ABAP Select data from SAP table LTC_PROTEC_STMT2 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP LTC_PROTEC_STMT2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LTC_PROTEC_STMT2. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the LTC_PROTEC_STMT2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_LTC_PROTEC_STMT2 TYPE STANDARD TABLE OF LTC_PROTEC_STMT2, WA_LTC_PROTEC_STMT2 TYPE LTC_PROTEC_STMT2, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <LTC_PROTEC_STMT2> TYPE LTC_PROTEC_STMT2. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_LTC_PROTEC_STMT2. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM LTC_PROTEC_STMT2 INTO TABLE IT_LTC_PROTEC_STMT2. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM LTC_PROTEC_STMT2 * INTO TABLE @DATA(IT_LTC_PROTEC_STMT22). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_LTC_PROTEC_STMT2 INDEX 1 INTO DATA(WA_LTC_PROTEC_STMT22). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_LTC_PROTEC_STMT2 ASSIGNING <LTC_PROTEC_STMT2>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<LTC_PROTEC_STMT2>-CHILD_LATCH = 1.
<LTC_PROTEC_STMT2>-INST_ID = 1.
<LTC_PROTEC_STMT2>-ADDRESS = 1.
<LTC_PROTEC_STMT2>-HASH_VALUE = 1.
<LTC_PROTEC_STMT2>-USERNAME = 1.
ENDLOOP. LOOP AT IT_LTC_PROTEC_STMT2 INTO WA_LTC_PROTEC_STMT2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_LTC_PROTEC_STMT2-EXECUTIONS, sy-vline,
WA_LTC_PROTEC_STMT2-SQL_MODULE, sy-vline,
WA_LTC_PROTEC_STMT2-SQL_TEXT, sy-vline,
WA_LTC_PROTEC_STMT2-PARSE_CALLS, sy-vline,
WA_LTC_PROTEC_STMT2-PCALLS_PER_EXE, sy-vline,
WA_LTC_PROTEC_STMT2-PARSE_CALLS_PCT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LTC_PROTEC_STMT2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LTC_PROTEC_STMT2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LTC_PROTEC_STMT2 INTO WA_LTC_PROTEC_STMT2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LTC_PROTEC_STMT2_STR,
CHILD_LATCH TYPE STRING,
INST_ID TYPE STRING,
ADDRESS TYPE STRING,
HASH_VALUE TYPE STRING,
USERNAME TYPE STRING,
EXECUTIONS TYPE STRING,
SQL_MODULE TYPE STRING,
SQL_TEXT TYPE STRING,
PARSE_CALLS TYPE STRING,
PCALLS_PER_EXE TYPE STRING,
PARSE_CALLS_PCT TYPE STRING,
CPU_TIME TYPE STRING,
CPU_TIME_PER_EXE TYPE STRING,
CPU_TIME_PCT TYPE STRING,
ELAPSED_TIME TYPE STRING,
ELAPSED_TIME_PER_EXE TYPE STRING,
ELAPSED_TIME_PCT TYPE STRING,
DISK_READS TYPE STRING,
DISK_READS_PER_EXE TYPE STRING,
DISK_READS_PCT TYPE STRING,
BUFFER_GETS TYPE STRING,
BUFFER_GETS_PER_EXE TYPE STRING,
BUFFER_GETS_PCT TYPE STRING,
ROWS_PROCESSED TYPE STRING,
ROWS_PROCESSED_PER_EXE TYPE STRING,
ACTION TYPE STRING,END OF T_EKKO_STR. DATA: WA_LTC_PROTEC_STMT2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LTC_PROTEC_STMT2_STR-CHILD_LATCH sy-vline
WA_LTC_PROTEC_STMT2_STR-INST_ID sy-vline
WA_LTC_PROTEC_STMT2_STR-ADDRESS sy-vline
WA_LTC_PROTEC_STMT2_STR-HASH_VALUE sy-vline
WA_LTC_PROTEC_STMT2_STR-USERNAME sy-vline
WA_LTC_PROTEC_STMT2_STR-EXECUTIONS sy-vline
WA_LTC_PROTEC_STMT2_STR-SQL_MODULE sy-vline
WA_LTC_PROTEC_STMT2_STR-SQL_TEXT sy-vline
WA_LTC_PROTEC_STMT2_STR-PARSE_CALLS sy-vline
WA_LTC_PROTEC_STMT2_STR-PCALLS_PER_EXE sy-vline
WA_LTC_PROTEC_STMT2_STR-PARSE_CALLS_PCT sy-vline
WA_LTC_PROTEC_STMT2_STR-CPU_TIME sy-vline
WA_LTC_PROTEC_STMT2_STR-CPU_TIME_PER_EXE sy-vline
WA_LTC_PROTEC_STMT2_STR-CPU_TIME_PCT sy-vline
WA_LTC_PROTEC_STMT2_STR-ELAPSED_TIME sy-vline
WA_LTC_PROTEC_STMT2_STR-ELAPSED_TIME_PER_EXE sy-vline
WA_LTC_PROTEC_STMT2_STR-ELAPSED_TIME_PCT sy-vline
WA_LTC_PROTEC_STMT2_STR-DISK_READS sy-vline
WA_LTC_PROTEC_STMT2_STR-DISK_READS_PER_EXE sy-vline
WA_LTC_PROTEC_STMT2_STR-DISK_READS_PCT sy-vline
WA_LTC_PROTEC_STMT2_STR-BUFFER_GETS sy-vline
WA_LTC_PROTEC_STMT2_STR-BUFFER_GETS_PER_EXE sy-vline
WA_LTC_PROTEC_STMT2_STR-BUFFER_GETS_PCT sy-vline
WA_LTC_PROTEC_STMT2_STR-ROWS_PROCESSED sy-vline
WA_LTC_PROTEC_STMT2_STR-ROWS_PROCESSED_PER_EXE sy-vline
WA_LTC_PROTEC_STMT2_STR-ACTION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.