ABAP Select data from SAP table J_1BNFE_ODATA_PRODVEIC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP J_1BNFE_ODATA_PRODVEIC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to J_1BNFE_ODATA_PRODVEIC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the J_1BNFE_ODATA_PRODVEIC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_J_1BNFE_ODATA_PRODVEIC TYPE STANDARD TABLE OF J_1BNFE_ODATA_PRODVEIC,
      WA_J_1BNFE_ODATA_PRODVEIC TYPE J_1BNFE_ODATA_PRODVEIC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <J_1BNFE_ODATA_PRODVEIC> TYPE J_1BNFE_ODATA_PRODVEIC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_J_1BNFE_ODATA_PRODVEIC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM J_1BNFE_ODATA_PRODVEIC
  INTO TABLE IT_J_1BNFE_ODATA_PRODVEIC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM J_1BNFE_ODATA_PRODVEIC
*  INTO TABLE @DATA(IT_J_1BNFE_ODATA_PRODVEIC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_J_1BNFE_ODATA_PRODVEIC INDEX 1 INTO DATA(WA_J_1BNFE_ODATA_PRODVEIC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_J_1BNFE_ODATA_PRODVEIC ASSIGNING <J_1BNFE_ODATA_PRODVEIC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<J_1BNFE_ODATA_PRODVEIC>-DOCNUM = 1.
<J_1BNFE_ODATA_PRODVEIC>-ITMNUM = 1.
<J_1BNFE_ODATA_PRODVEIC>-ID = 1.
<J_1BNFE_ODATA_PRODVEIC>-TP_OP = 1.
<J_1BNFE_ODATA_PRODVEIC>-CHASSI = 1.
ENDLOOP.

LOOP AT IT_J_1BNFE_ODATA_PRODVEIC INTO WA_J_1BNFE_ODATA_PRODVEIC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_J_1BNFE_ODATA_PRODVEIC-C_COR, sy-vline,
WA_J_1BNFE_ODATA_PRODVEIC-X_COR, sy-vline,
WA_J_1BNFE_ODATA_PRODVEIC-POT, sy-vline,
WA_J_1BNFE_ODATA_PRODVEIC-CILIN, sy-vline,
WA_J_1BNFE_ODATA_PRODVEIC-PESO_L, sy-vline,
WA_J_1BNFE_ODATA_PRODVEIC-PESO_B, sy-vline.
ENDLOOP. *Add any further fields from structure WA_J_1BNFE_ODATA_PRODVEIC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_J_1BNFE_ODATA_PRODVEIC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_J_1BNFE_ODATA_PRODVEIC INTO WA_J_1BNFE_ODATA_PRODVEIC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_J_1BNFE_ODATA_PRODVEIC_STR,
DOCNUM TYPE STRING,
ITMNUM TYPE STRING,
ID TYPE STRING,
TP_OP TYPE STRING,
CHASSI TYPE STRING,
C_COR TYPE STRING,
X_COR TYPE STRING,
POT TYPE STRING,
CILIN TYPE STRING,
PESO_L TYPE STRING,
PESO_B TYPE STRING,
N_SERIE TYPE STRING,
TP_COMB TYPE STRING,
N_MOTOR TYPE STRING,
CMT TYPE STRING,
DIST TYPE STRING,
ANO_MOD TYPE STRING,
ANO_FAB TYPE STRING,
TP_PINT TYPE STRING,
TP_VEIC TYPE STRING,
ESP_VEIC TYPE STRING,
VIN TYPE STRING,
COND_VEIC TYPE STRING,
C_MOD TYPE STRING,
C_COR_DENATRAN TYPE STRING,
LOTA TYPE STRING,
TP_REST TYPE STRING,END OF T_EKKO_STR. DATA: WA_J_1BNFE_ODATA_PRODVEIC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-DOCNUM sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-ITMNUM sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-ID sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-TP_OP sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-CHASSI sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-C_COR sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-X_COR sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-POT sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-CILIN sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-PESO_L sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-PESO_B sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-N_SERIE sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-TP_COMB sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-N_MOTOR sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-CMT sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-DIST sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-ANO_MOD sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-ANO_FAB sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-TP_PINT sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-TP_VEIC sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-ESP_VEIC sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-VIN sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-COND_VEIC sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-C_MOD sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-C_COR_DENATRAN sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-LOTA sy-vline
WA_J_1BNFE_ODATA_PRODVEIC_STR-TP_REST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.