ABAP Select data from SAP table MC11V_0SSL into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP MC11V_0SSL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MC11V_0SSL. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the MC11V_0SSL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_MC11V_0SSL TYPE STANDARD TABLE OF MC11V_0SSL, WA_MC11V_0SSL TYPE MC11V_0SSL, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <MC11V_0SSL> TYPE MC11V_0SSL. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_MC11V_0SSL. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM MC11V_0SSL INTO TABLE IT_MC11V_0SSL. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM MC11V_0SSL * INTO TABLE @DATA(IT_MC11V_0SSL2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_MC11V_0SSL INDEX 1 INTO DATA(WA_MC11V_0SSL2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_MC11V_0SSL ASSIGNING <MC11V_0SSL>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<MC11V_0SSL>-VBELN = 1.
<MC11V_0SSL>-POSNR = 1.
<MC11V_0SSL>-ETENR = 1.
<MC11V_0SSL>-VBELN_VL = 1.
<MC11V_0SSL>-POSNR_VL = 1.
ENDLOOP. LOOP AT IT_MC11V_0SSL INTO WA_MC11V_0SSL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_MC11V_0SSL-ROCANCEL, sy-vline,
WA_MC11V_0SSL-WMENG, sy-vline,
WA_MC11V_0SSL-BMENG, sy-vline,
WA_MC11V_0SSL-VSMNG, sy-vline,
WA_MC11V_0SSL-VRKME, sy-vline,
WA_MC11V_0SSL-LFGSA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MC11V_0SSL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MC11V_0SSL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MC11V_0SSL INTO WA_MC11V_0SSL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC11V_0SSL-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11V_0SSL-VBELN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VBELN_VL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MC11V_0SSL-VBELN_VL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11V_0SSL-VBELN_VL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field VRKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC11V_0SSL-VRKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11V_0SSL-VRKME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MC11V_0SSL-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MC11V_0SSL-MEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MC11V_0SSL_STR,
VBELN TYPE STRING,
POSNR TYPE STRING,
ETENR TYPE STRING,
VBELN_VL TYPE STRING,
POSNR_VL TYPE STRING,
ROCANCEL TYPE STRING,
WMENG TYPE STRING,
BMENG TYPE STRING,
VSMNG TYPE STRING,
VRKME TYPE STRING,
LFGSA TYPE STRING,
LFSTA TYPE STRING,
WBSTA TYPE STRING,
MCEX_WBSTA_LOW TYPE STRING,
MCEX_W_LFDAT TYPE STRING,
MCEX_W_LFUHR TYPE STRING,
MCEX_B_LFDAT TYPE STRING,
MCEX_B_LFUHR TYPE STRING,
MCEX_B_WADAT TYPE STRING,
MCEX_I_WADAT TYPE STRING,
MCEX_I_WADATLATE TYPE STRING,
MCEX_I_LFDAT TYPE STRING,
MCEX_I_LFUHR TYPE STRING,
MCEX_I_LFDATLATE TYPE STRING,
MCEX_I_LFUHRLATE TYPE STRING,
LIFSP TYPE STRING,
MEINS TYPE STRING,
UMVKN TYPE STRING,
UMVKZ TYPE STRING,
VBTYP TYPE STRING,
VBEP_DELETED TYPE STRING,
RECORD_DELETED TYPE STRING,END OF T_EKKO_STR. DATA: WA_MC11V_0SSL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MC11V_0SSL_STR-VBELN sy-vline
WA_MC11V_0SSL_STR-POSNR sy-vline
WA_MC11V_0SSL_STR-ETENR sy-vline
WA_MC11V_0SSL_STR-VBELN_VL sy-vline
WA_MC11V_0SSL_STR-POSNR_VL sy-vline
WA_MC11V_0SSL_STR-ROCANCEL sy-vline
WA_MC11V_0SSL_STR-WMENG sy-vline
WA_MC11V_0SSL_STR-BMENG sy-vline
WA_MC11V_0SSL_STR-VSMNG sy-vline
WA_MC11V_0SSL_STR-VRKME sy-vline
WA_MC11V_0SSL_STR-LFGSA sy-vline
WA_MC11V_0SSL_STR-LFSTA sy-vline
WA_MC11V_0SSL_STR-WBSTA sy-vline
WA_MC11V_0SSL_STR-MCEX_WBSTA_LOW sy-vline
WA_MC11V_0SSL_STR-MCEX_W_LFDAT sy-vline
WA_MC11V_0SSL_STR-MCEX_W_LFUHR sy-vline
WA_MC11V_0SSL_STR-MCEX_B_LFDAT sy-vline
WA_MC11V_0SSL_STR-MCEX_B_LFUHR sy-vline
WA_MC11V_0SSL_STR-MCEX_B_WADAT sy-vline
WA_MC11V_0SSL_STR-MCEX_I_WADAT sy-vline
WA_MC11V_0SSL_STR-MCEX_I_WADATLATE sy-vline
WA_MC11V_0SSL_STR-MCEX_I_LFDAT sy-vline
WA_MC11V_0SSL_STR-MCEX_I_LFUHR sy-vline
WA_MC11V_0SSL_STR-MCEX_I_LFDATLATE sy-vline
WA_MC11V_0SSL_STR-MCEX_I_LFUHRLATE sy-vline
WA_MC11V_0SSL_STR-LIFSP sy-vline
WA_MC11V_0SSL_STR-MEINS sy-vline
WA_MC11V_0SSL_STR-UMVKN sy-vline
WA_MC11V_0SSL_STR-UMVKZ sy-vline
WA_MC11V_0SSL_STR-VBTYP sy-vline
WA_MC11V_0SSL_STR-VBEP_DELETED sy-vline
WA_MC11V_0SSL_STR-RECORD_DELETED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.