ABAP Select data from SAP table LISCENSYS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LISCENSYS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LISCENSYS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LISCENSYS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LISCENSYS TYPE STANDARD TABLE OF LISCENSYS,
      WA_LISCENSYS TYPE LISCENSYS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LISCENSYS> TYPE LISCENSYS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LISCENSYS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LISCENSYS
  INTO TABLE IT_LISCENSYS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LISCENSYS
*  INTO TABLE @DATA(IT_LISCENSYS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LISCENSYS INDEX 1 INTO DATA(WA_LISCENSYS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LISCENSYS ASSIGNING <LISCENSYS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LISCENSYS>-DOMNAM = 1.
<LISCENSYS>-CENSYS = 1.
<LISCENSYS>-SAPCLIENT = 1.
<LISCENSYS>-TARSYS = 1.
<LISCENSYS>-STATUS = 1.
ENDLOOP.

LOOP AT IT_LISCENSYS INTO WA_LISCENSYS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LISCENSYS-TOPOLOGY, sy-vline,
WA_LISCENSYS-ALERT, sy-vline,
ENDLOOP. *Add any further fields from structure WA_LISCENSYS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LISCENSYS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LISCENSYS INTO WA_LISCENSYS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LISCENSYS_STR,
DOMNAM TYPE STRING,
CENSYS TYPE STRING,
SAPCLIENT TYPE STRING,
TARSYS TYPE STRING,
STATUS TYPE STRING,
TOPOLOGY TYPE STRING,
ALERT TYPE STRING,END OF T_EKKO_STR. DATA: WA_LISCENSYS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LISCENSYS_STR-DOMNAM sy-vline
WA_LISCENSYS_STR-CENSYS sy-vline
WA_LISCENSYS_STR-SAPCLIENT sy-vline
WA_LISCENSYS_STR-TARSYS sy-vline
WA_LISCENSYS_STR-STATUS sy-vline
WA_LISCENSYS_STR-TOPOLOGY sy-vline
WA_LISCENSYS_STR-ALERT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.