ABAP Select data from SAP table INM_TS_SMD_OBJECT_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP INM_TS_SMD_OBJECT_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to INM_TS_SMD_OBJECT_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the INM_TS_SMD_OBJECT_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_INM_TS_SMD_OBJECT_DATA TYPE STANDARD TABLE OF INM_TS_SMD_OBJECT_DATA,
      WA_INM_TS_SMD_OBJECT_DATA TYPE INM_TS_SMD_OBJECT_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <INM_TS_SMD_OBJECT_DATA> TYPE INM_TS_SMD_OBJECT_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_INM_TS_SMD_OBJECT_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM INM_TS_SMD_OBJECT_DATA
  INTO TABLE IT_INM_TS_SMD_OBJECT_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM INM_TS_SMD_OBJECT_DATA
*  INTO TABLE @DATA(IT_INM_TS_SMD_OBJECT_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_INM_TS_SMD_OBJECT_DATA INDEX 1 INTO DATA(WA_INM_TS_SMD_OBJECT_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_INM_TS_SMD_OBJECT_DATA ASSIGNING <INM_TS_SMD_OBJECT_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<INM_TS_SMD_OBJECT_DATA>-BASE_TYPE_ID = 1.
<INM_TS_SMD_OBJECT_DATA>-CHANGE_TOKEN = 1.
<INM_TS_SMD_OBJECT_DATA>-CHECKIN_COMMENT = 1.
<INM_TS_SMD_OBJECT_DATA>-CONTENT_STREAM_FILE_NAME = 1.
<INM_TS_SMD_OBJECT_DATA>-CONTENT_STREAM_ID = 1.
ENDLOOP.

LOOP AT IT_INM_TS_SMD_OBJECT_DATA INTO WA_INM_TS_SMD_OBJECT_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_INM_TS_SMD_OBJECT_DATA-CONTENT_STREAM_LENGTH, sy-vline,
WA_INM_TS_SMD_OBJECT_DATA-CONTENT_STREAM_MIME_TYPE, sy-vline,
WA_INM_TS_SMD_OBJECT_DATA-CREATED_BY, sy-vline,
WA_INM_TS_SMD_OBJECT_DATA-CREATION_DATE, sy-vline,
WA_INM_TS_SMD_OBJECT_DATA-DESCRIPTION, sy-vline,
WA_INM_TS_SMD_OBJECT_DATA-DOC_DESCRIPTION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_INM_TS_SMD_OBJECT_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_INM_TS_SMD_OBJECT_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_INM_TS_SMD_OBJECT_DATA INTO WA_INM_TS_SMD_OBJECT_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_INM_TS_SMD_OBJECT_DATA_STR,
BASE_TYPE_ID TYPE STRING,
CHANGE_TOKEN TYPE STRING,
CHECKIN_COMMENT TYPE STRING,
CONTENT_STREAM_FILE_NAME TYPE STRING,
CONTENT_STREAM_ID TYPE STRING,
CONTENT_STREAM_LENGTH TYPE STRING,
CONTENT_STREAM_MIME_TYPE TYPE STRING,
CREATED_BY TYPE STRING,
CREATION_DATE TYPE STRING,
DESCRIPTION TYPE STRING,
DOC_DESCRIPTION TYPE STRING,
IS_IMMUTABLE TYPE STRING,
IS_LATEST_MAJOR_VERSION TYPE STRING,
IS_LATEST_VERSION TYPE STRING,
IS_MAJOR_VERSION TYPE STRING,
IS_PRIVATE_WORKING_COPY TYPE STRING,
IS_VERSION_SERIES_CHECKED_OUT TYPE STRING,
LAST_MODIFICATION_DATE TYPE STRING,
LAST_MODIFIED_BY TYPE STRING,
NAME TYPE STRING,
OBJECT_ID TYPE STRING,
OBJECT_TYPE_ID TYPE STRING,
SECONDARY_OBJECT_TYPE_IDS TYPE STRING,
VERSION_LABEL TYPE STRING,
VERSION_SERIES_CHECKED_OUT_BY TYPE STRING,
VERSION_SERIES_CHECKED_OUT_ID TYPE STRING,
VERSION_SERIES_ID TYPE STRING,
STATUS TYPE STRING,
ALLOWED_CHILD_OBJECT_TYPE_IDS TYPE STRING,
PARENT_ID TYPE STRING,
PATH TYPE STRING,
CHECKED_OUT TYPE STRING,
CHECKOUT_USER TYPE STRING,
DOCUMENT_GUID TYPE STRING,
IS_DELETABLE TYPE STRING,
DOCUMENT_NAME TYPE STRING,
CAN_CREATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_INM_TS_SMD_OBJECT_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-BASE_TYPE_ID sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-CHANGE_TOKEN sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-CHECKIN_COMMENT sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-CONTENT_STREAM_FILE_NAME sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-CONTENT_STREAM_ID sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-CONTENT_STREAM_LENGTH sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-CONTENT_STREAM_MIME_TYPE sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-CREATED_BY sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-CREATION_DATE sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-DESCRIPTION sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-DOC_DESCRIPTION sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-IS_IMMUTABLE sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-IS_LATEST_MAJOR_VERSION sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-IS_LATEST_VERSION sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-IS_MAJOR_VERSION sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-IS_PRIVATE_WORKING_COPY sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-IS_VERSION_SERIES_CHECKED_OUT sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-LAST_MODIFICATION_DATE sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-LAST_MODIFIED_BY sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-NAME sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-OBJECT_ID sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-OBJECT_TYPE_ID sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-SECONDARY_OBJECT_TYPE_IDS sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-VERSION_LABEL sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-VERSION_SERIES_CHECKED_OUT_BY sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-VERSION_SERIES_CHECKED_OUT_ID sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-VERSION_SERIES_ID sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-STATUS sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-ALLOWED_CHILD_OBJECT_TYPE_IDS sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-PARENT_ID sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-PATH sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-CHECKED_OUT sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-CHECKOUT_USER sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-DOCUMENT_GUID sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-IS_DELETABLE sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-DOCUMENT_NAME sy-vline
WA_INM_TS_SMD_OBJECT_DATA_STR-CAN_CREATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.