ABAP Select data from SAP table ISUCIC_TYPE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISUCIC_TYPE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISUCIC_TYPE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISUCIC_TYPE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISUCIC_TYPE TYPE STANDARD TABLE OF ISUCIC_TYPE,
      WA_ISUCIC_TYPE TYPE ISUCIC_TYPE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISUCIC_TYPE> TYPE ISUCIC_TYPE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISUCIC_TYPE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISUCIC_TYPE
  INTO TABLE IT_ISUCIC_TYPE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISUCIC_TYPE
*  INTO TABLE @DATA(IT_ISUCIC_TYPE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISUCIC_TYPE INDEX 1 INTO DATA(WA_ISUCIC_TYPE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISUCIC_TYPE ASSIGNING <ISUCIC_TYPE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISUCIC_TYPE>-HROBJID = 1.
<ISUCIC_TYPE>-CICFRPROF = 1.
<ISUCIC_TYPE>-STEXT = 1.
<ISUCIC_TYPE>-OBJEKTID = 1.
<ISUCIC_TYPE>-CICSLOTNO = 1.
ENDLOOP.

LOOP AT IT_ISUCIC_TYPE INTO WA_ISUCIC_TYPE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISUCIC_TYPE-PROGRAMM, sy-vline,
WA_ISUCIC_TYPE-EBA_RNAME_SFX, sy-vline,
WA_ISUCIC_TYPE-CCMCCONTPROF, sy-vline,
WA_ISUCIC_TYPE-CCMCCONTLABEL, sy-vline,
WA_ISUCIC_TYPE-CICCOMPV, sy-vline,
WA_ISUCIC_TYPE-LAND1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISUCIC_TYPE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISUCIC_TYPE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISUCIC_TYPE INTO WA_ISUCIC_TYPE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AD_ADDRNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISUCIC_TYPE-AD_ADDRNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISUCIC_TYPE-AD_ADDRNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AD_PERSNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISUCIC_TYPE-AD_PERSNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISUCIC_TYPE-AD_PERSNUM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISUCIC_TYPE_STR,
HROBJID TYPE STRING,
CICFRPROF TYPE STRING,
STEXT TYPE STRING,
OBJEKTID TYPE STRING,
CICSLOTNO TYPE STRING,
PROGRAMM TYPE STRING,
EBA_RNAME_SFX TYPE STRING,
CCMCCONTPROF TYPE STRING,
CCMCCONTLABEL TYPE STRING,
CICCOMPV TYPE STRING,
LAND1 TYPE STRING,
RFCDEST TYPE STRING,
CCMQUEUENAME TYPE STRING,
CCMCTIADMPROFILE TYPE STRING,
CCMCTIPROFILE TYPE STRING,
SWC_VALUE TYPE STRING,
SWC_REFFLD TYPE STRING,
SWC_REFSTR TYPE STRING,
CCMSRCHTYPE TYPE STRING,
CCMCSPROFILE TYPE STRING,
CCMSRCHFLD TYPE STRING,
AD_ADDRNUM TYPE STRING,
AD_PERSNUM TYPE STRING,
AD_ADRTYPE TYPE STRING,
GUI_TEXT TYPE STRING,
EWCOMIF TYPE STRING,
SWO_TYPEID TYPE STRING,
SWO_REFOBJ TYPE STRING,
RS38L_FNAM TYPE STRING,
XUVALUE TYPE STRING,
D0100_MAPN TYPE STRING,
NUMC3 TYPE STRING,
BOOLEAN TYPE STRING,
CHAR1 TYPE STRING,
CHAR20 TYPE STRING,
CICCOMPID TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISUCIC_TYPE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISUCIC_TYPE_STR-HROBJID sy-vline
WA_ISUCIC_TYPE_STR-CICFRPROF sy-vline
WA_ISUCIC_TYPE_STR-STEXT sy-vline
WA_ISUCIC_TYPE_STR-OBJEKTID sy-vline
WA_ISUCIC_TYPE_STR-CICSLOTNO sy-vline
WA_ISUCIC_TYPE_STR-PROGRAMM sy-vline
WA_ISUCIC_TYPE_STR-EBA_RNAME_SFX sy-vline
WA_ISUCIC_TYPE_STR-CCMCCONTPROF sy-vline
WA_ISUCIC_TYPE_STR-CCMCCONTLABEL sy-vline
WA_ISUCIC_TYPE_STR-CICCOMPV sy-vline
WA_ISUCIC_TYPE_STR-LAND1 sy-vline
WA_ISUCIC_TYPE_STR-RFCDEST sy-vline
WA_ISUCIC_TYPE_STR-CCMQUEUENAME sy-vline
WA_ISUCIC_TYPE_STR-CCMCTIADMPROFILE sy-vline
WA_ISUCIC_TYPE_STR-CCMCTIPROFILE sy-vline
WA_ISUCIC_TYPE_STR-SWC_VALUE sy-vline
WA_ISUCIC_TYPE_STR-SWC_REFFLD sy-vline
WA_ISUCIC_TYPE_STR-SWC_REFSTR sy-vline
WA_ISUCIC_TYPE_STR-CCMSRCHTYPE sy-vline
WA_ISUCIC_TYPE_STR-CCMCSPROFILE sy-vline
WA_ISUCIC_TYPE_STR-CCMSRCHFLD sy-vline
WA_ISUCIC_TYPE_STR-AD_ADDRNUM sy-vline
WA_ISUCIC_TYPE_STR-AD_PERSNUM sy-vline
WA_ISUCIC_TYPE_STR-AD_ADRTYPE sy-vline
WA_ISUCIC_TYPE_STR-GUI_TEXT sy-vline
WA_ISUCIC_TYPE_STR-EWCOMIF sy-vline
WA_ISUCIC_TYPE_STR-SWO_TYPEID sy-vline
WA_ISUCIC_TYPE_STR-SWO_REFOBJ sy-vline
WA_ISUCIC_TYPE_STR-RS38L_FNAM sy-vline
WA_ISUCIC_TYPE_STR-XUVALUE sy-vline
WA_ISUCIC_TYPE_STR-D0100_MAPN sy-vline
WA_ISUCIC_TYPE_STR-NUMC3 sy-vline
WA_ISUCIC_TYPE_STR-BOOLEAN sy-vline
WA_ISUCIC_TYPE_STR-CHAR1 sy-vline
WA_ISUCIC_TYPE_STR-CHAR20 sy-vline
WA_ISUCIC_TYPE_STR-CICCOMPID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.