ABAP Select data from SAP table J_1BCTE_IF_AQUAV into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP J_1BCTE_IF_AQUAV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to J_1BCTE_IF_AQUAV. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the J_1BCTE_IF_AQUAV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_J_1BCTE_IF_AQUAV TYPE STANDARD TABLE OF J_1BCTE_IF_AQUAV, WA_J_1BCTE_IF_AQUAV TYPE J_1BCTE_IF_AQUAV, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <J_1BCTE_IF_AQUAV> TYPE J_1BCTE_IF_AQUAV. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_J_1BCTE_IF_AQUAV. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM J_1BCTE_IF_AQUAV INTO TABLE IT_J_1BCTE_IF_AQUAV. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM J_1BCTE_IF_AQUAV * INTO TABLE @DATA(IT_J_1BCTE_IF_AQUAV2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_J_1BCTE_IF_AQUAV INDEX 1 INTO DATA(WA_J_1BCTE_IF_AQUAV2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_J_1BCTE_IF_AQUAV ASSIGNING <J_1BCTE_IF_AQUAV>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<J_1BCTE_IF_AQUAV>-V_PREST = 1.
<J_1BCTE_IF_AQUAV>-V_AFRMM = 1.
<J_1BCTE_IF_AQUAV>-N_BOOKING = 1.
<J_1BCTE_IF_AQUAV>-N_CTRL = 1.
<J_1BCTE_IF_AQUAV>-X_NAVIO = 1.
ENDLOOP. LOOP AT IT_J_1BCTE_IF_AQUAV INTO WA_J_1BCTE_IF_AQUAV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_J_1BCTE_IF_AQUAV-TEXT_ID_BALSA, sy-vline,
WA_J_1BCTE_IF_AQUAV-N_VIAG, sy-vline,
WA_J_1BCTE_IF_AQUAV-DIREC, sy-vline,
WA_J_1BCTE_IF_AQUAV-PRT_EMB, sy-vline,
WA_J_1BCTE_IF_AQUAV-PRT_TRANS, sy-vline,
WA_J_1BCTE_IF_AQUAV-PRT_DEST, sy-vline.
ENDLOOP. *Add any further fields from structure WA_J_1BCTE_IF_AQUAV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_J_1BCTE_IF_AQUAV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_J_1BCTE_IF_AQUAV INTO WA_J_1BCTE_IF_AQUAV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_J_1BCTE_IF_AQUAV_STR,
V_PREST TYPE STRING,
V_AFRMM TYPE STRING,
N_BOOKING TYPE STRING,
N_CTRL TYPE STRING,
X_NAVIO TYPE STRING,
TEXT_ID_BALSA TYPE STRING,
N_VIAG TYPE STRING,
DIREC TYPE STRING,
PRT_EMB TYPE STRING,
PRT_TRANS TYPE STRING,
PRT_DEST TYPE STRING,
TP_NAV TYPE STRING,
IRIN TYPE STRING,END OF T_EKKO_STR. DATA: WA_J_1BCTE_IF_AQUAV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_J_1BCTE_IF_AQUAV_STR-V_PREST sy-vline
WA_J_1BCTE_IF_AQUAV_STR-V_AFRMM sy-vline
WA_J_1BCTE_IF_AQUAV_STR-N_BOOKING sy-vline
WA_J_1BCTE_IF_AQUAV_STR-N_CTRL sy-vline
WA_J_1BCTE_IF_AQUAV_STR-X_NAVIO sy-vline
WA_J_1BCTE_IF_AQUAV_STR-TEXT_ID_BALSA sy-vline
WA_J_1BCTE_IF_AQUAV_STR-N_VIAG sy-vline
WA_J_1BCTE_IF_AQUAV_STR-DIREC sy-vline
WA_J_1BCTE_IF_AQUAV_STR-PRT_EMB sy-vline
WA_J_1BCTE_IF_AQUAV_STR-PRT_TRANS sy-vline
WA_J_1BCTE_IF_AQUAV_STR-PRT_DEST sy-vline
WA_J_1BCTE_IF_AQUAV_STR-TP_NAV sy-vline
WA_J_1BCTE_IF_AQUAV_STR-IRIN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.