ABAP Select data from SAP table ISTT_TC_OBJ into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISTT_TC_OBJ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISTT_TC_OBJ. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ISTT_TC_OBJ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ISTT_TC_OBJ TYPE STANDARD TABLE OF ISTT_TC_OBJ, WA_ISTT_TC_OBJ TYPE ISTT_TC_OBJ, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ISTT_TC_OBJ> TYPE ISTT_TC_OBJ. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ISTT_TC_OBJ. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ISTT_TC_OBJ INTO TABLE IT_ISTT_TC_OBJ. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ISTT_TC_OBJ * INTO TABLE @DATA(IT_ISTT_TC_OBJ2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ISTT_TC_OBJ INDEX 1 INTO DATA(WA_ISTT_TC_OBJ2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ISTT_TC_OBJ ASSIGNING <ISTT_TC_OBJ>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISTT_TC_OBJ>-CLIENT = 1.
<ISTT_TC_OBJ>-OBJ_GUID = 1.
<ISTT_TC_OBJ>-SERVICE = 1.
<ISTT_TC_OBJ>-PARTNER_GUID = 1.
<ISTT_TC_OBJ>-VKONT = 1.
ENDLOOP. LOOP AT IT_ISTT_TC_OBJ INTO WA_ISTT_TC_OBJ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ISTT_TC_OBJ-ORDER_GUID, sy-vline,
WA_ISTT_TC_OBJ-ORDERPOS_GUID, sy-vline,
WA_ISTT_TC_OBJ-GROUP_ID, sy-vline,
WA_ISTT_TC_OBJ-CANCELED, sy-vline,
WA_ISTT_TC_OBJ-CANCEL_REASON, sy-vline,
WA_ISTT_TC_OBJ-VALID_FROM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISTT_TC_OBJ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISTT_TC_OBJ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISTT_TC_OBJ INTO WA_ISTT_TC_OBJ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field HOME_SYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISTT_TC_OBJ-HOME_SYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISTT_TC_OBJ-HOME_SYSTEM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISTT_TC_OBJ_STR,
CLIENT TYPE STRING,
OBJ_GUID TYPE STRING,
SERVICE TYPE STRING,
PARTNER_GUID TYPE STRING,
VKONT TYPE STRING,
ORDER_GUID TYPE STRING,
ORDERPOS_GUID TYPE STRING,
GROUP_ID TYPE STRING,
CANCELED TYPE STRING,
CANCEL_REASON TYPE STRING,
VALID_FROM TYPE STRING,
VALID_TO TYPE STRING,
LOCKED TYPE STRING,
LOCK_TYPE TYPE STRING,
LOCK_REASON TYPE STRING,
NO_LOCK TYPE STRING,
NO_LOCK_REASON TYPE STRING,
HOME_SYSTEM TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISTT_TC_OBJ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISTT_TC_OBJ_STR-CLIENT sy-vline
WA_ISTT_TC_OBJ_STR-OBJ_GUID sy-vline
WA_ISTT_TC_OBJ_STR-SERVICE sy-vline
WA_ISTT_TC_OBJ_STR-PARTNER_GUID sy-vline
WA_ISTT_TC_OBJ_STR-VKONT sy-vline
WA_ISTT_TC_OBJ_STR-ORDER_GUID sy-vline
WA_ISTT_TC_OBJ_STR-ORDERPOS_GUID sy-vline
WA_ISTT_TC_OBJ_STR-GROUP_ID sy-vline
WA_ISTT_TC_OBJ_STR-CANCELED sy-vline
WA_ISTT_TC_OBJ_STR-CANCEL_REASON sy-vline
WA_ISTT_TC_OBJ_STR-VALID_FROM sy-vline
WA_ISTT_TC_OBJ_STR-VALID_TO sy-vline
WA_ISTT_TC_OBJ_STR-LOCKED sy-vline
WA_ISTT_TC_OBJ_STR-LOCK_TYPE sy-vline
WA_ISTT_TC_OBJ_STR-LOCK_REASON sy-vline
WA_ISTT_TC_OBJ_STR-NO_LOCK sy-vline
WA_ISTT_TC_OBJ_STR-NO_LOCK_REASON sy-vline
WA_ISTT_TC_OBJ_STR-HOME_SYSTEM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.