ABAP Select data from SAP table IMNTORDTOCUBE into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP IMNTORDTOCUBE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IMNTORDTOCUBE. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the IMNTORDTOCUBE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_IMNTORDTOCUBE TYPE STANDARD TABLE OF IMNTORDTOCUBE, WA_IMNTORDTOCUBE TYPE IMNTORDTOCUBE, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <IMNTORDTOCUBE> TYPE IMNTORDTOCUBE. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_IMNTORDTOCUBE. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM IMNTORDTOCUBE INTO TABLE IT_IMNTORDTOCUBE. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM IMNTORDTOCUBE * INTO TABLE @DATA(IT_IMNTORDTOCUBE2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_IMNTORDTOCUBE INDEX 1 INTO DATA(WA_IMNTORDTOCUBE2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_IMNTORDTOCUBE ASSIGNING <IMNTORDTOCUBE>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<IMNTORDTOCUBE>-MANDT = 1.
<IMNTORDTOCUBE>-MAINTENANCEORDER = 1.
<IMNTORDTOCUBE>-MAINTENANCEORDERISHISTORICAL = 1.
<IMNTORDTOCUBE>-MAINTENANCEORDERTYPE = 1.
<IMNTORDTOCUBE>-MAINTENANCEORDERDESC = 1.
ENDLOOP. LOOP AT IT_IMNTORDTOCUBE INTO WA_IMNTORDTOCUBE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_IMNTORDTOCUBE-MAINTPRIORITY, sy-vline,
WA_IMNTORDTOCUBE-MAINTPRIORITYTYPE, sy-vline,
WA_IMNTORDTOCUBE-FUNCTIONALLOCATION, sy-vline,
WA_IMNTORDTOCUBE-EQUIPMENT, sy-vline,
WA_IMNTORDTOCUBE-ASSEMBLY, sy-vline,
WA_IMNTORDTOCUBE-MATERIAL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IMNTORDTOCUBE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IMNTORDTOCUBE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IMNTORDTOCUBE INTO WA_IMNTORDTOCUBE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field MAINTENANCEORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-MAINTENANCEORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-MAINTENANCEORDER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TPLNR, internal->external for field FUNCTIONALLOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-FUNCTIONALLOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-FUNCTIONALLOCATION.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field ASSEMBLY CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-ASSEMBLY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-ASSEMBLY.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-MATERIAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GERNR, internal->external for field SERIALNUMBER CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-SERIALNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-SERIALNUMBER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field MAINTENANCENOTIFICATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-MAINTENANCENOTIFICATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-MAINTENANCENOTIFICATION.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LEADINGORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-LEADINGORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-LEADINGORDER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field MAINTORDPERSONRESPONSIBLE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-MAINTORDPERSONRESPONSIBLE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-MAINTORDPERSONRESPONSIBLE.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field MAINTENANCEPLAN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-MAINTENANCEPLAN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-MAINTENANCEPLAN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field MAINTENANCEITEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-MAINTENANCEITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-MAINTENANCEITEM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field TASKLISTGROUP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-TASKLISTGROUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-TASKLISTGROUP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field TASKLISTGROUPCOUNTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-TASKLISTGROUPCOUNTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-TASKLISTGROUPCOUNTER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field COSTCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-COSTCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-COSTCENTER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SUPERIORPROJECTNETWORK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-SUPERIORPROJECTNETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-SUPERIORPROJECTNETWORK.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ABPSP, internal->external for field WBSELEMENTINTERNALID CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-WBSELEMENTINTERNALID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-WBSELEMENTINTERNALID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field MASTERFIXEDASSET CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-MASTERFIXEDASSET IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-MASTERFIXEDASSET.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field FIXEDASSET CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-FIXEDASSET IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-FIXEDASSET.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SETTLEMENTORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-SETTLEMENTORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-SETTLEMENTORDER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ORDERDURATIONUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IMNTORDTOCUBE-ORDERDURATIONUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IMNTORDTOCUBE-ORDERDURATIONUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IMNTORDTOCUBE_STR,
MANDT TYPE STRING,
MAINTENANCEORDER TYPE STRING,
MAINTENANCEORDERISHISTORICAL TYPE STRING,
MAINTENANCEORDERTYPE TYPE STRING,
MAINTENANCEORDERDESC TYPE STRING,
MAINTPRIORITY TYPE STRING,
MAINTPRIORITYTYPE TYPE STRING,
FUNCTIONALLOCATION TYPE STRING,
EQUIPMENT TYPE STRING,
ASSEMBLY TYPE STRING,
MATERIAL TYPE STRING,
SERIALNUMBER TYPE STRING,
MAINTENANCENOTIFICATION TYPE STRING,
LEADINGORDER TYPE STRING,
MAINTENANCEPLANNERGROUP TYPE STRING,
MAINTENANCEPLANNINGPLANT TYPE STRING,
MAINTORDPERSONRESPONSIBLE TYPE STRING,
MAINTENANCEREVISION TYPE STRING,
MAINTENANCEPLAN TYPE STRING,
MAINTENANCEITEM TYPE STRING,
TASKLISTTYPE TYPE STRING,
TASKLISTGROUP TYPE STRING,
TASKLISTGROUPCOUNTER TYPE STRING,
MAINTENANCEORDERPLANNINGCODE TYPE STRING,
MAINTENANCEACTIVITYTYPE TYPE STRING,
ABCINDICATOR TYPE STRING,
MAINTENANCEPLANT TYPE STRING,
ASSETLOCATION TYPE STRING,
ASSETROOM TYPE STRING,
MAINTENANCEPROCESSINGPHASE TYPE STRING,
OPERATIONSYSTEMCONDITION TYPE STRING,
PLANTSECTION TYPE STRING,
MAINWORKCENTER TYPE STRING,
MAINWORKCENTERPLANT TYPE STRING,
WORKCENTER TYPE STRING,
WORKCENTERPLANT TYPE STRING,
REFERENCEELEMENT TYPE STRING,
COSTCENTER TYPE STRING,
CONTROLLINGAREA TYPE STRING,
SUPERIORPROJECTNETWORK TYPE STRING,
COMPANYCODE TYPE STRING,
BUSINESSAREA TYPE STRING,
WBSELEMENTINTERNALID TYPE STRING,
MASTERFIXEDASSET TYPE STRING,
FIXEDASSET TYPE STRING,
SETTLEMENTORDER TYPE STRING,
MAINTENANCEORDERINTERNALID TYPE STRING,
ISMARKEDFORDELETION TYPE STRING,
CREATIONDATE TYPE STRING,
CREATIONTIME TYPE STRING,
LASTCHANGEDATE TYPE STRING,
LASTCHANGETIME TYPE STRING,
PLANNEDSTARTDATE TYPE STRING,
PLANNEDSTARTTIME TYPE STRING,
PLANNEDENDDATE TYPE STRING,
PLANNEDENDTIME TYPE STRING,
SCHEDULEDBASICSTARTDATE TYPE STRING,
SCHEDULEDBASICSTARTTIME TYPE STRING,
SCHEDULEDBASICENDDATE TYPE STRING,
SCHEDULEDBASICENDTIME TYPE STRING,
ACTUALSTARTDATE TYPE STRING,
ACTUALSTARTTIME TYPE STRING,
CONFIRMEDENDDATE TYPE STRING,
CONFIRMEDENDTIME TYPE STRING,
MAINTORDERREFERENCEDATE TYPE STRING,
CREATIONDATETIME TYPE STRING,
LASTCHANGEDATETIME TYPE STRING,
SCHEDULEDBASICENDDATETIME TYPE STRING,
CONFIRMEDENDDATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
TECHNICALOBJECT TYPE STRING,
TECHNICALOBJECTTYPE TYPE STRING,
TECHOBJISEQUIPORFUNCNLLOC TYPE STRING,
ORDERLEADTIMEDURATION TYPE STRING,
ORDERRUNTIMEDURATION TYPE STRING,
ORDERDURATIONUNIT TYPE STRING,
NUMBEROFCREATEDMAINTORDERS TYPE STRING,
NUMBEROFORDERS TYPE STRING,
NUMBEROFCOMPLETEDMAINTORDERS TYPE STRING,
NUMBEROFPLANNEDMAINTORDERS TYPE STRING,
NUMBEROFUNPLANNEDMAINTORDERS TYPE STRING,
NUMBEROFIMMEDIATEMAINTORDERS TYPE STRING,
NMBROFMAINTORDSNOTTOBEEXECUTED TYPE STRING,
NMBROFOUTSTANDINGMAINTORDERS TYPE STRING,
NMBROFMAINTORDSCOMPLETEDONTIME TYPE STRING,
NMBROFHISTORICALORDERS TYPE STRING,
MAINWORKCENTERINTERNALID TYPE STRING,
WORKCENTERINTERNALID TYPE STRING,
WORKCENTERTYPECODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_IMNTORDTOCUBE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IMNTORDTOCUBE_STR-MANDT sy-vline
WA_IMNTORDTOCUBE_STR-MAINTENANCEORDER sy-vline
WA_IMNTORDTOCUBE_STR-MAINTENANCEORDERISHISTORICAL sy-vline
WA_IMNTORDTOCUBE_STR-MAINTENANCEORDERTYPE sy-vline
WA_IMNTORDTOCUBE_STR-MAINTENANCEORDERDESC sy-vline
WA_IMNTORDTOCUBE_STR-MAINTPRIORITY sy-vline
WA_IMNTORDTOCUBE_STR-MAINTPRIORITYTYPE sy-vline
WA_IMNTORDTOCUBE_STR-FUNCTIONALLOCATION sy-vline
WA_IMNTORDTOCUBE_STR-EQUIPMENT sy-vline
WA_IMNTORDTOCUBE_STR-ASSEMBLY sy-vline
WA_IMNTORDTOCUBE_STR-MATERIAL sy-vline
WA_IMNTORDTOCUBE_STR-SERIALNUMBER sy-vline
WA_IMNTORDTOCUBE_STR-MAINTENANCENOTIFICATION sy-vline
WA_IMNTORDTOCUBE_STR-LEADINGORDER sy-vline
WA_IMNTORDTOCUBE_STR-MAINTENANCEPLANNERGROUP sy-vline
WA_IMNTORDTOCUBE_STR-MAINTENANCEPLANNINGPLANT sy-vline
WA_IMNTORDTOCUBE_STR-MAINTORDPERSONRESPONSIBLE sy-vline
WA_IMNTORDTOCUBE_STR-MAINTENANCEREVISION sy-vline
WA_IMNTORDTOCUBE_STR-MAINTENANCEPLAN sy-vline
WA_IMNTORDTOCUBE_STR-MAINTENANCEITEM sy-vline
WA_IMNTORDTOCUBE_STR-TASKLISTTYPE sy-vline
WA_IMNTORDTOCUBE_STR-TASKLISTGROUP sy-vline
WA_IMNTORDTOCUBE_STR-TASKLISTGROUPCOUNTER sy-vline
WA_IMNTORDTOCUBE_STR-MAINTENANCEORDERPLANNINGCODE sy-vline
WA_IMNTORDTOCUBE_STR-MAINTENANCEACTIVITYTYPE sy-vline
WA_IMNTORDTOCUBE_STR-ABCINDICATOR sy-vline
WA_IMNTORDTOCUBE_STR-MAINTENANCEPLANT sy-vline
WA_IMNTORDTOCUBE_STR-ASSETLOCATION sy-vline
WA_IMNTORDTOCUBE_STR-ASSETROOM sy-vline
WA_IMNTORDTOCUBE_STR-MAINTENANCEPROCESSINGPHASE sy-vline
WA_IMNTORDTOCUBE_STR-OPERATIONSYSTEMCONDITION sy-vline
WA_IMNTORDTOCUBE_STR-PLANTSECTION sy-vline
WA_IMNTORDTOCUBE_STR-MAINWORKCENTER sy-vline
WA_IMNTORDTOCUBE_STR-MAINWORKCENTERPLANT sy-vline
WA_IMNTORDTOCUBE_STR-WORKCENTER sy-vline
WA_IMNTORDTOCUBE_STR-WORKCENTERPLANT sy-vline
WA_IMNTORDTOCUBE_STR-REFERENCEELEMENT sy-vline
WA_IMNTORDTOCUBE_STR-COSTCENTER sy-vline
WA_IMNTORDTOCUBE_STR-CONTROLLINGAREA sy-vline
WA_IMNTORDTOCUBE_STR-SUPERIORPROJECTNETWORK sy-vline
WA_IMNTORDTOCUBE_STR-COMPANYCODE sy-vline
WA_IMNTORDTOCUBE_STR-BUSINESSAREA sy-vline
WA_IMNTORDTOCUBE_STR-WBSELEMENTINTERNALID sy-vline
WA_IMNTORDTOCUBE_STR-MASTERFIXEDASSET sy-vline
WA_IMNTORDTOCUBE_STR-FIXEDASSET sy-vline
WA_IMNTORDTOCUBE_STR-SETTLEMENTORDER sy-vline
WA_IMNTORDTOCUBE_STR-MAINTENANCEORDERINTERNALID sy-vline
WA_IMNTORDTOCUBE_STR-ISMARKEDFORDELETION sy-vline
WA_IMNTORDTOCUBE_STR-CREATIONDATE sy-vline
WA_IMNTORDTOCUBE_STR-CREATIONTIME sy-vline
WA_IMNTORDTOCUBE_STR-LASTCHANGEDATE sy-vline
WA_IMNTORDTOCUBE_STR-LASTCHANGETIME sy-vline
WA_IMNTORDTOCUBE_STR-PLANNEDSTARTDATE sy-vline
WA_IMNTORDTOCUBE_STR-PLANNEDSTARTTIME sy-vline
WA_IMNTORDTOCUBE_STR-PLANNEDENDDATE sy-vline
WA_IMNTORDTOCUBE_STR-PLANNEDENDTIME sy-vline
WA_IMNTORDTOCUBE_STR-SCHEDULEDBASICSTARTDATE sy-vline
WA_IMNTORDTOCUBE_STR-SCHEDULEDBASICSTARTTIME sy-vline
WA_IMNTORDTOCUBE_STR-SCHEDULEDBASICENDDATE sy-vline
WA_IMNTORDTOCUBE_STR-SCHEDULEDBASICENDTIME sy-vline
WA_IMNTORDTOCUBE_STR-ACTUALSTARTDATE sy-vline
WA_IMNTORDTOCUBE_STR-ACTUALSTARTTIME sy-vline
WA_IMNTORDTOCUBE_STR-CONFIRMEDENDDATE sy-vline
WA_IMNTORDTOCUBE_STR-CONFIRMEDENDTIME sy-vline
WA_IMNTORDTOCUBE_STR-MAINTORDERREFERENCEDATE sy-vline
WA_IMNTORDTOCUBE_STR-CREATIONDATETIME sy-vline
WA_IMNTORDTOCUBE_STR-LASTCHANGEDATETIME sy-vline
WA_IMNTORDTOCUBE_STR-SCHEDULEDBASICENDDATETIME sy-vline
WA_IMNTORDTOCUBE_STR-CONFIRMEDENDDATETIME sy-vline
WA_IMNTORDTOCUBE_STR-CREATEDBYUSER sy-vline
WA_IMNTORDTOCUBE_STR-LASTCHANGEDBYUSER sy-vline
WA_IMNTORDTOCUBE_STR-TECHNICALOBJECT sy-vline
WA_IMNTORDTOCUBE_STR-TECHNICALOBJECTTYPE sy-vline
WA_IMNTORDTOCUBE_STR-TECHOBJISEQUIPORFUNCNLLOC sy-vline
WA_IMNTORDTOCUBE_STR-ORDERLEADTIMEDURATION sy-vline
WA_IMNTORDTOCUBE_STR-ORDERRUNTIMEDURATION sy-vline
WA_IMNTORDTOCUBE_STR-ORDERDURATIONUNIT sy-vline
WA_IMNTORDTOCUBE_STR-NUMBEROFCREATEDMAINTORDERS sy-vline
WA_IMNTORDTOCUBE_STR-NUMBEROFORDERS sy-vline
WA_IMNTORDTOCUBE_STR-NUMBEROFCOMPLETEDMAINTORDERS sy-vline
WA_IMNTORDTOCUBE_STR-NUMBEROFPLANNEDMAINTORDERS sy-vline
WA_IMNTORDTOCUBE_STR-NUMBEROFUNPLANNEDMAINTORDERS sy-vline
WA_IMNTORDTOCUBE_STR-NUMBEROFIMMEDIATEMAINTORDERS sy-vline
WA_IMNTORDTOCUBE_STR-NMBROFMAINTORDSNOTTOBEEXECUTED sy-vline
WA_IMNTORDTOCUBE_STR-NMBROFOUTSTANDINGMAINTORDERS sy-vline
WA_IMNTORDTOCUBE_STR-NMBROFMAINTORDSCOMPLETEDONTIME sy-vline
WA_IMNTORDTOCUBE_STR-NMBROFHISTORICALORDERS sy-vline
WA_IMNTORDTOCUBE_STR-MAINWORKCENTERINTERNALID sy-vline
WA_IMNTORDTOCUBE_STR-WORKCENTERINTERNALID sy-vline
WA_IMNTORDTOCUBE_STR-WORKCENTERTYPECODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.