ABAP Select data from SAP table ISTECHNICALOBJECTTP_DR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISTECHNICALOBJECTTP_DR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISTECHNICALOBJECTTP_DR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISTECHNICALOBJECTTP_DR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISTECHNICALOBJECTTP_DR TYPE STANDARD TABLE OF ISTECHNICALOBJECTTP_DR,
      WA_ISTECHNICALOBJECTTP_DR TYPE ISTECHNICALOBJECTTP_DR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISTECHNICALOBJECTTP_DR> TYPE ISTECHNICALOBJECTTP_DR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISTECHNICALOBJECTTP_DR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISTECHNICALOBJECTTP_DR
  INTO TABLE IT_ISTECHNICALOBJECTTP_DR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISTECHNICALOBJECTTP_DR
*  INTO TABLE @DATA(IT_ISTECHNICALOBJECTTP_DR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISTECHNICALOBJECTTP_DR INDEX 1 INTO DATA(WA_ISTECHNICALOBJECTTP_DR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISTECHNICALOBJECTTP_DR ASSIGNING <ISTECHNICALOBJECTTP_DR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISTECHNICALOBJECTTP_DR>-DRAFTUUID = 1.
<ISTECHNICALOBJECTTP_DR>-TECHNICALOBJECT = 1.
<ISTECHNICALOBJECTTP_DR>-TECHOBJISEQUIPORFUNCNLLOC = 1.
<ISTECHNICALOBJECTTP_DR>-TECHNICALOBJECTLABEL = 1.
<ISTECHNICALOBJECTTP_DR>-ISEQUIPORFUNCNLLOCFOREDIT = 1.
ENDLOOP.

LOOP AT IT_ISTECHNICALOBJECTTP_DR INTO WA_ISTECHNICALOBJECTTP_DR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISTECHNICALOBJECTTP_DR-TECHNICALOBJECTFOREDIT, sy-vline,
WA_ISTECHNICALOBJECTTP_DR-TECHNICALOBJECTCATEGORY, sy-vline,
WA_ISTECHNICALOBJECTTP_DR-EQUIPMENT, sy-vline,
WA_ISTECHNICALOBJECTTP_DR-FUNCTIONALLOCATION, sy-vline,
WA_ISTECHNICALOBJECTTP_DR-TECHNICALOBJECTTYPE, sy-vline,
WA_ISTECHNICALOBJECTTP_DR-CREATEDBYUSER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISTECHNICALOBJECTTP_DR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISTECHNICALOBJECTTP_DR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISTECHNICALOBJECTTP_DR INTO WA_ISTECHNICALOBJECTTP_DR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TECHO, internal->external for field TECHNICALOBJECTLABEL CALL FUNCTION 'CONVERSION_EXIT_TECHO_OUTPUT' EXPORTING input = WA_ISTECHNICALOBJECTTP_DR-TECHNICALOBJECTLABEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISTECHNICALOBJECTTP_DR-TECHNICALOBJECTLABEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISTECHNICALOBJECTTP_DR-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISTECHNICALOBJECTTP_DR-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field FUNCTIONALLOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_ISTECHNICALOBJECTTP_DR-FUNCTIONALLOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISTECHNICALOBJECTTP_DR-FUNCTIONALLOCATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field CONSTRUCTIONYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_ISTECHNICALOBJECTTP_DR-CONSTRUCTIONYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISTECHNICALOBJECTTP_DR-CONSTRUCTIONYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GROSSWEIGHTUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ISTECHNICALOBJECTTP_DR-GROSSWEIGHTUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISTECHNICALOBJECTTP_DR-GROSSWEIGHTUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TECHO, internal->external for field SUPERIORTECHNICALOBJECTLABEL CALL FUNCTION 'CONVERSION_EXIT_TECHO_OUTPUT' EXPORTING input = WA_ISTECHNICALOBJECTTP_DR-SUPERIORTECHNICALOBJECTLABEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISTECHNICALOBJECTTP_DR-SUPERIORTECHNICALOBJECTLABEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field TECHOBJMATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ISTECHNICALOBJECTTP_DR-TECHOBJMATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISTECHNICALOBJECTTP_DR-TECHOBJMATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field TECHOBJSERIALNUMBER CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_ISTECHNICALOBJECTTP_DR-TECHOBJSERIALNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISTECHNICALOBJECTTP_DR-TECHOBJSERIALNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field CONSTRUCTIONMATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ISTECHNICALOBJECTTP_DR-CONSTRUCTIONMATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISTECHNICALOBJECTTP_DR-CONSTRUCTIONMATERIAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISTECHNICALOBJECTTP_DR_STR,
DRAFTUUID TYPE STRING,
TECHNICALOBJECT TYPE STRING,
TECHOBJISEQUIPORFUNCNLLOC TYPE STRING,
TECHNICALOBJECTLABEL TYPE STRING,
ISEQUIPORFUNCNLLOCFOREDIT TYPE STRING,
TECHNICALOBJECTFOREDIT TYPE STRING,
TECHNICALOBJECTCATEGORY TYPE STRING,
EQUIPMENT TYPE STRING,
FUNCTIONALLOCATION TYPE STRING,
TECHNICALOBJECTTYPE TYPE STRING,
CREATEDBYUSER TYPE STRING,
CREATIONDATE TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
LASTCHANGEDATE TYPE STRING,
ASSETMANUFACTURERNAME TYPE STRING,
MANUFACTURERPARTTYPENAME TYPE STRING,
MAINTENANCEPLANNINGPLANT TYPE STRING,
MAINTENANCEPLANNERGROUP TYPE STRING,
CATALOGPROFILE TYPE STRING,
AUTHORIZATIONGROUP TYPE STRING,
WORKCENTERINTERNALID TYPE STRING,
WORKCENTERTYPECODE TYPE STRING,
MAINTOBJECTLOCACCTASSGMTNMBR TYPE STRING,
MANUFACTURERCOUNTRY TYPE STRING,
CONSTRUCTIONYEAR TYPE STRING,
CONSTRUCTIONMONTH TYPE STRING,
ACQUISITIONDATE TYPE STRING,
CURRENCY TYPE STRING,
ACQUISITIONVALUE TYPE STRING,
TECHNICALOBJECTSORTCODE TYPE STRING,
MAINTOBJECTINTERNALID TYPE STRING,
ISDELETED TYPE STRING,
SIZEORDIMENSIONTEXT TYPE STRING,
INVENTORYNUMBER TYPE STRING,
GROSSWEIGHT TYPE STRING,
GROSSWEIGHTUNIT TYPE STRING,
MANUFACTURERPARTNMBR TYPE STRING,
MANUFACTURERSERIALNUMBER TYPE STRING,
TECHNICALOBJECTDESCRIPTION TYPE STRING,
TECHNICALOBJECTHASLONGTEXT TYPE STRING,
SUPERIORTECHNICALOBJECT TYPE STRING,
SUPERIORTECHNICALOBJECTLABEL TYPE STRING,
SUPERIORTECHNICALOBJECTNAME TYPE STRING,
SUPERIOROBJISEQUIPORFUNCNLLOC TYPE STRING,
TECHOBJMATERIAL TYPE STRING,
TECHOBJSERIALNUMBER TYPE STRING,
CONSTRUCTIONMATERIAL TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYCONSISTENCYSTATUS TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,
DUMMY_EQUI_INCL_EEW_PS TYPE STRING,
DUMMY_IFLOT_INCL_EEW_PS TYPE STRING,
ISACTIVEENTITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISTECHNICALOBJECTTP_DR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-DRAFTUUID sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-TECHNICALOBJECT sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-TECHOBJISEQUIPORFUNCNLLOC sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-TECHNICALOBJECTLABEL sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-ISEQUIPORFUNCNLLOCFOREDIT sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-TECHNICALOBJECTFOREDIT sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-TECHNICALOBJECTCATEGORY sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-EQUIPMENT sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-FUNCTIONALLOCATION sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-TECHNICALOBJECTTYPE sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-CREATEDBYUSER sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-CREATIONDATE sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-LASTCHANGEDBYUSER sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-LASTCHANGEDATE sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-ASSETMANUFACTURERNAME sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-MANUFACTURERPARTTYPENAME sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-MAINTENANCEPLANNINGPLANT sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-MAINTENANCEPLANNERGROUP sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-CATALOGPROFILE sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-AUTHORIZATIONGROUP sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-WORKCENTERINTERNALID sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-WORKCENTERTYPECODE sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-MAINTOBJECTLOCACCTASSGMTNMBR sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-MANUFACTURERCOUNTRY sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-CONSTRUCTIONYEAR sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-CONSTRUCTIONMONTH sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-ACQUISITIONDATE sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-CURRENCY sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-ACQUISITIONVALUE sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-TECHNICALOBJECTSORTCODE sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-MAINTOBJECTINTERNALID sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-ISDELETED sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-SIZEORDIMENSIONTEXT sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-INVENTORYNUMBER sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-GROSSWEIGHT sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-GROSSWEIGHTUNIT sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-MANUFACTURERPARTNMBR sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-MANUFACTURERSERIALNUMBER sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-TECHNICALOBJECTDESCRIPTION sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-TECHNICALOBJECTHASLONGTEXT sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-SUPERIORTECHNICALOBJECT sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-SUPERIORTECHNICALOBJECTLABEL sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-SUPERIORTECHNICALOBJECTNAME sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-SUPERIOROBJISEQUIPORFUNCNLLOC sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-TECHOBJMATERIAL sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-TECHOBJSERIALNUMBER sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-CONSTRUCTIONMATERIAL sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-HASACTIVEENTITY sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-DRAFTENTITYCONSISTENCYSTATUS sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-DRAFTENTITYOPERATIONCODE sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-DUMMY_EQUI_INCL_EEW_PS sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-DUMMY_IFLOT_INCL_EEW_PS sy-vline
WA_ISTECHNICALOBJECTTP_DR_STR-ISACTIVEENTITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.