ABAP Select data from SAP table IRERENTOBJECTVH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IRERENTOBJECTVH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IRERENTOBJECTVH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IRERENTOBJECTVH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IRERENTOBJECTVH TYPE STANDARD TABLE OF IRERENTOBJECTVH,
      WA_IRERENTOBJECTVH TYPE IRERENTOBJECTVH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IRERENTOBJECTVH> TYPE IRERENTOBJECTVH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IRERENTOBJECTVH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IRERENTOBJECTVH
  INTO TABLE IT_IRERENTOBJECTVH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IRERENTOBJECTVH
*  INTO TABLE @DATA(IT_IRERENTOBJECTVH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IRERENTOBJECTVH INDEX 1 INTO DATA(WA_IRERENTOBJECTVH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IRERENTOBJECTVH ASSIGNING <IRERENTOBJECTVH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IRERENTOBJECTVH>-MANDT = 1.
<IRERENTOBJECTVH>-INTERNALREALESTATENUMBER = 1.
<IRERENTOBJECTVH>-COMPANYCODE = 1.
<IRERENTOBJECTVH>-REBUSINESSENTITY = 1.
<IRERENTOBJECTVH>-RERENTALOBJECT = 1.
ENDLOOP.

LOOP AT IT_IRERENTOBJECTVH INTO WA_IRERENTOBJECTVH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IRERENTOBJECTVH-RENTALOBJECTTYPE, sy-vline,
WA_IRERENTOBJECTVH-RERENTALOBJECTUSAGETYPE, sy-vline,
WA_IRERENTOBJECTVH-REALESTATEBUILDING, sy-vline,
WA_IRERENTOBJECTVH-REALESTATEPROPERTY, sy-vline,
WA_IRERENTOBJECTVH-REINITIALUSAGEDATE, sy-vline,
WA_IRERENTOBJECTVH-RELOCATIONONFLOOR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IRERENTOBJECTVH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IRERENTOBJECTVH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IRERENTOBJECTVH INTO WA_IRERENTOBJECTVH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RELOCATIONONFLOOR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_IRERENTOBJECTVH-RELOCATIONONFLOOR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_IRERENTOBJECTVH-RELOCATIONONFLOOR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IRERENTOBJECTVH_STR,
MANDT TYPE STRING,
INTERNALREALESTATENUMBER TYPE STRING,
COMPANYCODE TYPE STRING,
REBUSINESSENTITY TYPE STRING,
RERENTALOBJECT TYPE STRING,
RENTALOBJECTTYPE TYPE STRING,
RERENTALOBJECTUSAGETYPE TYPE STRING,
REALESTATEBUILDING TYPE STRING,
REALESTATEPROPERTY TYPE STRING,
REINITIALUSAGEDATE TYPE STRING,
RELOCATIONONFLOOR TYPE STRING,
RERENTALUNITNUMBERTEXT TYPE STRING,
RERENTALOBJECTNAME TYPE STRING,
RESTATUSOBJECT TYPE STRING,
REINTERNALFINNUMBER TYPE STRING,
RESPONSIBLE TYPE STRING,
REAUTHORIZATIONGROUP TYPE STRING,
REALESTATEOBJECTTYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_IRERENTOBJECTVH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IRERENTOBJECTVH_STR-MANDT sy-vline
WA_IRERENTOBJECTVH_STR-INTERNALREALESTATENUMBER sy-vline
WA_IRERENTOBJECTVH_STR-COMPANYCODE sy-vline
WA_IRERENTOBJECTVH_STR-REBUSINESSENTITY sy-vline
WA_IRERENTOBJECTVH_STR-RERENTALOBJECT sy-vline
WA_IRERENTOBJECTVH_STR-RENTALOBJECTTYPE sy-vline
WA_IRERENTOBJECTVH_STR-RERENTALOBJECTUSAGETYPE sy-vline
WA_IRERENTOBJECTVH_STR-REALESTATEBUILDING sy-vline
WA_IRERENTOBJECTVH_STR-REALESTATEPROPERTY sy-vline
WA_IRERENTOBJECTVH_STR-REINITIALUSAGEDATE sy-vline
WA_IRERENTOBJECTVH_STR-RELOCATIONONFLOOR sy-vline
WA_IRERENTOBJECTVH_STR-RERENTALUNITNUMBERTEXT sy-vline
WA_IRERENTOBJECTVH_STR-RERENTALOBJECTNAME sy-vline
WA_IRERENTOBJECTVH_STR-RESTATUSOBJECT sy-vline
WA_IRERENTOBJECTVH_STR-REINTERNALFINNUMBER sy-vline
WA_IRERENTOBJECTVH_STR-RESPONSIBLE sy-vline
WA_IRERENTOBJECTVH_STR-REAUTHORIZATIONGROUP sy-vline
WA_IRERENTOBJECTVH_STR-REALESTATEOBJECTTYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.