ABAP Select data from SAP table MDG_GN_TECH_SETTINGS into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP MDG_GN_TECH_SETTINGS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MDG_GN_TECH_SETTINGS. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the MDG_GN_TECH_SETTINGS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_MDG_GN_TECH_SETTINGS TYPE STANDARD TABLE OF MDG_GN_TECH_SETTINGS, WA_MDG_GN_TECH_SETTINGS TYPE MDG_GN_TECH_SETTINGS, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <MDG_GN_TECH_SETTINGS> TYPE MDG_GN_TECH_SETTINGS. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_MDG_GN_TECH_SETTINGS. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM MDG_GN_TECH_SETTINGS INTO TABLE IT_MDG_GN_TECH_SETTINGS. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM MDG_GN_TECH_SETTINGS * INTO TABLE @DATA(IT_MDG_GN_TECH_SETTINGS2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_MDG_GN_TECH_SETTINGS INDEX 1 INTO DATA(WA_MDG_GN_TECH_SETTINGS2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_MDG_GN_TECH_SETTINGS ASSIGNING <MDG_GN_TECH_SETTINGS>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<MDG_GN_TECH_SETTINGS>-SIZE_CAT = 1.
<MDG_GN_TECH_SETTINGS>-DATA_CLASS = 1.
<MDG_GN_TECH_SETTINGS>-BUFFERING = 1.
<MDG_GN_TECH_SETTINGS>-BUF_KIND = 1.
<MDG_GN_TECH_SETTINGS>-KEY_FIELD_NO = 1.
ENDLOOP. LOOP AT IT_MDG_GN_TECH_SETTINGS INTO WA_MDG_GN_TECH_SETTINGS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_MDG_GN_TECH_SETTINGS-PROTOKOLL, sy-vline,
WA_MDG_GN_TECH_SETTINGS-TRANS_CLASS, sy-vline,
WA_MDG_GN_TECH_SETTINGS-MAINTAIN, sy-vline,
ENDLOOP. *Add any further fields from structure WA_MDG_GN_TECH_SETTINGS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MDG_GN_TECH_SETTINGS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MDG_GN_TECH_SETTINGS INTO WA_MDG_GN_TECH_SETTINGS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MDG_GN_TECH_SETTINGS_STR,
SIZE_CAT TYPE STRING,
DATA_CLASS TYPE STRING,
BUFFERING TYPE STRING,
BUF_KIND TYPE STRING,
KEY_FIELD_NO TYPE STRING,
PROTOKOLL TYPE STRING,
TRANS_CLASS TYPE STRING,
MAINTAIN TYPE STRING,END OF T_EKKO_STR. DATA: WA_MDG_GN_TECH_SETTINGS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MDG_GN_TECH_SETTINGS_STR-SIZE_CAT sy-vline
WA_MDG_GN_TECH_SETTINGS_STR-DATA_CLASS sy-vline
WA_MDG_GN_TECH_SETTINGS_STR-BUFFERING sy-vline
WA_MDG_GN_TECH_SETTINGS_STR-BUF_KIND sy-vline
WA_MDG_GN_TECH_SETTINGS_STR-KEY_FIELD_NO sy-vline
WA_MDG_GN_TECH_SETTINGS_STR-PROTOKOLL sy-vline
WA_MDG_GN_TECH_SETTINGS_STR-TRANS_CLASS sy-vline
WA_MDG_GN_TECH_SETTINGS_STR-MAINTAIN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.