ABAP Select data from SAP table IOMATVER into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP IOMATVER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IOMATVER. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the IOMATVER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_IOMATVER TYPE STANDARD TABLE OF IOMATVER, WA_IOMATVER TYPE IOMATVER, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <IOMATVER> TYPE IOMATVER. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_IOMATVER. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM IOMATVER INTO TABLE IT_IOMATVER. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM IOMATVER * INTO TABLE @DATA(IT_IOMATVER2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_IOMATVER INDEX 1 INTO DATA(WA_IOMATVER2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_IOMATVER ASSIGNING <IOMATVER>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<IOMATVER>-OBJNR = 1.
<IOMATVER>-MATERIAL_TEXT = 1.
<IOMATVER>-ORDER_TYPE = 1.
<IOMATVER>-ORDER_CATEGORY = 1.
<IOMATVER>-CONF_REASON_TEXT = 1.
ENDLOOP. LOOP AT IT_IOMATVER INTO WA_IOMATVER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_IOMATVER-PROBCLASS, sy-vline,
WA_IOMATVER-ICON_MSGTY, sy-vline,
WA_IOMATVER-AUFNR, sy-vline,
WA_IOMATVER-MATNR, sy-vline,
WA_IOMATVER-PRODVER, sy-vline,
WA_IOMATVER-WERKS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IOMATVER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IOMATVER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IOMATVER INTO WA_IOMATVER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IOMATVER-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IOMATVER-AUFNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IOMATVER-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IOMATVER-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field REVLEVEL CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_IOMATVER-REVLEVEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IOMATVER-REVLEVEL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field CONF_REM_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_IOMATVER-CONF_REM_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IOMATVER-CONF_REM_UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field CONF_REM_REPPOINT CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_IOMATVER-CONF_REM_REPPOINT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IOMATVER-CONF_REM_REPPOINT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IOMATVER_STR,
OBJNR TYPE STRING,
MATERIAL_TEXT TYPE STRING,
ORDER_TYPE TYPE STRING,
ORDER_CATEGORY TYPE STRING,
CONF_REASON_TEXT TYPE STRING,
PROBCLASS TYPE STRING,
ICON_MSGTY TYPE STRING,
AUFNR TYPE STRING,
MATNR TYPE STRING,
PRODVER TYPE STRING,
WERKS TYPE STRING,
PLANNING_PLANT TYPE STRING,
STORLOC TYPE STRING,
REVLEVEL TYPE STRING,
PRODLINE TYPE STRING,
PLANNINGID TYPE STRING,
CONF_REM_QUANTITY TYPE STRING,
CONF_REM_SCRAP TYPE STRING,
CONF_REM_UNIT TYPE STRING,
CONF_REM_REPPOINT TYPE STRING,
CONF_REM_BATCH TYPE STRING,
CONF_REM_REASON TYPE STRING,
CONF_REM_SCRAP_TYPE TYPE STRING,
CONF_REM_POSTING_DATE TYPE STRING,
CONF_REM_DOCUMENT_DATE TYPE STRING,
CONF_REM_HEADER_TEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_IOMATVER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IOMATVER_STR-OBJNR sy-vline
WA_IOMATVER_STR-MATERIAL_TEXT sy-vline
WA_IOMATVER_STR-ORDER_TYPE sy-vline
WA_IOMATVER_STR-ORDER_CATEGORY sy-vline
WA_IOMATVER_STR-CONF_REASON_TEXT sy-vline
WA_IOMATVER_STR-PROBCLASS sy-vline
WA_IOMATVER_STR-ICON_MSGTY sy-vline
WA_IOMATVER_STR-AUFNR sy-vline
WA_IOMATVER_STR-MATNR sy-vline
WA_IOMATVER_STR-PRODVER sy-vline
WA_IOMATVER_STR-WERKS sy-vline
WA_IOMATVER_STR-PLANNING_PLANT sy-vline
WA_IOMATVER_STR-STORLOC sy-vline
WA_IOMATVER_STR-REVLEVEL sy-vline
WA_IOMATVER_STR-PRODLINE sy-vline
WA_IOMATVER_STR-PLANNINGID sy-vline
WA_IOMATVER_STR-CONF_REM_QUANTITY sy-vline
WA_IOMATVER_STR-CONF_REM_SCRAP sy-vline
WA_IOMATVER_STR-CONF_REM_UNIT sy-vline
WA_IOMATVER_STR-CONF_REM_REPPOINT sy-vline
WA_IOMATVER_STR-CONF_REM_BATCH sy-vline
WA_IOMATVER_STR-CONF_REM_REASON sy-vline
WA_IOMATVER_STR-CONF_REM_SCRAP_TYPE sy-vline
WA_IOMATVER_STR-CONF_REM_POSTING_DATE sy-vline
WA_IOMATVER_STR-CONF_REM_DOCUMENT_DATE sy-vline
WA_IOMATVER_STR-CONF_REM_HEADER_TEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.