ABAP Select data from SAP table ISU06_MO_EXTV into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISU06_MO_EXTV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISU06_MO_EXTV. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ISU06_MO_EXTV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ISU06_MO_EXTV TYPE STANDARD TABLE OF ISU06_MO_EXTV, WA_ISU06_MO_EXTV TYPE ISU06_MO_EXTV, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ISU06_MO_EXTV> TYPE ISU06_MO_EXTV. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ISU06_MO_EXTV. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ISU06_MO_EXTV INTO TABLE IT_ISU06_MO_EXTV. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ISU06_MO_EXTV * INTO TABLE @DATA(IT_ISU06_MO_EXTV2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ISU06_MO_EXTV INDEX 1 INTO DATA(WA_ISU06_MO_EXTV2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ISU06_MO_EXTV ASSIGNING <ISU06_MO_EXTV>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISU06_MO_EXTV>-VERTRAG = 1.
<ISU06_MO_EXTV>-EINZDAT = 1.
<ISU06_MO_EXTV>-AUSZDAT = 1.
<ISU06_MO_EXTV>-VKONT = 1.
<ISU06_MO_EXTV>-VBEZ = 1.
ENDLOOP. LOOP AT IT_ISU06_MO_EXTV INTO WA_ISU06_MO_EXTV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ISU06_MO_EXTV-BUKRS, sy-vline,
WA_ISU06_MO_EXTV-KOFIZ, sy-vline,
WA_ISU06_MO_EXTV-GEMFAKT, sy-vline,
WA_ISU06_MO_EXTV-BEZUG, sy-vline,
WA_ISU06_MO_EXTV-EIGENVERBR, sy-vline,
WA_ISU06_MO_EXTV-MANABR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISU06_MO_EXTV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISU06_MO_EXTV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISU06_MO_EXTV INTO WA_ISU06_MO_EXTV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field VERTRAG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISU06_MO_EXTV-VERTRAG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISU06_MO_EXTV-VERTRAG.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISU06_MO_EXTV-VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISU06_MO_EXTV-VKONT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ANLAGE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISU06_MO_EXTV-ANLAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISU06_MO_EXTV-ANLAGE.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VSTELLE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISU06_MO_EXTV-VSTELLE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISU06_MO_EXTV-VSTELLE.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field EIGENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISU06_MO_EXTV-EIGENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISU06_MO_EXTV-EIGENT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISU06_MO_EXTV_STR,
VERTRAG TYPE STRING,
EINZDAT TYPE STRING,
AUSZDAT TYPE STRING,
VKONT TYPE STRING,
VBEZ TYPE STRING,
BUKRS TYPE STRING,
KOFIZ TYPE STRING,
GEMFAKT TYPE STRING,
BEZUG TYPE STRING,
EIGENVERBR TYPE STRING,
MANABR TYPE STRING,
PYPLT TYPE STRING,
PYPLS TYPE STRING,
KZSONDAUSZ TYPE STRING,
AUTEIGEINZ TYPE STRING,
ABSSTOPDAT TYPE STRING,
SCHLFAKT TYPE STRING,
MAHNV TYPE STRING,
MANSP TYPE STRING,
MAHNVUMZ TYPE STRING,
MANOUTSORT TYPE STRING,
EANL_GELESEN TYPE STRING,
ANLAGE TYPE STRING,
AKLASSE TYPE STRING,
SPARTE TYPE STRING,
ANLART TYPE STRING,
PAUSCHAL TYPE STRING,
EVBS_GELESEN TYPE STRING,
VSTELLE TYPE STRING,
VBSART TYPE STRING,
EIGENT TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISU06_MO_EXTV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISU06_MO_EXTV_STR-VERTRAG sy-vline
WA_ISU06_MO_EXTV_STR-EINZDAT sy-vline
WA_ISU06_MO_EXTV_STR-AUSZDAT sy-vline
WA_ISU06_MO_EXTV_STR-VKONT sy-vline
WA_ISU06_MO_EXTV_STR-VBEZ sy-vline
WA_ISU06_MO_EXTV_STR-BUKRS sy-vline
WA_ISU06_MO_EXTV_STR-KOFIZ sy-vline
WA_ISU06_MO_EXTV_STR-GEMFAKT sy-vline
WA_ISU06_MO_EXTV_STR-BEZUG sy-vline
WA_ISU06_MO_EXTV_STR-EIGENVERBR sy-vline
WA_ISU06_MO_EXTV_STR-MANABR sy-vline
WA_ISU06_MO_EXTV_STR-PYPLT sy-vline
WA_ISU06_MO_EXTV_STR-PYPLS sy-vline
WA_ISU06_MO_EXTV_STR-KZSONDAUSZ sy-vline
WA_ISU06_MO_EXTV_STR-AUTEIGEINZ sy-vline
WA_ISU06_MO_EXTV_STR-ABSSTOPDAT sy-vline
WA_ISU06_MO_EXTV_STR-SCHLFAKT sy-vline
WA_ISU06_MO_EXTV_STR-MAHNV sy-vline
WA_ISU06_MO_EXTV_STR-MANSP sy-vline
WA_ISU06_MO_EXTV_STR-MAHNVUMZ sy-vline
WA_ISU06_MO_EXTV_STR-MANOUTSORT sy-vline
WA_ISU06_MO_EXTV_STR-EANL_GELESEN sy-vline
WA_ISU06_MO_EXTV_STR-ANLAGE sy-vline
WA_ISU06_MO_EXTV_STR-AKLASSE sy-vline
WA_ISU06_MO_EXTV_STR-SPARTE sy-vline
WA_ISU06_MO_EXTV_STR-ANLART sy-vline
WA_ISU06_MO_EXTV_STR-PAUSCHAL sy-vline
WA_ISU06_MO_EXTV_STR-EVBS_GELESEN sy-vline
WA_ISU06_MO_EXTV_STR-VSTELLE sy-vline
WA_ISU06_MO_EXTV_STR-VBSART sy-vline
WA_ISU06_MO_EXTV_STR-EIGENT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.