ABAP Select data from SAP table ISOIL_ROIUVL_OILGAS_ILINE_PDF into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISOIL_ROIUVL_OILGAS_ILINE_PDF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISOIL_ROIUVL_OILGAS_ILINE_PDF. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ISOIL_ROIUVL_OILGAS_ILINE_PDF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ISOIL_ROIUVL_OILGAS_ILINE_PDF TYPE STANDARD TABLE OF ISOIL_ROIUVL_OILGAS_ILINE_PDF, WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF TYPE ISOIL_ROIUVL_OILGAS_ILINE_PDF, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ISOIL_ROIUVL_OILGAS_ILINE_PDF> TYPE ISOIL_ROIUVL_OILGAS_ILINE_PDF. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ISOIL_ROIUVL_OILGAS_ILINE_PDF. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ISOIL_ROIUVL_OILGAS_ILINE_PDF INTO TABLE IT_ISOIL_ROIUVL_OILGAS_ILINE_PDF. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ISOIL_ROIUVL_OILGAS_ILINE_PDF * INTO TABLE @DATA(IT_ISOIL_ROIUVL_OILGAS_ILINE_PDF2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ISOIL_ROIUVL_OILGAS_ILINE_PDF INDEX 1 INTO DATA(WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ISOIL_ROIUVL_OILGAS_ILINE_PDF ASSIGNING <ISOIL_ROIUVL_OILGAS_ILINE_PDF>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISOIL_ROIUVL_OILGAS_ILINE_PDF>-EFF_FROM_DT = 1.
<ISOIL_ROIUVL_OILGAS_ILINE_PDF>-EFF_TO_DT = 1.
<ISOIL_ROIUVL_OILGAS_ILINE_PDF>-ACTL_GR_VL = 1.
<ISOIL_ROIUVL_OILGAS_ILINE_PDF>-VOLUME_UNIT = 1.
<ISOIL_ROIUVL_OILGAS_ILINE_PDF>-VL_TYPE_CD = 1.
ENDLOOP. LOOP AT IT_ISOIL_ROIUVL_OILGAS_ILINE_PDF INTO WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-TRNSP_NO, sy-vline,
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-WI_OWN_ISQ_NO, sy-vline,
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-ACT_HEAT_VAL_FCT, sy-vline,
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-HEAT_VALUE_FCT_U, sy-vline,
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-PC_AMT, sy-vline,
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-PC_CURR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISOIL_ROIUVL_OILGAS_ILINE_PDF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISOIL_ROIUVL_OILGAS_ILINE_PDF INTO WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit CUNIT, internal->external for field VOLUME_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-VOLUME_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-VOLUME_UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field TRNSP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-TRNSP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-TRNSP_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field WI_OWN_ISQ_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-WI_OWN_ISQ_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-WI_OWN_ISQ_NO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field HEAT_VALUE_FCT_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-HEAT_VALUE_FCT_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-HEAT_VALUE_FCT_U.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field DENSITY_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-DENSITY_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF-DENSITY_U.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR,
EFF_FROM_DT TYPE STRING,
EFF_TO_DT TYPE STRING,
ACTL_GR_VL TYPE STRING,
VOLUME_UNIT TYPE STRING,
VL_TYPE_CD TYPE STRING,
TRNSP_NO TYPE STRING,
WI_OWN_ISQ_NO TYPE STRING,
ACT_HEAT_VAL_FCT TYPE STRING,
HEAT_VALUE_FCT_U TYPE STRING,
PC_AMT TYPE STRING,
PC_CURR TYPE STRING,
ACTL_GR_VAL_AM TYPE STRING,
VOLUME_AM TYPE STRING,
TRNSP_REF_NO TYPE STRING,
RUN_TKT_NO TYPE STRING,
DENSITY TYPE STRING,
GROSS_VAL_AM TYPE STRING,
DENSITY_U TYPE STRING,
MON TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-EFF_FROM_DT sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-EFF_TO_DT sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-ACTL_GR_VL sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-VOLUME_UNIT sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-VL_TYPE_CD sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-TRNSP_NO sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-WI_OWN_ISQ_NO sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-ACT_HEAT_VAL_FCT sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-HEAT_VALUE_FCT_U sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-PC_AMT sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-PC_CURR sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-ACTL_GR_VAL_AM sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-VOLUME_AM sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-TRNSP_REF_NO sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-RUN_TKT_NO sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-DENSITY sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-GROSS_VAL_AM sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-DENSITY_U sy-vline
WA_ISOIL_ROIUVL_OILGAS_ILINE_PDF_STR-MON sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.