ABAP Select data from SAP table IUUC_S_KB_XPRA_GEN into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP IUUC_S_KB_XPRA_GEN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to IUUC_S_KB_XPRA_GEN. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the IUUC_S_KB_XPRA_GEN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_IUUC_S_KB_XPRA_GEN TYPE STANDARD TABLE OF IUUC_S_KB_XPRA_GEN, WA_IUUC_S_KB_XPRA_GEN TYPE IUUC_S_KB_XPRA_GEN, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <IUUC_S_KB_XPRA_GEN> TYPE IUUC_S_KB_XPRA_GEN. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_IUUC_S_KB_XPRA_GEN. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM IUUC_S_KB_XPRA_GEN INTO TABLE IT_IUUC_S_KB_XPRA_GEN. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM IUUC_S_KB_XPRA_GEN * INTO TABLE @DATA(IT_IUUC_S_KB_XPRA_GEN2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_IUUC_S_KB_XPRA_GEN INDEX 1 INTO DATA(WA_IUUC_S_KB_XPRA_GEN2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_IUUC_S_KB_XPRA_GEN ASSIGNING <IUUC_S_KB_XPRA_GEN>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<IUUC_S_KB_XPRA_GEN>-ICON = 1.
<IUUC_S_KB_XPRA_GEN>-MT_ID = 1.
<IUUC_S_KB_XPRA_GEN>-XPRA_NAME = 1.
<IUUC_S_KB_XPRA_GEN>-UPGR_RELEASE = 1.
<IUUC_S_KB_XPRA_GEN>-EXECUTION_TYPE = 1.
ENDLOOP. LOOP AT IT_IUUC_S_KB_XPRA_GEN INTO WA_IUUC_S_KB_XPRA_GEN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_IUUC_S_KB_XPRA_GEN-SHORT_TEXT, sy-vline,
WA_IUUC_S_KB_XPRA_GEN-DEVCLASS, sy-vline,
WA_IUUC_S_KB_XPRA_GEN-APPL_COMPONENT, sy-vline,
WA_IUUC_S_KB_XPRA_GEN-SOFTW_COMPONENT, sy-vline,
WA_IUUC_S_KB_XPRA_GEN-DETAILS, sy-vline,
WA_IUUC_S_KB_XPRA_GEN-CLIENT_DEPENDENT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_IUUC_S_KB_XPRA_GEN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_IUUC_S_KB_XPRA_GEN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_IUUC_S_KB_XPRA_GEN INTO WA_IUUC_S_KB_XPRA_GEN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_IUUC_S_KB_XPRA_GEN_STR,
ICON TYPE STRING,
MT_ID TYPE STRING,
XPRA_NAME TYPE STRING,
UPGR_RELEASE TYPE STRING,
EXECUTION_TYPE TYPE STRING,
SHORT_TEXT TYPE STRING,
DEVCLASS TYPE STRING,
APPL_COMPONENT TYPE STRING,
SOFTW_COMPONENT TYPE STRING,
DETAILS TYPE STRING,
CLIENT_DEPENDENT TYPE STRING,
GEN_CODING TYPE STRING,
GEN_TABLES TYPE STRING,
GEN_DDIC_OTHER TYPE STRING,
CODE_SCANN_ADEQ TYPE STRING,
SEQUENCE_CRITICL TYPE STRING,
SPECIAL_CHECK TYPE STRING,
TABLES_ANALYZED TYPE STRING,
XPRA_PHASE_1 TYPE STRING,
RESTART_LOGIC TYPE STRING,
CRE_CHANGE_DOCS TYPE STRING,
CHANGE_NRIV_OBJ TYPE STRING,END OF T_EKKO_STR. DATA: WA_IUUC_S_KB_XPRA_GEN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-ICON sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-MT_ID sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-XPRA_NAME sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-UPGR_RELEASE sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-EXECUTION_TYPE sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-SHORT_TEXT sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-DEVCLASS sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-APPL_COMPONENT sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-SOFTW_COMPONENT sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-DETAILS sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-CLIENT_DEPENDENT sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-GEN_CODING sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-GEN_TABLES sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-GEN_DDIC_OTHER sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-CODE_SCANN_ADEQ sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-SEQUENCE_CRITICL sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-SPECIAL_CHECK sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-TABLES_ANALYZED sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-XPRA_PHASE_1 sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-RESTART_LOGIC sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-CRE_CHANGE_DOCS sy-vline
WA_IUUC_S_KB_XPRA_GEN_STR-CHANGE_NRIV_OBJ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.