ABAP Select data from SAP table LXWHS_V into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP LXWHS_V table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to LXWHS_V. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the LXWHS_V table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_LXWHS_V TYPE STANDARD TABLE OF LXWHS_V,
      WA_LXWHS_V TYPE LXWHS_V,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <LXWHS_V> TYPE LXWHS_V.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_LXWHS_V.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM LXWHS_V
  INTO TABLE IT_LXWHS_V.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM LXWHS_V
*  INTO TABLE @DATA(IT_LXWHS_V2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_LXWHS_V INDEX 1 INTO DATA(WA_LXWHS_V2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_LXWHS_V ASSIGNING <LXWHS_V>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<LXWHS_V>-MANDT = 1.
<LXWHS_V>-LGNUM = 1.
<LXWHS_V>-ONSTG = 1.
<LXWHS_V>-STTYP = 1.
<LXWHS_V>-OPPXD = 1.
ENDLOOP.

LOOP AT IT_LXWHS_V INTO WA_LXWHS_V.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_LXWHS_V-CNSFF, sy-vline,
WA_LXWHS_V-FFTOL, sy-vline,
WA_LXWHS_V-FFUOM, sy-vline,
WA_LXWHS_V-DTREF, sy-vline,
WA_LXWHS_V-TWMTC, sy-vline,
WA_LXWHS_V-ADREL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_LXWHS_V you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_LXWHS_V TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_LXWHS_V INTO WA_LXWHS_V. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field FFUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_LXWHS_V-FFUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LXWHS_V-FFUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WMUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_LXWHS_V-WMUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_LXWHS_V-WMUOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_LXWHS_V_STR,
MANDT TYPE STRING,
LGNUM TYPE STRING,
ONSTG TYPE STRING,
STTYP TYPE STRING,
OPPXD TYPE STRING,
CNSFF TYPE STRING,
FFTOL TYPE STRING,
FFUOM TYPE STRING,
DTREF TYPE STRING,
TWMTC TYPE STRING,
ADREL TYPE STRING,
ALREL TYPE STRING,
WMUOM TYPE STRING,END OF T_EKKO_STR. DATA: WA_LXWHS_V_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_LXWHS_V_STR-MANDT sy-vline
WA_LXWHS_V_STR-LGNUM sy-vline
WA_LXWHS_V_STR-ONSTG sy-vline
WA_LXWHS_V_STR-STTYP sy-vline
WA_LXWHS_V_STR-OPPXD sy-vline
WA_LXWHS_V_STR-CNSFF sy-vline
WA_LXWHS_V_STR-FFTOL sy-vline
WA_LXWHS_V_STR-FFUOM sy-vline
WA_LXWHS_V_STR-DTREF sy-vline
WA_LXWHS_V_STR-TWMTC sy-vline
WA_LXWHS_V_STR-ADREL sy-vline
WA_LXWHS_V_STR-ALREL sy-vline
WA_LXWHS_V_STR-WMUOM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.