ABAP Select data from SAP table MC05QV2UDN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MC05QV2UDN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MC05QV2UDN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MC05QV2UDN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MC05QV2UDN TYPE STANDARD TABLE OF MC05QV2UDN,
      WA_MC05QV2UDN TYPE MC05QV2UDN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MC05QV2UDN> TYPE MC05QV2UDN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MC05QV2UDN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MC05QV2UDN
  INTO TABLE IT_MC05QV2UDN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MC05QV2UDN
*  INTO TABLE @DATA(IT_MC05QV2UDN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MC05QV2UDN INDEX 1 INTO DATA(WA_MC05QV2UDN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MC05QV2UDN ASSIGNING <MC05QV2UDN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MC05QV2UDN>-ANTEIL = 1.
<MC05QV2UDN>-DURATION_INT = 1.
<MC05QV2UDN>-EINHPROBE = 1.
<MC05QV2UDN>-EINHTAG = 1.
<MC05QV2UDN>-LMENGEPR = 1.
ENDLOOP.

LOOP AT IT_MC05QV2UDN INTO WA_MC05QV2UDN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MC05QV2UDN-QKENNZAHL, sy-vline,
WA_MC05QV2UDN-QTYQAVE_ACC, sy-vline,
WA_MC05QV2UDN-QTYQAVE_REJ, sy-vline,
WA_MC05QV2UDN-VCODE, sy-vline,
WA_MC05QV2UDN-VCODEGRP, sy-vline,
WA_MC05QV2UDN-VKATART, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MC05QV2UDN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MC05QV2UDN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MC05QV2UDN INTO WA_MC05QV2UDN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field EINHPROBE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC05QV2UDN-EINHPROBE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC05QV2UDN-EINHPROBE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EINHTAG CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC05QV2UDN-EINHTAG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC05QV2UDN-EINHTAG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MC05QV2UDN_STR,
ANTEIL TYPE STRING,
DURATION_INT TYPE STRING,
EINHPROBE TYPE STRING,
EINHTAG TYPE STRING,
LMENGEPR TYPE STRING,
QKENNZAHL TYPE STRING,
QTYQAVE_ACC TYPE STRING,
QTYQAVE_REJ TYPE STRING,
VCODE TYPE STRING,
VCODEGRP TYPE STRING,
VKATART TYPE STRING,
ZHLQAVE_ACC TYPE STRING,
ZHLQAVE_REJ TYPE STRING,END OF T_EKKO_STR. DATA: WA_MC05QV2UDN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MC05QV2UDN_STR-ANTEIL sy-vline
WA_MC05QV2UDN_STR-DURATION_INT sy-vline
WA_MC05QV2UDN_STR-EINHPROBE sy-vline
WA_MC05QV2UDN_STR-EINHTAG sy-vline
WA_MC05QV2UDN_STR-LMENGEPR sy-vline
WA_MC05QV2UDN_STR-QKENNZAHL sy-vline
WA_MC05QV2UDN_STR-QTYQAVE_ACC sy-vline
WA_MC05QV2UDN_STR-QTYQAVE_REJ sy-vline
WA_MC05QV2UDN_STR-VCODE sy-vline
WA_MC05QV2UDN_STR-VCODEGRP sy-vline
WA_MC05QV2UDN_STR-VKATART sy-vline
WA_MC05QV2UDN_STR-ZHLQAVE_ACC sy-vline
WA_MC05QV2UDN_STR-ZHLQAVE_REJ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.