ABAP Select data from SAP table IREINTOBJLVL2VH into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP IREINTOBJLVL2VH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IREINTOBJLVL2VH. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the IREINTOBJLVL2VH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_IREINTOBJLVL2VH TYPE STANDARD TABLE OF IREINTOBJLVL2VH, WA_IREINTOBJLVL2VH TYPE IREINTOBJLVL2VH, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <IREINTOBJLVL2VH> TYPE IREINTOBJLVL2VH. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_IREINTOBJLVL2VH. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM IREINTOBJLVL2VH INTO TABLE IT_IREINTOBJLVL2VH. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM IREINTOBJLVL2VH * INTO TABLE @DATA(IT_IREINTOBJLVL2VH2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_IREINTOBJLVL2VH INDEX 1 INTO DATA(WA_IREINTOBJLVL2VH2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_IREINTOBJLVL2VH ASSIGNING <IREINTOBJLVL2VH>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<IREINTOBJLVL2VH>-MANDT = 1.
<IREINTOBJLVL2VH>-REINTEGRATIONOBJECTNUMBERLVL2 = 1.
<IREINTOBJLVL2VH>-INTERNALREALESTATENUMBERLVL2 = 1.
<IREINTOBJLVL2VH>-REIDENTIFICATION = 1.
<IREINTOBJLVL2VH>-REALESTATEEXTERNALIDLVL0 = 1.
ENDLOOP. LOOP AT IT_IREINTOBJLVL2VH INTO WA_IREINTOBJLVL2VH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_IREINTOBJLVL2VH-INTERNALREALESTATENUMBERLVL0, sy-vline,
WA_IREINTOBJLVL2VH-REINTEGOBJECTSITENAME, sy-vline,
WA_IREINTOBJLVL2VH-REALESTATEEXTERNALIDLVL1, sy-vline,
WA_IREINTOBJLVL2VH-INTERNALREALESTATENUMBERLVL1, sy-vline,
WA_IREINTOBJLVL2VH-REINTEGOBJECTBUILDINGNAME, sy-vline,
WA_IREINTOBJLVL2VH-REINTEGOBJECTLANDNAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IREINTOBJLVL2VH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IREINTOBJLVL2VH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IREINTOBJLVL2VH INTO WA_IREINTOBJLVL2VH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field REINTEGRATIONOBJECTNUMBERLVL2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IREINTOBJLVL2VH-REINTEGRATIONOBJECTNUMBERLVL2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IREINTOBJLVL2VH-REINTEGRATIONOBJECTNUMBERLVL2.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IREINTOBJLVL2VH_STR,
MANDT TYPE STRING,
REINTEGRATIONOBJECTNUMBERLVL2 TYPE STRING,
INTERNALREALESTATENUMBERLVL2 TYPE STRING,
REIDENTIFICATION TYPE STRING,
REALESTATEEXTERNALIDLVL0 TYPE STRING,
INTERNALREALESTATENUMBERLVL0 TYPE STRING,
REINTEGOBJECTSITENAME TYPE STRING,
REALESTATEEXTERNALIDLVL1 TYPE STRING,
INTERNALREALESTATENUMBERLVL1 TYPE STRING,
REINTEGOBJECTBUILDINGNAME TYPE STRING,
REINTEGOBJECTLANDNAME TYPE STRING,
VALIDITYSTARTDATELVL1 TYPE STRING,
VALIDITYENDDATELVL1 TYPE STRING,
REINTEGRATIONOBJECTNAME TYPE STRING,
VALIDITYSTARTDATE TYPE STRING,
VALIDITYENDDATE TYPE STRING,
RESTATUSOBJECT TYPE STRING,
RESPACEGROUPUSAGETYPE TYPE STRING,
RESPACEGRPENABLEUSETYPE TYPE STRING,
REINTEGOBJSPACEGROUPTYPE TYPE STRING,
REINTEGOBJECTLONGNAME TYPE STRING,
RESPONSIBLE TYPE STRING,
REAUTHORIZATIONGROUP TYPE STRING,
REINTEGOBJECTREFERENCE TYPE STRING,END OF T_EKKO_STR. DATA: WA_IREINTOBJLVL2VH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IREINTOBJLVL2VH_STR-MANDT sy-vline
WA_IREINTOBJLVL2VH_STR-REINTEGRATIONOBJECTNUMBERLVL2 sy-vline
WA_IREINTOBJLVL2VH_STR-INTERNALREALESTATENUMBERLVL2 sy-vline
WA_IREINTOBJLVL2VH_STR-REIDENTIFICATION sy-vline
WA_IREINTOBJLVL2VH_STR-REALESTATEEXTERNALIDLVL0 sy-vline
WA_IREINTOBJLVL2VH_STR-INTERNALREALESTATENUMBERLVL0 sy-vline
WA_IREINTOBJLVL2VH_STR-REINTEGOBJECTSITENAME sy-vline
WA_IREINTOBJLVL2VH_STR-REALESTATEEXTERNALIDLVL1 sy-vline
WA_IREINTOBJLVL2VH_STR-INTERNALREALESTATENUMBERLVL1 sy-vline
WA_IREINTOBJLVL2VH_STR-REINTEGOBJECTBUILDINGNAME sy-vline
WA_IREINTOBJLVL2VH_STR-REINTEGOBJECTLANDNAME sy-vline
WA_IREINTOBJLVL2VH_STR-VALIDITYSTARTDATELVL1 sy-vline
WA_IREINTOBJLVL2VH_STR-VALIDITYENDDATELVL1 sy-vline
WA_IREINTOBJLVL2VH_STR-REINTEGRATIONOBJECTNAME sy-vline
WA_IREINTOBJLVL2VH_STR-VALIDITYSTARTDATE sy-vline
WA_IREINTOBJLVL2VH_STR-VALIDITYENDDATE sy-vline
WA_IREINTOBJLVL2VH_STR-RESTATUSOBJECT sy-vline
WA_IREINTOBJLVL2VH_STR-RESPACEGROUPUSAGETYPE sy-vline
WA_IREINTOBJLVL2VH_STR-RESPACEGRPENABLEUSETYPE sy-vline
WA_IREINTOBJLVL2VH_STR-REINTEGOBJSPACEGROUPTYPE sy-vline
WA_IREINTOBJLVL2VH_STR-REINTEGOBJECTLONGNAME sy-vline
WA_IREINTOBJLVL2VH_STR-RESPONSIBLE sy-vline
WA_IREINTOBJLVL2VH_STR-REAUTHORIZATIONGROUP sy-vline
WA_IREINTOBJLVL2VH_STR-REINTEGOBJECTREFERENCE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.