INDEX 1 INTO DATA(WA_IMAINTITEMFLSTR2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_IMAINTITEMFLSTR ASSIGNING <IMAINTITEMFLSTR>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<IMAINTITEMFLSTR>-MANDT = 1.
<IMAINTITEMFLSTR>-DFSMAINTFUNCTIONALLOCATION = 1.
<IMAINTITEMFLSTR>-EQUIPMENT = 1.
<IMAINTITEMFLSTR>-MAINTENANCEITEM = 1.
<IMAINTITEMFLSTR>-MAINTENANCECALLNEXTPLANNEDDATE = 1.
ENDLOOP. LOOP AT IT_IMAINTITEMFLSTR INTO WA_IMAINTITEMFLSTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_IMAINTITEMFLSTR-MAINTENANCECALL, sy-vline,
WA_IMAINTITEMFLSTR-MAINTENANCEPLAN, sy-vline,
WA_IMAINTITEMFLSTR-MAINTENANCEPLANDESC, sy-vline,
WA_IMAINTITEMFLSTR-EQUIPMENTNAME, sy-vline,
WA_IMAINTITEMFLSTR-FUNCTIONALLOCATIONNAME, sy-vline,
WA_IMAINTITEMFLSTR-MAINTENANCEITEMDESCRIPTION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IMAINTITEMFLSTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IMAINTITEMFLSTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IMAINTITEMFLSTR INTO WA_IMAINTITEMFLSTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit TPLNR, internal->external for field DFSMAINTFUNCTIONALLOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_IMAINTITEMFLSTR-DFSMAINTFUNCTIONALLOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMAINTITEMFLSTR-DFSMAINTFUNCTIONALLOCATION.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IMAINTITEMFLSTR-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMAINTITEMFLSTR-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MEASUREMENTRANGEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IMAINTITEMFLSTR-MEASUREMENTRANGEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMAINTITEMFLSTR-MEASUREMENTRANGEUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IMAINTITEMFLSTR_STR,
MANDT TYPE STRING,
DFSMAINTFUNCTIONALLOCATION TYPE STRING,
EQUIPMENT TYPE STRING,
MAINTENANCEITEM TYPE STRING,
MAINTENANCECALLNEXTPLANNEDDATE TYPE STRING,
MAINTENANCECALL TYPE STRING,
MAINTENANCEPLAN TYPE STRING,
MAINTENANCEPLANDESC TYPE STRING,
EQUIPMENTNAME TYPE STRING,
FUNCTIONALLOCATIONNAME TYPE STRING,
MAINTENANCEITEMDESCRIPTION TYPE STRING,
MEASURINGPOINT TYPE STRING,
MAINTENANCEPLANNINGPLANT TYPE STRING,
MAINWORKCENTERINTERNALID TYPE STRING,
MAINTENANCEPACKAGE TYPE STRING,
CURRENTDATE TYPE STRING,
MEASUREMENTRANGEUNIT TYPE STRING,
DFSMAINTMSMTRMNGDAYSVALUE TYPE STRING,
DFSMAINTEXPLOSIONTYPE TYPE STRING,
DFSMAINTEQUIPMENTUTILIZERID TYPE STRING,
UNITOFMEASURETECHNICALNAME TYPE STRING,
SIUNITCNVRSNRATEDENOMINATOR TYPE STRING,
SIUNITCNVRSNRATENUMERATOR TYPE STRING,
BASICSTARTDATE TYPE STRING,
CREATEDBYUSER TYPE STRING,
CREATIONDATE TYPE STRING,
DFSMAINTMSMTRMNGRDNGSVALUE TYPE STRING,
MAINTCALLNEXTPLNDCNTRRDNG TYPE STRING,
MAINTPLANFREEDEFINEDATTRIB TYPE STRING,
TECHOBJECTWITHLEADINGZEROS TYPE STRING,END OF T_EKKO_STR. DATA: WA_IMAINTITEMFLSTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IMAINTITEMFLSTR_STR-MANDT sy-vline
WA_IMAINTITEMFLSTR_STR-DFSMAINTFUNCTIONALLOCATION sy-vline
WA_IMAINTITEMFLSTR_STR-EQUIPMENT sy-vline
WA_IMAINTITEMFLSTR_STR-MAINTENANCEITEM sy-vline
WA_IMAINTITEMFLSTR_STR-MAINTENANCECALLNEXTPLANNEDDATE sy-vline
WA_IMAINTITEMFLSTR_STR-MAINTENANCECALL sy-vline
WA_IMAINTITEMFLSTR_STR-MAINTENANCEPLAN sy-vline
WA_IMAINTITEMFLSTR_STR-MAINTENANCEPLANDESC sy-vline
WA_IMAINTITEMFLSTR_STR-EQUIPMENTNAME sy-vline
WA_IMAINTITEMFLSTR_STR-FUNCTIONALLOCATIONNAME sy-vline
WA_IMAINTITEMFLSTR_STR-MAINTENANCEITEMDESCRIPTION sy-vline
WA_IMAINTITEMFLSTR_STR-MEASURINGPOINT sy-vline
WA_IMAINTITEMFLSTR_STR-MAINTENANCEPLANNINGPLANT sy-vline
WA_IMAINTITEMFLSTR_STR-MAINWORKCENTERINTERNALID sy-vline
WA_IMAINTITEMFLSTR_STR-MAINTENANCEPACKAGE sy-vline
WA_IMAINTITEMFLSTR_STR-CURRENTDATE sy-vline
WA_IMAINTITEMFLSTR_STR-MEASUREMENTRANGEUNIT sy-vline
WA_IMAINTITEMFLSTR_STR-DFSMAINTMSMTRMNGDAYSVALUE sy-vline
WA_IMAINTITEMFLSTR_STR-DFSMAINTEXPLOSIONTYPE sy-vline
WA_IMAINTITEMFLSTR_STR-DFSMAINTEQUIPMENTUTILIZERID sy-vline
WA_IMAINTITEMFLSTR_STR-UNITOFMEASURETECHNICALNAME sy-vline
WA_IMAINTITEMFLSTR_STR-SIUNITCNVRSNRATEDENOMINATOR sy-vline
WA_IMAINTITEMFLSTR_STR-SIUNITCNVRSNRATENUMERATOR sy-vline
WA_IMAINTITEMFLSTR_STR-BASICSTARTDATE sy-vline
WA_IMAINTITEMFLSTR_STR-CREATEDBYUSER sy-vline
WA_IMAINTITEMFLSTR_STR-CREATIONDATE sy-vline
WA_IMAINTITEMFLSTR_STR-DFSMAINTMSMTRMNGRDNGSVALUE sy-vline
WA_IMAINTITEMFLSTR_STR-MAINTCALLNEXTPLNDCNTRRDNG sy-vline
WA_IMAINTITEMFLSTR_STR-MAINTPLANFREEDEFINEDATTRIB sy-vline
WA_IMAINTITEMFLSTR_STR-TECHOBJECTWITHLEADINGZEROS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.