ABAP Select data from SAP table LTR2_UI_S_ES_TECHNICAL into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP LTR2_UI_S_ES_TECHNICAL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LTR2_UI_S_ES_TECHNICAL. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the LTR2_UI_S_ES_TECHNICAL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_LTR2_UI_S_ES_TECHNICAL TYPE STANDARD TABLE OF LTR2_UI_S_ES_TECHNICAL, WA_LTR2_UI_S_ES_TECHNICAL TYPE LTR2_UI_S_ES_TECHNICAL, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <LTR2_UI_S_ES_TECHNICAL> TYPE LTR2_UI_S_ES_TECHNICAL. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_LTR2_UI_S_ES_TECHNICAL. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM LTR2_UI_S_ES_TECHNICAL INTO TABLE IT_LTR2_UI_S_ES_TECHNICAL. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM LTR2_UI_S_ES_TECHNICAL * INTO TABLE @DATA(IT_LTR2_UI_S_ES_TECHNICAL2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_LTR2_UI_S_ES_TECHNICAL INDEX 1 INTO DATA(WA_LTR2_UI_S_ES_TECHNICAL2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_LTR2_UI_S_ES_TECHNICAL ASSIGNING <LTR2_UI_S_ES_TECHNICAL>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<LTR2_UI_S_ES_TECHNICAL>-TAB_ANR = 1.
<LTR2_UI_S_ES_TECHNICAL>-PE_PROJECT = 1.
<LTR2_UI_S_ES_TECHNICAL>-SHOW_PE = 1.
<LTR2_UI_S_ES_TECHNICAL>-NCE_PROJECT = 1.
<LTR2_UI_S_ES_TECHNICAL>-PACKID = 1.
ENDLOOP. LOOP AT IT_LTR2_UI_S_ES_TECHNICAL INTO WA_LTR2_UI_S_ES_TECHNICAL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_LTR2_UI_S_ES_TECHNICAL-WS_GUID, sy-vline,
WA_LTR2_UI_S_ES_TECHNICAL-MWB_PROJ, sy-vline,
WA_LTR2_UI_S_ES_TECHNICAL-MWB_SUBPROJ, sy-vline,
WA_LTR2_UI_S_ES_TECHNICAL-MWB_MTID, sy-vline,
WA_LTR2_UI_S_ES_TECHNICAL-SHOW_MWB, sy-vline,
WA_LTR2_UI_S_ES_TECHNICAL-REPL_MTID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LTR2_UI_S_ES_TECHNICAL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LTR2_UI_S_ES_TECHNICAL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LTR2_UI_S_ES_TECHNICAL INTO WA_LTR2_UI_S_ES_TECHNICAL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LTR2_UI_S_ES_TECHNICAL_STR,
TAB_ANR TYPE STRING,
PE_PROJECT TYPE STRING,
SHOW_PE TYPE STRING,
NCE_PROJECT TYPE STRING,
PACKID TYPE STRING,
WS_GUID TYPE STRING,
MWB_PROJ TYPE STRING,
MWB_SUBPROJ TYPE STRING,
MWB_MTID TYPE STRING,
SHOW_MWB TYPE STRING,
REPL_MTID TYPE STRING,
INCR_MTID TYPE STRING,
SLT_MTID TYPE STRING,
SHOW_IOBT TYPE STRING,
DESTCNT TYPE STRING,
STATUSCNT TYPE STRING,
SYSIDCNT TYPE STRING,
SHOWCNT TYPE STRING,
LASTCHECKEDCNT TYPE STRING,
LASTCHECKED_TEXTCNT TYPE STRING,
PACKIDCNT TYPE STRING,
EXEC_TARGETCNT TYPE STRING,
DESTCTR TYPE STRING,
STATUSCTR TYPE STRING,
SYSIDCTR TYPE STRING,
SHOWCTR TYPE STRING,
LASTCHECKEDCTR TYPE STRING,
LASTCHECKED_TEXTCTR TYPE STRING,
PACKIDCTR TYPE STRING,
EXEC_TARGETCTR TYPE STRING,
DESTSND TYPE STRING,
STATUSSND TYPE STRING,
SYSIDSND TYPE STRING,
SHOWSND TYPE STRING,
LASTCHECKEDSND TYPE STRING,
LASTCHECKED_TEXTSND TYPE STRING,
PACKIDSND TYPE STRING,
EXEC_TARGETSND TYPE STRING,
DESTRCV TYPE STRING,
STATUSRCV TYPE STRING,
SYSIDRCV TYPE STRING,
SHOWRCV TYPE STRING,
LASTCHECKEDRCV TYPE STRING,
LASTCHECKED_TEXTRCV TYPE STRING,
PACKIDRCV TYPE STRING,
EXEC_TARGETRCV TYPE STRING,
DESTEXE TYPE STRING,
STATUSEXE TYPE STRING,
SYSIDEXE TYPE STRING,
SHOWEXE TYPE STRING,
LASTCHECKEDEXE TYPE STRING,
LASTCHECKED_TEXTEXE TYPE STRING,
PACKIDEXE TYPE STRING,
EXEC_TARGETEXE TYPE STRING,
SHOW_PCL TYPE STRING,
SHOW_RFC TYPE STRING,
PCL_PROJECT TYPE STRING,
PCL_SUBPROJECT TYPE STRING,
SHOW_MEC TYPE STRING,
SHOW_KB TYPE STRING,
KB_PROJ_NAME_BUSINESS TYPE STRING,
KB_PROJ_NAME_TECHNICAL TYPE STRING,
SHOW_DEL_RCV TYPE STRING,
SHOW_CONV TYPE STRING,
DESTUPG TYPE STRING,
STATUSUPG TYPE STRING,
SYSIDUPG TYPE STRING,
SHOWUPG TYPE STRING,
LASTCHECKEDUPG TYPE STRING,
LASTCHECKED_TEXTUPG TYPE STRING,
PACKIDUPG TYPE STRING,
EXEC_TARGETUPG TYPE STRING,
RN_GUID TYPE STRING,END OF T_EKKO_STR. DATA: WA_LTR2_UI_S_ES_TECHNICAL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-TAB_ANR sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-PE_PROJECT sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SHOW_PE sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-NCE_PROJECT sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-PACKID sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-WS_GUID sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-MWB_PROJ sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-MWB_SUBPROJ sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-MWB_MTID sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SHOW_MWB sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-REPL_MTID sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-INCR_MTID sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SLT_MTID sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SHOW_IOBT sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-DESTCNT sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-STATUSCNT sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SYSIDCNT sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SHOWCNT sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-LASTCHECKEDCNT sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-LASTCHECKED_TEXTCNT sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-PACKIDCNT sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-EXEC_TARGETCNT sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-DESTCTR sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-STATUSCTR sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SYSIDCTR sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SHOWCTR sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-LASTCHECKEDCTR sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-LASTCHECKED_TEXTCTR sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-PACKIDCTR sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-EXEC_TARGETCTR sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-DESTSND sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-STATUSSND sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SYSIDSND sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SHOWSND sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-LASTCHECKEDSND sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-LASTCHECKED_TEXTSND sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-PACKIDSND sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-EXEC_TARGETSND sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-DESTRCV sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-STATUSRCV sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SYSIDRCV sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SHOWRCV sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-LASTCHECKEDRCV sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-LASTCHECKED_TEXTRCV sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-PACKIDRCV sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-EXEC_TARGETRCV sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-DESTEXE sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-STATUSEXE sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SYSIDEXE sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SHOWEXE sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-LASTCHECKEDEXE sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-LASTCHECKED_TEXTEXE sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-PACKIDEXE sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-EXEC_TARGETEXE sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SHOW_PCL sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SHOW_RFC sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-PCL_PROJECT sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-PCL_SUBPROJECT sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SHOW_MEC sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SHOW_KB sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-KB_PROJ_NAME_BUSINESS sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-KB_PROJ_NAME_TECHNICAL sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SHOW_DEL_RCV sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SHOW_CONV sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-DESTUPG sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-STATUSUPG sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SYSIDUPG sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-SHOWUPG sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-LASTCHECKEDUPG sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-LASTCHECKED_TEXTUPG sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-PACKIDUPG sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-EXEC_TARGETUPG sy-vline
WA_LTR2_UI_S_ES_TECHNICAL_STR-RN_GUID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.