ABAP Select data from SAP table ISUPLEVALREQQST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ISUPLEVALREQQST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ISUPLEVALREQQST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ISUPLEVALREQQST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ISUPLEVALREQQST TYPE STANDARD TABLE OF ISUPLEVALREQQST,
      WA_ISUPLEVALREQQST TYPE ISUPLEVALREQQST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ISUPLEVALREQQST> TYPE ISUPLEVALREQQST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ISUPLEVALREQQST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ISUPLEVALREQQST
  INTO TABLE IT_ISUPLEVALREQQST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ISUPLEVALREQQST
*  INTO TABLE @DATA(IT_ISUPLEVALREQQST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ISUPLEVALREQQST INDEX 1 INTO DATA(WA_ISUPLEVALREQQST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ISUPLEVALREQQST ASSIGNING <ISUPLEVALREQQST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ISUPLEVALREQQST>-MANDT = 1.
<ISUPLEVALREQQST>-SUPLREVALREQQUESTIONUUID = 1.
<ISUPLEVALREQQST>-SUPLREVALREQUUID = 1.
<ISUPLEVALREQQST>-SUPLREVALREQSECTIONUUID = 1.
<ISUPLEVALREQQST>-SUPLREVALREQBRNCHGQUESTION = 1.
ENDLOOP.

LOOP AT IT_ISUPLEVALREQQST INTO WA_ISUPLEVALREQQST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ISUPLEVALREQQST-SUPLREVALQUESTIONUUID, sy-vline,
WA_ISUPLEVALREQQST-SUPPLIEREVALQUESTION, sy-vline,
WA_ISUPLEVALREQQST-SUPPLIEREVALREQUESTQUESTION, sy-vline,
WA_ISUPLEVALREQQST-QUESTIONNAME, sy-vline,
WA_ISUPLEVALREQQST-SLCQUESTIONTYPE, sy-vline,
WA_ISUPLEVALREQQST-MINIMALSCORE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ISUPLEVALREQQST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ISUPLEVALREQQST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ISUPLEVALREQQST INTO WA_ISUPLEVALREQQST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SUPLREVALREQBRNCHGQUESTION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISUPLEVALREQQST-SUPLREVALREQBRNCHGQUESTION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISUPLEVALREQQST-SUPLREVALREQBRNCHGQUESTION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUPPLIEREVALQUESTION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISUPLEVALREQQST-SUPPLIEREVALQUESTION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISUPLEVALREQQST-SUPPLIEREVALQUESTION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUPPLIEREVALREQUESTQUESTION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ISUPLEVALREQQST-SUPPLIEREVALREQUESTQUESTION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ISUPLEVALREQQST-SUPPLIEREVALREQUESTQUESTION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ISUPLEVALREQQST_STR,
MANDT TYPE STRING,
SUPLREVALREQQUESTIONUUID TYPE STRING,
SUPLREVALREQUUID TYPE STRING,
SUPLREVALREQSECTIONUUID TYPE STRING,
SUPLREVALREQBRNCHGQUESTION TYPE STRING,
SUPLREVALQUESTIONUUID TYPE STRING,
SUPPLIEREVALQUESTION TYPE STRING,
SUPPLIEREVALREQUESTQUESTION TYPE STRING,
QUESTIONNAME TYPE STRING,
SLCQUESTIONTYPE TYPE STRING,
MINIMALSCORE TYPE STRING,
TARGETSCORE TYPE STRING,
SLCQUESTIONATTACHMENTOPTION TYPE STRING,
ISDISQUALIFYINGQUESTION TYPE STRING,
SLCPREFERREDANSWER TYPE STRING,
NUMBEROFRESPONSES TYPE STRING,
ISQUESTIONCOMMENTENABLED TYPE STRING,
SUPLREVALORDINALNUMBER TYPE STRING,
ISMANDATORYQUESTION TYPE STRING,END OF T_EKKO_STR. DATA: WA_ISUPLEVALREQQST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ISUPLEVALREQQST_STR-MANDT sy-vline
WA_ISUPLEVALREQQST_STR-SUPLREVALREQQUESTIONUUID sy-vline
WA_ISUPLEVALREQQST_STR-SUPLREVALREQUUID sy-vline
WA_ISUPLEVALREQQST_STR-SUPLREVALREQSECTIONUUID sy-vline
WA_ISUPLEVALREQQST_STR-SUPLREVALREQBRNCHGQUESTION sy-vline
WA_ISUPLEVALREQQST_STR-SUPLREVALQUESTIONUUID sy-vline
WA_ISUPLEVALREQQST_STR-SUPPLIEREVALQUESTION sy-vline
WA_ISUPLEVALREQQST_STR-SUPPLIEREVALREQUESTQUESTION sy-vline
WA_ISUPLEVALREQQST_STR-QUESTIONNAME sy-vline
WA_ISUPLEVALREQQST_STR-SLCQUESTIONTYPE sy-vline
WA_ISUPLEVALREQQST_STR-MINIMALSCORE sy-vline
WA_ISUPLEVALREQQST_STR-TARGETSCORE sy-vline
WA_ISUPLEVALREQQST_STR-SLCQUESTIONATTACHMENTOPTION sy-vline
WA_ISUPLEVALREQQST_STR-ISDISQUALIFYINGQUESTION sy-vline
WA_ISUPLEVALREQQST_STR-SLCPREFERREDANSWER sy-vline
WA_ISUPLEVALREQQST_STR-NUMBEROFRESPONSES sy-vline
WA_ISUPLEVALREQQST_STR-ISQUESTIONCOMMENTENABLED sy-vline
WA_ISUPLEVALREQQST_STR-SUPLREVALORDINALNUMBER sy-vline
WA_ISUPLEVALREQQST_STR-ISMANDATORYQUESTION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.