ABAP Select data from SAP table MBEWU into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MBEWU table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MBEWU. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MBEWU table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MBEWU TYPE STANDARD TABLE OF MBEWU,
      WA_MBEWU TYPE MBEWU,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MBEWU> TYPE MBEWU.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MBEWU.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MBEWU
  INTO TABLE IT_MBEWU.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MBEWU
*  INTO TABLE @DATA(IT_MBEWU2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MBEWU INDEX 1 INTO DATA(WA_MBEWU2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MBEWU ASSIGNING <MBEWU>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MBEWU>-MANDT = 1.
<MBEWU>-MATNR = 1.
<MBEWU>-BWKEY = 1.
<MBEWU>-BWTAR = 1.
<MBEWU>-LVORM = 1.
ENDLOOP.

LOOP AT IT_MBEWU INTO WA_MBEWU.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MBEWU-VPRSV, sy-vline,
WA_MBEWU-STPRS, sy-vline,
WA_MBEWU-BKLAS, sy-vline,
WA_MBEWU-VMVPR, sy-vline,
WA_MBEWU-VMSTP, sy-vline,
WA_MBEWU-VMBKL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MBEWU you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MBEWU TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MBEWU INTO WA_MBEWU. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MBEWU-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MBEWU-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field PDATZ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_MBEWU-PDATZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MBEWU-PDATZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field PDATL CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_MBEWU-PDATL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MBEWU-PDATL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field PDATV CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_MBEWU-PDATV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MBEWU-PDATV.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MBEWU_STR,
MANDT TYPE STRING,
MATNR TYPE STRING,
BWKEY TYPE STRING,
BWTAR TYPE STRING,
LVORM TYPE STRING,
VPRSV TYPE STRING,
STPRS TYPE STRING,
BKLAS TYPE STRING,
VMVPR TYPE STRING,
VMSTP TYPE STRING,
VMBKL TYPE STRING,
VJVPR TYPE STRING,
VJSTP TYPE STRING,
VJBKL TYPE STRING,
BWTTY TYPE STRING,
TIMESTAMP TYPE STRING,
BWPRS TYPE STRING,
BWPRH TYPE STRING,
VJBWS TYPE STRING,
VJBWH TYPE STRING,
ZPLPR TYPE STRING,
ZPLP1 TYPE STRING,
ZPLP2 TYPE STRING,
ZPLP3 TYPE STRING,
ZPLD1 TYPE STRING,
ZPLD2 TYPE STRING,
ZPLD3 TYPE STRING,
PPERZ TYPE STRING,
PPERL TYPE STRING,
PPERV TYPE STRING,
KALKZ TYPE STRING,
KALKL TYPE STRING,
KALKV TYPE STRING,
KALSC TYPE STRING,
XLIFO TYPE STRING,
MYPOL TYPE STRING,
BWPH1 TYPE STRING,
BWPS1 TYPE STRING,
ABWKZ TYPE STRING,
PSTAT TYPE STRING,
KALN1 TYPE STRING,
KALNR TYPE STRING,
BWVA1 TYPE STRING,
BWVA2 TYPE STRING,
BWVA3 TYPE STRING,
VERS1 TYPE STRING,
VERS2 TYPE STRING,
VERS3 TYPE STRING,
HRKFT TYPE STRING,
KOSGR TYPE STRING,
PPRDZ TYPE STRING,
PPRDL TYPE STRING,
PPRDV TYPE STRING,
PDATZ TYPE STRING,
PDATL TYPE STRING,
PDATV TYPE STRING,
EKALR TYPE STRING,
VPLPR TYPE STRING,
MLMAA TYPE STRING,
MLAST TYPE STRING,
LPLPR TYPE STRING,
HKMAT TYPE STRING,
SPERW TYPE STRING,
KZIWL TYPE STRING,
WLINL TYPE STRING,
ABCIW TYPE STRING,
BWSPA TYPE STRING,
LPLPX TYPE STRING,
VPLPX TYPE STRING,
FPLPX TYPE STRING,
LBWST TYPE STRING,
VBWST TYPE STRING,
FBWST TYPE STRING,
EKLAS TYPE STRING,
QKLAS TYPE STRING,
MTUSE TYPE STRING,
MTORG TYPE STRING,
OWNPR TYPE STRING,
XBEWM TYPE STRING,
BWPEI TYPE STRING,
OKLAS TYPE STRING,
DUMMY_VAL_INCL_EEW_PS TYPE STRING,
OIPPINV TYPE STRING,END OF T_EKKO_STR. DATA: WA_MBEWU_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MBEWU_STR-MANDT sy-vline
WA_MBEWU_STR-MATNR sy-vline
WA_MBEWU_STR-BWKEY sy-vline
WA_MBEWU_STR-BWTAR sy-vline
WA_MBEWU_STR-LVORM sy-vline
WA_MBEWU_STR-VPRSV sy-vline
WA_MBEWU_STR-STPRS sy-vline
WA_MBEWU_STR-BKLAS sy-vline
WA_MBEWU_STR-VMVPR sy-vline
WA_MBEWU_STR-VMSTP sy-vline
WA_MBEWU_STR-VMBKL sy-vline
WA_MBEWU_STR-VJVPR sy-vline
WA_MBEWU_STR-VJSTP sy-vline
WA_MBEWU_STR-VJBKL sy-vline
WA_MBEWU_STR-BWTTY sy-vline
WA_MBEWU_STR-TIMESTAMP sy-vline
WA_MBEWU_STR-BWPRS sy-vline
WA_MBEWU_STR-BWPRH sy-vline
WA_MBEWU_STR-VJBWS sy-vline
WA_MBEWU_STR-VJBWH sy-vline
WA_MBEWU_STR-ZPLPR sy-vline
WA_MBEWU_STR-ZPLP1 sy-vline
WA_MBEWU_STR-ZPLP2 sy-vline
WA_MBEWU_STR-ZPLP3 sy-vline
WA_MBEWU_STR-ZPLD1 sy-vline
WA_MBEWU_STR-ZPLD2 sy-vline
WA_MBEWU_STR-ZPLD3 sy-vline
WA_MBEWU_STR-PPERZ sy-vline
WA_MBEWU_STR-PPERL sy-vline
WA_MBEWU_STR-PPERV sy-vline
WA_MBEWU_STR-KALKZ sy-vline
WA_MBEWU_STR-KALKL sy-vline
WA_MBEWU_STR-KALKV sy-vline
WA_MBEWU_STR-KALSC sy-vline
WA_MBEWU_STR-XLIFO sy-vline
WA_MBEWU_STR-MYPOL sy-vline
WA_MBEWU_STR-BWPH1 sy-vline
WA_MBEWU_STR-BWPS1 sy-vline
WA_MBEWU_STR-ABWKZ sy-vline
WA_MBEWU_STR-PSTAT sy-vline
WA_MBEWU_STR-KALN1 sy-vline
WA_MBEWU_STR-KALNR sy-vline
WA_MBEWU_STR-BWVA1 sy-vline
WA_MBEWU_STR-BWVA2 sy-vline
WA_MBEWU_STR-BWVA3 sy-vline
WA_MBEWU_STR-VERS1 sy-vline
WA_MBEWU_STR-VERS2 sy-vline
WA_MBEWU_STR-VERS3 sy-vline
WA_MBEWU_STR-HRKFT sy-vline
WA_MBEWU_STR-KOSGR sy-vline
WA_MBEWU_STR-PPRDZ sy-vline
WA_MBEWU_STR-PPRDL sy-vline
WA_MBEWU_STR-PPRDV sy-vline
WA_MBEWU_STR-PDATZ sy-vline
WA_MBEWU_STR-PDATL sy-vline
WA_MBEWU_STR-PDATV sy-vline
WA_MBEWU_STR-EKALR sy-vline
WA_MBEWU_STR-VPLPR sy-vline
WA_MBEWU_STR-MLMAA sy-vline
WA_MBEWU_STR-MLAST sy-vline
WA_MBEWU_STR-LPLPR sy-vline
WA_MBEWU_STR-HKMAT sy-vline
WA_MBEWU_STR-SPERW sy-vline
WA_MBEWU_STR-KZIWL sy-vline
WA_MBEWU_STR-WLINL sy-vline
WA_MBEWU_STR-ABCIW sy-vline
WA_MBEWU_STR-BWSPA sy-vline
WA_MBEWU_STR-LPLPX sy-vline
WA_MBEWU_STR-VPLPX sy-vline
WA_MBEWU_STR-FPLPX sy-vline
WA_MBEWU_STR-LBWST sy-vline
WA_MBEWU_STR-VBWST sy-vline
WA_MBEWU_STR-FBWST sy-vline
WA_MBEWU_STR-EKLAS sy-vline
WA_MBEWU_STR-QKLAS sy-vline
WA_MBEWU_STR-MTUSE sy-vline
WA_MBEWU_STR-MTORG sy-vline
WA_MBEWU_STR-OWNPR sy-vline
WA_MBEWU_STR-XBEWM sy-vline
WA_MBEWU_STR-BWPEI sy-vline
WA_MBEWU_STR-OKLAS sy-vline
WA_MBEWU_STR-DUMMY_VAL_INCL_EEW_PS sy-vline
WA_MBEWU_STR-OIPPINV sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.