ABAP Select data from SAP table ISBUS_RULE_MAIN1 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISBUS_RULE_MAIN1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISBUS_RULE_MAIN1. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ISBUS_RULE_MAIN1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ISBUS_RULE_MAIN1 TYPE STANDARD TABLE OF ISBUS_RULE_MAIN1, WA_ISBUS_RULE_MAIN1 TYPE ISBUS_RULE_MAIN1, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ISBUS_RULE_MAIN1> TYPE ISBUS_RULE_MAIN1. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ISBUS_RULE_MAIN1. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ISBUS_RULE_MAIN1 INTO TABLE IT_ISBUS_RULE_MAIN1. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ISBUS_RULE_MAIN1 * INTO TABLE @DATA(IT_ISBUS_RULE_MAIN12). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ISBUS_RULE_MAIN1 INDEX 1 INTO DATA(WA_ISBUS_RULE_MAIN12). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ISBUS_RULE_MAIN1 ASSIGNING <ISBUS_RULE_MAIN1>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISBUS_RULE_MAIN1>-KEY = 1.
<ISBUS_RULE_MAIN1>-PARENT_KEY = 1.
<ISBUS_RULE_MAIN1>-ROOT_KEY = 1.
<ISBUS_RULE_MAIN1>-RULE_ID = 1.
<ISBUS_RULE_MAIN1>-RESIDENCE_PERIOD = 1.
ENDLOOP. LOOP AT IT_ISBUS_RULE_MAIN1 INTO WA_ISBUS_RULE_MAIN1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ISBUS_RULE_MAIN1-RESIDENCE_UNIT, sy-vline,
WA_ISBUS_RULE_MAIN1-RETENTION_PERIOD, sy-vline,
WA_ISBUS_RULE_MAIN1-RETENTION_UNIT, sy-vline,
WA_ISBUS_RULE_MAIN1-RULE_START_DATE, sy-vline,
WA_ISBUS_RULE_MAIN1-RULE_END_DATE, sy-vline,
WA_ISBUS_RULE_MAIN1-RULE_STATUS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISBUS_RULE_MAIN1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISBUS_RULE_MAIN1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISBUS_RULE_MAIN1 INTO WA_ISBUS_RULE_MAIN1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISBUS_RULE_MAIN1_STR,
KEY TYPE STRING,
PARENT_KEY TYPE STRING,
ROOT_KEY TYPE STRING,
RULE_ID TYPE STRING,
RESIDENCE_PERIOD TYPE STRING,
RESIDENCE_UNIT TYPE STRING,
RETENTION_PERIOD TYPE STRING,
RETENTION_UNIT TYPE STRING,
RULE_START_DATE TYPE STRING,
RULE_END_DATE TYPE STRING,
RULE_STATUS TYPE STRING,
AUTH_GROUP TYPE STRING,
RES_UNIT TYPE STRING,
START_DATE TYPE STRING,
END_DATE TYPE STRING,
STATUS TYPE STRING,
DATA_CONTROLLER TYPE STRING,
DESCRIPTION TYPE STRING,
AUTH_GRP TYPE STRING,
RET_UNIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISBUS_RULE_MAIN1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISBUS_RULE_MAIN1_STR-KEY sy-vline
WA_ISBUS_RULE_MAIN1_STR-PARENT_KEY sy-vline
WA_ISBUS_RULE_MAIN1_STR-ROOT_KEY sy-vline
WA_ISBUS_RULE_MAIN1_STR-RULE_ID sy-vline
WA_ISBUS_RULE_MAIN1_STR-RESIDENCE_PERIOD sy-vline
WA_ISBUS_RULE_MAIN1_STR-RESIDENCE_UNIT sy-vline
WA_ISBUS_RULE_MAIN1_STR-RETENTION_PERIOD sy-vline
WA_ISBUS_RULE_MAIN1_STR-RETENTION_UNIT sy-vline
WA_ISBUS_RULE_MAIN1_STR-RULE_START_DATE sy-vline
WA_ISBUS_RULE_MAIN1_STR-RULE_END_DATE sy-vline
WA_ISBUS_RULE_MAIN1_STR-RULE_STATUS sy-vline
WA_ISBUS_RULE_MAIN1_STR-AUTH_GROUP sy-vline
WA_ISBUS_RULE_MAIN1_STR-RES_UNIT sy-vline
WA_ISBUS_RULE_MAIN1_STR-START_DATE sy-vline
WA_ISBUS_RULE_MAIN1_STR-END_DATE sy-vline
WA_ISBUS_RULE_MAIN1_STR-STATUS sy-vline
WA_ISBUS_RULE_MAIN1_STR-DATA_CONTROLLER sy-vline
WA_ISBUS_RULE_MAIN1_STR-DESCRIPTION sy-vline
WA_ISBUS_RULE_MAIN1_STR-AUTH_GRP sy-vline
WA_ISBUS_RULE_MAIN1_STR-RET_UNIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.