ABAP Select data from SAP table IUUC_S4P_VBAKS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP IUUC_S4P_VBAKS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IUUC_S4P_VBAKS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the IUUC_S4P_VBAKS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_IUUC_S4P_VBAKS TYPE STANDARD TABLE OF IUUC_S4P_VBAKS,
      WA_IUUC_S4P_VBAKS TYPE IUUC_S4P_VBAKS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <IUUC_S4P_VBAKS> TYPE IUUC_S4P_VBAKS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_IUUC_S4P_VBAKS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM IUUC_S4P_VBAKS
  INTO TABLE IT_IUUC_S4P_VBAKS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM IUUC_S4P_VBAKS
*  INTO TABLE @DATA(IT_IUUC_S4P_VBAKS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_IUUC_S4P_VBAKS INDEX 1 INTO DATA(WA_IUUC_S4P_VBAKS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_IUUC_S4P_VBAKS ASSIGNING <IUUC_S4P_VBAKS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<IUUC_S4P_VBAKS>-MANDT = 1.
<IUUC_S4P_VBAKS>-PACKID = 1.
<IUUC_S4P_VBAKS>-VBELN = 1.
<IUUC_S4P_VBAKS>-ABSTK = 1.
<IUUC_S4P_VBAKS>-BESTK = 1.
ENDLOOP.

LOOP AT IT_IUUC_S4P_VBAKS INTO WA_IUUC_S4P_VBAKS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_IUUC_S4P_VBAKS-CMPSC, sy-vline,
WA_IUUC_S4P_VBAKS-CMPSD, sy-vline,
WA_IUUC_S4P_VBAKS-CMPSI, sy-vline,
WA_IUUC_S4P_VBAKS-CMPSJ, sy-vline,
WA_IUUC_S4P_VBAKS-CMPSK, sy-vline,
WA_IUUC_S4P_VBAKS-CMPS_CM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IUUC_S4P_VBAKS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IUUC_S4P_VBAKS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IUUC_S4P_VBAKS INTO WA_IUUC_S4P_VBAKS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IUUC_S4P_VBAKS_STR,
MANDT TYPE STRING,
PACKID TYPE STRING,
VBELN TYPE STRING,
ABSTK TYPE STRING,
BESTK TYPE STRING,
CMPSC TYPE STRING,
CMPSD TYPE STRING,
CMPSI TYPE STRING,
CMPSJ TYPE STRING,
CMPSK TYPE STRING,
CMPS_CM TYPE STRING,
CMPS_TE TYPE STRING,
CMGST TYPE STRING,
COSTA TYPE STRING,
DCSTK TYPE STRING,
FKSAK TYPE STRING,
FMSTK TYPE STRING,
FSSTK TYPE STRING,
GBSTK TYPE STRING,
LFGSK TYPE STRING,
LFSTK TYPE STRING,
LSSTK TYPE STRING,
MANEK TYPE STRING,
RFGSK TYPE STRING,
RFSTK TYPE STRING,
SPSTG TYPE STRING,
TRSTA TYPE STRING,
UVALL TYPE STRING,
UVALS TYPE STRING,
UVFAK TYPE STRING,
UVFAS TYPE STRING,
UVPRS TYPE STRING,
UVVLK TYPE STRING,
UVVLS TYPE STRING,
UVK01 TYPE STRING,
UVK02 TYPE STRING,
UVK03 TYPE STRING,
UVK04 TYPE STRING,
UVK05 TYPE STRING,
UVS01 TYPE STRING,
UVS02 TYPE STRING,
UVS03 TYPE STRING,
UVS04 TYPE STRING,
UVS05 TYPE STRING,END OF T_EKKO_STR. DATA: WA_IUUC_S4P_VBAKS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IUUC_S4P_VBAKS_STR-MANDT sy-vline
WA_IUUC_S4P_VBAKS_STR-PACKID sy-vline
WA_IUUC_S4P_VBAKS_STR-VBELN sy-vline
WA_IUUC_S4P_VBAKS_STR-ABSTK sy-vline
WA_IUUC_S4P_VBAKS_STR-BESTK sy-vline
WA_IUUC_S4P_VBAKS_STR-CMPSC sy-vline
WA_IUUC_S4P_VBAKS_STR-CMPSD sy-vline
WA_IUUC_S4P_VBAKS_STR-CMPSI sy-vline
WA_IUUC_S4P_VBAKS_STR-CMPSJ sy-vline
WA_IUUC_S4P_VBAKS_STR-CMPSK sy-vline
WA_IUUC_S4P_VBAKS_STR-CMPS_CM sy-vline
WA_IUUC_S4P_VBAKS_STR-CMPS_TE sy-vline
WA_IUUC_S4P_VBAKS_STR-CMGST sy-vline
WA_IUUC_S4P_VBAKS_STR-COSTA sy-vline
WA_IUUC_S4P_VBAKS_STR-DCSTK sy-vline
WA_IUUC_S4P_VBAKS_STR-FKSAK sy-vline
WA_IUUC_S4P_VBAKS_STR-FMSTK sy-vline
WA_IUUC_S4P_VBAKS_STR-FSSTK sy-vline
WA_IUUC_S4P_VBAKS_STR-GBSTK sy-vline
WA_IUUC_S4P_VBAKS_STR-LFGSK sy-vline
WA_IUUC_S4P_VBAKS_STR-LFSTK sy-vline
WA_IUUC_S4P_VBAKS_STR-LSSTK sy-vline
WA_IUUC_S4P_VBAKS_STR-MANEK sy-vline
WA_IUUC_S4P_VBAKS_STR-RFGSK sy-vline
WA_IUUC_S4P_VBAKS_STR-RFSTK sy-vline
WA_IUUC_S4P_VBAKS_STR-SPSTG sy-vline
WA_IUUC_S4P_VBAKS_STR-TRSTA sy-vline
WA_IUUC_S4P_VBAKS_STR-UVALL sy-vline
WA_IUUC_S4P_VBAKS_STR-UVALS sy-vline
WA_IUUC_S4P_VBAKS_STR-UVFAK sy-vline
WA_IUUC_S4P_VBAKS_STR-UVFAS sy-vline
WA_IUUC_S4P_VBAKS_STR-UVPRS sy-vline
WA_IUUC_S4P_VBAKS_STR-UVVLK sy-vline
WA_IUUC_S4P_VBAKS_STR-UVVLS sy-vline
WA_IUUC_S4P_VBAKS_STR-UVK01 sy-vline
WA_IUUC_S4P_VBAKS_STR-UVK02 sy-vline
WA_IUUC_S4P_VBAKS_STR-UVK03 sy-vline
WA_IUUC_S4P_VBAKS_STR-UVK04 sy-vline
WA_IUUC_S4P_VBAKS_STR-UVK05 sy-vline
WA_IUUC_S4P_VBAKS_STR-UVS01 sy-vline
WA_IUUC_S4P_VBAKS_STR-UVS02 sy-vline
WA_IUUC_S4P_VBAKS_STR-UVS03 sy-vline
WA_IUUC_S4P_VBAKS_STR-UVS04 sy-vline
WA_IUUC_S4P_VBAKS_STR-UVS05 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.