ABAP Select data from SAP table J_1BEFDS_C_2_C500 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP J_1BEFDS_C_2_C500 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to J_1BEFDS_C_2_C500. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the J_1BEFDS_C_2_C500 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_J_1BEFDS_C_2_C500 TYPE STANDARD TABLE OF J_1BEFDS_C_2_C500,
      WA_J_1BEFDS_C_2_C500 TYPE J_1BEFDS_C_2_C500,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <J_1BEFDS_C_2_C500> TYPE J_1BEFDS_C_2_C500.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_J_1BEFDS_C_2_C500.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM J_1BEFDS_C_2_C500
  INTO TABLE IT_J_1BEFDS_C_2_C500.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM J_1BEFDS_C_2_C500
*  INTO TABLE @DATA(IT_J_1BEFDS_C_2_C5002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_J_1BEFDS_C_2_C500 INDEX 1 INTO DATA(WA_J_1BEFDS_C_2_C5002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_J_1BEFDS_C_2_C500 ASSIGNING <J_1BEFDS_C_2_C500>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<J_1BEFDS_C_2_C500>-REG = 1.
<J_1BEFDS_C_2_C500>-IND_OPER = 1.
<J_1BEFDS_C_2_C500>-IND_EMIT = 1.
<J_1BEFDS_C_2_C500>-COD_PART = 1.
<J_1BEFDS_C_2_C500>-COD_MOD = 1.
ENDLOOP.

LOOP AT IT_J_1BEFDS_C_2_C500 INTO WA_J_1BEFDS_C_2_C500.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_J_1BEFDS_C_2_C500-COD_SIT, sy-vline,
WA_J_1BEFDS_C_2_C500-SER, sy-vline,
WA_J_1BEFDS_C_2_C500-SUB, sy-vline,
WA_J_1BEFDS_C_2_C500-COD_CONS, sy-vline,
WA_J_1BEFDS_C_2_C500-NUM_DOC, sy-vline,
WA_J_1BEFDS_C_2_C500-DT_DOC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_J_1BEFDS_C_2_C500 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_J_1BEFDS_C_2_C500 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_J_1BEFDS_C_2_C500 INTO WA_J_1BEFDS_C_2_C500. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_J_1BEFDS_C_2_C500_STR,
REG TYPE STRING,
IND_OPER TYPE STRING,
IND_EMIT TYPE STRING,
COD_PART TYPE STRING,
COD_MOD TYPE STRING,
COD_SIT TYPE STRING,
SER TYPE STRING,
SUB TYPE STRING,
COD_CONS TYPE STRING,
NUM_DOC TYPE STRING,
DT_DOC TYPE STRING,
DT_E_S TYPE STRING,
VL_DOC TYPE STRING,
VL_DESC TYPE STRING,
VL_FORN TYPE STRING,
VL_SERV_NT TYPE STRING,
VL_TERC TYPE STRING,
VL_DA TYPE STRING,
VL_BC_ICMS TYPE STRING,
VL_ICMS TYPE STRING,
VL_BC_ICMS_ST TYPE STRING,
VL_ICMS_ST TYPE STRING,
COD_INF TYPE STRING,
VL_PIS TYPE STRING,
VL_COFINS TYPE STRING,
TP_CONNECTION TYPE STRING,
COD_TENSION_GROUP TYPE STRING,
TAB_C510 TYPE STRING,
TAB_C590 TYPE STRING,
TAB_CUST TYPE STRING,END OF T_EKKO_STR. DATA: WA_J_1BEFDS_C_2_C500_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_J_1BEFDS_C_2_C500_STR-REG sy-vline
WA_J_1BEFDS_C_2_C500_STR-IND_OPER sy-vline
WA_J_1BEFDS_C_2_C500_STR-IND_EMIT sy-vline
WA_J_1BEFDS_C_2_C500_STR-COD_PART sy-vline
WA_J_1BEFDS_C_2_C500_STR-COD_MOD sy-vline
WA_J_1BEFDS_C_2_C500_STR-COD_SIT sy-vline
WA_J_1BEFDS_C_2_C500_STR-SER sy-vline
WA_J_1BEFDS_C_2_C500_STR-SUB sy-vline
WA_J_1BEFDS_C_2_C500_STR-COD_CONS sy-vline
WA_J_1BEFDS_C_2_C500_STR-NUM_DOC sy-vline
WA_J_1BEFDS_C_2_C500_STR-DT_DOC sy-vline
WA_J_1BEFDS_C_2_C500_STR-DT_E_S sy-vline
WA_J_1BEFDS_C_2_C500_STR-VL_DOC sy-vline
WA_J_1BEFDS_C_2_C500_STR-VL_DESC sy-vline
WA_J_1BEFDS_C_2_C500_STR-VL_FORN sy-vline
WA_J_1BEFDS_C_2_C500_STR-VL_SERV_NT sy-vline
WA_J_1BEFDS_C_2_C500_STR-VL_TERC sy-vline
WA_J_1BEFDS_C_2_C500_STR-VL_DA sy-vline
WA_J_1BEFDS_C_2_C500_STR-VL_BC_ICMS sy-vline
WA_J_1BEFDS_C_2_C500_STR-VL_ICMS sy-vline
WA_J_1BEFDS_C_2_C500_STR-VL_BC_ICMS_ST sy-vline
WA_J_1BEFDS_C_2_C500_STR-VL_ICMS_ST sy-vline
WA_J_1BEFDS_C_2_C500_STR-COD_INF sy-vline
WA_J_1BEFDS_C_2_C500_STR-VL_PIS sy-vline
WA_J_1BEFDS_C_2_C500_STR-VL_COFINS sy-vline
WA_J_1BEFDS_C_2_C500_STR-TP_CONNECTION sy-vline
WA_J_1BEFDS_C_2_C500_STR-COD_TENSION_GROUP sy-vline
WA_J_1BEFDS_C_2_C500_STR-TAB_C510 sy-vline
WA_J_1BEFDS_C_2_C500_STR-TAB_C590 sy-vline
WA_J_1BEFDS_C_2_C500_STR-TAB_CUST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.