ABAP Select data from SAP table ISU_BWPROT_DISP_SELECTION into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISU_BWPROT_DISP_SELECTION table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISU_BWPROT_DISP_SELECTION. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISU_BWPROT_DISP_SELECTION table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISU_BWPROT_DISP_SELECTION TYPE STANDARD TABLE OF ISU_BWPROT_DISP_SELECTION,
      WA_ISU_BWPROT_DISP_SELECTION TYPE ISU_BWPROT_DISP_SELECTION,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISU_BWPROT_DISP_SELECTION> TYPE ISU_BWPROT_DISP_SELECTION.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISU_BWPROT_DISP_SELECTION.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISU_BWPROT_DISP_SELECTION
  INTO TABLE IT_ISU_BWPROT_DISP_SELECTION.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISU_BWPROT_DISP_SELECTION
*  INTO TABLE @DATA(IT_ISU_BWPROT_DISP_SELECTION2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISU_BWPROT_DISP_SELECTION INDEX 1 INTO DATA(WA_ISU_BWPROT_DISP_SELECTION2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISU_BWPROT_DISP_SELECTION ASSIGNING <ISU_BWPROT_DISP_SELECTION>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISU_BWPROT_DISP_SELECTION>-HEADER_TEXT = 1.
<ISU_BWPROT_DISP_SELECTION>-LIST_TITLE = 1.
<ISU_BWPROT_DISP_SELECTION>-MAX_RECORDS = 1.
<ISU_BWPROT_DISP_SELECTION>-XBWPROT_SEL = 1.
<ISU_BWPROT_DISP_SELECTION>-XBWPROTE_SEL = 1.
ENDLOOP.

LOOP AT IT_ISU_BWPROT_DISP_SELECTION INTO WA_ISU_BWPROT_DISP_SELECTION.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISU_BWPROT_DISP_SELECTION-XBWPROTH_SEL, sy-vline,
WA_ISU_BWPROT_DISP_SELECTION-FIKEY_RANGES, sy-vline,
WA_ISU_BWPROT_DISP_SELECTION-BUDAT_RANGES, sy-vline,
WA_ISU_BWPROT_DISP_SELECTION-OPBEL_RANGES, sy-vline,
WA_ISU_BWPROT_DISP_SELECTION-DATAS_RANGES, sy-vline,
WA_ISU_BWPROT_DISP_SELECTION-CPUDT_RANGES, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISU_BWPROT_DISP_SELECTION you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISU_BWPROT_DISP_SELECTION TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISU_BWPROT_DISP_SELECTION INTO WA_ISU_BWPROT_DISP_SELECTION. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISU_BWPROT_DISP_SELECTION_STR,
HEADER_TEXT TYPE STRING,
LIST_TITLE TYPE STRING,
MAX_RECORDS TYPE STRING,
XBWPROT_SEL TYPE STRING,
XBWPROTE_SEL TYPE STRING,
XBWPROTH_SEL TYPE STRING,
FIKEY_RANGES TYPE STRING,
BUDAT_RANGES TYPE STRING,
OPBEL_RANGES TYPE STRING,
DATAS_RANGES TYPE STRING,
CPUDT_RANGES TYPE STRING,
UPDMODE_RANGES TYPE STRING,
EXDAT_RANGES TYPE STRING,
REQUNR_RANGES TYPE STRING,
BWSTATUS_RANGES TYPE STRING,
WHERE_TAB TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISU_BWPROT_DISP_SELECTION_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-HEADER_TEXT sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-LIST_TITLE sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-MAX_RECORDS sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-XBWPROT_SEL sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-XBWPROTE_SEL sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-XBWPROTH_SEL sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-FIKEY_RANGES sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-BUDAT_RANGES sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-OPBEL_RANGES sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-DATAS_RANGES sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-CPUDT_RANGES sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-UPDMODE_RANGES sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-EXDAT_RANGES sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-REQUNR_RANGES sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-BWSTATUS_RANGES sy-vline
WA_ISU_BWPROT_DISP_SELECTION_STR-WHERE_TAB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.