ABAP Select data from SAP table IQLTYNOTIFKFCUBE into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP IQLTYNOTIFKFCUBE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IQLTYNOTIFKFCUBE. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the IQLTYNOTIFKFCUBE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_IQLTYNOTIFKFCUBE TYPE STANDARD TABLE OF IQLTYNOTIFKFCUBE, WA_IQLTYNOTIFKFCUBE TYPE IQLTYNOTIFKFCUBE, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <IQLTYNOTIFKFCUBE> TYPE IQLTYNOTIFKFCUBE. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_IQLTYNOTIFKFCUBE. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM IQLTYNOTIFKFCUBE INTO TABLE IT_IQLTYNOTIFKFCUBE. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM IQLTYNOTIFKFCUBE * INTO TABLE @DATA(IT_IQLTYNOTIFKFCUBE2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_IQLTYNOTIFKFCUBE INDEX 1 INTO DATA(WA_IQLTYNOTIFKFCUBE2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_IQLTYNOTIFKFCUBE ASSIGNING <IQLTYNOTIFKFCUBE>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<IQLTYNOTIFKFCUBE>-MANDT = 1.
<IQLTYNOTIFKFCUBE>-QUALITYNOTIFICATION = 1.
<IQLTYNOTIFKFCUBE>-NOTIFICATIONTYPE = 1.
<IQLTYNOTIFKFCUBE>-ISBUSINESSPURPOSECOMPLETED = 1.
<IQLTYNOTIFKFCUBE>-ISDELETED = 1.
ENDLOOP. LOOP AT IT_IQLTYNOTIFKFCUBE INTO WA_IQLTYNOTIFKFCUBE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_IQLTYNOTIFKFCUBE-CREATIONDATE, sy-vline,
WA_IQLTYNOTIFKFCUBE-MAINWORKCENTERINTERNALID, sy-vline,
WA_IQLTYNOTIFKFCUBE-MAINWORKCENTERPLANT, sy-vline,
WA_IQLTYNOTIFKFCUBE-WORKCENTERTYPECODE, sy-vline,
WA_IQLTYNOTIFKFCUBE-WORKCENTER, sy-vline,
WA_IQLTYNOTIFKFCUBE-WORKCENTERTEXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IQLTYNOTIFKFCUBE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IQLTYNOTIFKFCUBE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IQLTYNOTIFKFCUBE INTO WA_IQLTYNOTIFKFCUBE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field QUALITYNOTIFICATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IQLTYNOTIFKFCUBE-QUALITYNOTIFICATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IQLTYNOTIFKFCUBE-QUALITYNOTIFICATION.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SUPPLIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IQLTYNOTIFKFCUBE-SUPPLIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IQLTYNOTIFKFCUBE-SUPPLIER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field CUSTOMER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IQLTYNOTIFKFCUBE-CUSTOMER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IQLTYNOTIFKFCUBE-CUSTOMER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_IQLTYNOTIFKFCUBE-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IQLTYNOTIFKFCUBE-MATERIAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IQLTYNOTIFKFCUBE_STR,
MANDT TYPE STRING,
QUALITYNOTIFICATION TYPE STRING,
NOTIFICATIONTYPE TYPE STRING,
ISBUSINESSPURPOSECOMPLETED TYPE STRING,
ISDELETED TYPE STRING,
CREATIONDATE TYPE STRING,
MAINWORKCENTERINTERNALID TYPE STRING,
MAINWORKCENTERPLANT TYPE STRING,
WORKCENTERTYPECODE TYPE STRING,
WORKCENTER TYPE STRING,
WORKCENTERTEXT TYPE STRING,
SUPPLIER TYPE STRING,
CUSTOMER TYPE STRING,
MATERIAL TYPE STRING,
PLANT TYPE STRING,
WORKCENTERPLANT TYPE STRING,
NOTIFICATIONCOMPLETIONDATE TYPE STRING,
NOTIFICATIONREQUIREDSTARTDATE TYPE STRING,
NOTIFICATIONREQUIREDENDDATE TYPE STRING,
QUALITYNOTIFICATIONCOUNT TYPE STRING,
QLTYNOTIFPROCESSPERIOD TYPE STRING,
CNTOFQLTYNOTIFOVERDUE TYPE STRING,END OF T_EKKO_STR. DATA: WA_IQLTYNOTIFKFCUBE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IQLTYNOTIFKFCUBE_STR-MANDT sy-vline
WA_IQLTYNOTIFKFCUBE_STR-QUALITYNOTIFICATION sy-vline
WA_IQLTYNOTIFKFCUBE_STR-NOTIFICATIONTYPE sy-vline
WA_IQLTYNOTIFKFCUBE_STR-ISBUSINESSPURPOSECOMPLETED sy-vline
WA_IQLTYNOTIFKFCUBE_STR-ISDELETED sy-vline
WA_IQLTYNOTIFKFCUBE_STR-CREATIONDATE sy-vline
WA_IQLTYNOTIFKFCUBE_STR-MAINWORKCENTERINTERNALID sy-vline
WA_IQLTYNOTIFKFCUBE_STR-MAINWORKCENTERPLANT sy-vline
WA_IQLTYNOTIFKFCUBE_STR-WORKCENTERTYPECODE sy-vline
WA_IQLTYNOTIFKFCUBE_STR-WORKCENTER sy-vline
WA_IQLTYNOTIFKFCUBE_STR-WORKCENTERTEXT sy-vline
WA_IQLTYNOTIFKFCUBE_STR-SUPPLIER sy-vline
WA_IQLTYNOTIFKFCUBE_STR-CUSTOMER sy-vline
WA_IQLTYNOTIFKFCUBE_STR-MATERIAL sy-vline
WA_IQLTYNOTIFKFCUBE_STR-PLANT sy-vline
WA_IQLTYNOTIFKFCUBE_STR-WORKCENTERPLANT sy-vline
WA_IQLTYNOTIFKFCUBE_STR-NOTIFICATIONCOMPLETIONDATE sy-vline
WA_IQLTYNOTIFKFCUBE_STR-NOTIFICATIONREQUIREDSTARTDATE sy-vline
WA_IQLTYNOTIFKFCUBE_STR-NOTIFICATIONREQUIREDENDDATE sy-vline
WA_IQLTYNOTIFKFCUBE_STR-QUALITYNOTIFICATIONCOUNT sy-vline
WA_IQLTYNOTIFKFCUBE_STR-QLTYNOTIFPROCESSPERIOD sy-vline
WA_IQLTYNOTIFKFCUBE_STR-CNTOFQLTYNOTIFOVERDUE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.