ABAP Select data from SAP table MPE_RTGV_ORD_CMP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPE_RTGV_ORD_CMP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPE_RTGV_ORD_CMP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the MPE_RTGV_ORD_CMP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_MPE_RTGV_ORD_CMP TYPE STANDARD TABLE OF MPE_RTGV_ORD_CMP, WA_MPE_RTGV_ORD_CMP TYPE MPE_RTGV_ORD_CMP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <MPE_RTGV_ORD_CMP> TYPE MPE_RTGV_ORD_CMP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_MPE_RTGV_ORD_CMP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM MPE_RTGV_ORD_CMP INTO TABLE IT_MPE_RTGV_ORD_CMP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM MPE_RTGV_ORD_CMP * INTO TABLE @DATA(IT_MPE_RTGV_ORD_CMP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_MPE_RTGV_ORD_CMP INDEX 1 INTO DATA(WA_MPE_RTGV_ORD_CMP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_MPE_RTGV_ORD_CMP ASSIGNING <MPE_RTGV_ORD_CMP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPE_RTGV_ORD_CMP>-MANDT = 1.
<MPE_RTGV_ORD_CMP>-PLNTY = 1.
<MPE_RTGV_ORD_CMP>-PLNNR = 1.
<MPE_RTGV_ORD_CMP>-PLNAL = 1.
<MPE_RTGV_ORD_CMP>-VERSN = 1.
ENDLOOP. LOOP AT IT_MPE_RTGV_ORD_CMP INTO WA_MPE_RTGV_ORD_CMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_MPE_RTGV_ORD_CMP-DELTA_CMP_CNT, sy-vline,
WA_MPE_RTGV_ORD_CMP-DELTA_TYPE, sy-vline,
WA_MPE_RTGV_ORD_CMP-AUFNR, sy-vline,
WA_MPE_RTGV_ORD_CMP-STLAN, sy-vline,
WA_MPE_RTGV_ORD_CMP-WERKS, sy-vline,
WA_MPE_RTGV_ORD_CMP-MATNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPE_RTGV_ORD_CMP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPE_RTGV_ORD_CMP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPE_RTGV_ORD_CMP INTO WA_MPE_RTGV_ORD_CMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPE_RTGV_ORD_CMP-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPE_RTGV_ORD_CMP-PLNNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPE_RTGV_ORD_CMP-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPE_RTGV_ORD_CMP-PLNAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPE_RTGV_ORD_CMP-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPE_RTGV_ORD_CMP-VERSN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPE_RTGV_ORD_CMP-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPE_RTGV_ORD_CMP-AUFNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPE_RTGV_ORD_CMP-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPE_RTGV_ORD_CMP-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPE_RTGV_ORD_CMP-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPE_RTGV_ORD_CMP-STLNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPE_RTGV_ORD_CMP-STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPE_RTGV_ORD_CMP-STLAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field IDNRK CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPE_RTGV_ORD_CMP-IDNRK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPE_RTGV_ORD_CMP-IDNRK.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field POSNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPE_RTGV_ORD_CMP-POSNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPE_RTGV_ORD_CMP-POSNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPE_RTGV_ORD_CMP-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPE_RTGV_ORD_CMP-MEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPE_RTGV_ORD_CMP_STR,
MANDT TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
VERSN TYPE STRING,
DELTA_CMP_CNT TYPE STRING,
DELTA_TYPE TYPE STRING,
AUFNR TYPE STRING,
STLAN TYPE STRING,
WERKS TYPE STRING,
MATNR TYPE STRING,
STLTY TYPE STRING,
STLNR TYPE STRING,
STLAL TYPE STRING,
BOM_VERSN TYPE STRING,
STLKN TYPE STRING,
STVKN TYPE STRING,
STVKN_VERSN TYPE STRING,
STLKN_REFERENCE TYPE STRING,
INSMK TYPE STRING,
ASSEMBLY_TYPE TYPE STRING,
OAN_ELEMENT_NUMBER TYPE STRING,
IDNRK TYPE STRING,
PSWRK TYPE STRING,
POSTP TYPE STRING,
POSNR TYPE STRING,
MATKL TYPE STRING,
MEINS TYPE STRING,
MENGE TYPE STRING,
FMENG TYPE STRING,
AUSCH TYPE STRING,
AVOAU TYPE STRING,
NETAU TYPE STRING,
SCHGT TYPE STRING,
LGORT TYPE STRING,
ITSOB TYPE STRING,
PRVBE TYPE STRING,
POTX1 TYPE STRING,
POTX2 TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_AT TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_AT TYPE STRING,
DUMMY_STPO_INCL_EEW_PS TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPE_RTGV_ORD_CMP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPE_RTGV_ORD_CMP_STR-MANDT sy-vline
WA_MPE_RTGV_ORD_CMP_STR-PLNTY sy-vline
WA_MPE_RTGV_ORD_CMP_STR-PLNNR sy-vline
WA_MPE_RTGV_ORD_CMP_STR-PLNAL sy-vline
WA_MPE_RTGV_ORD_CMP_STR-VERSN sy-vline
WA_MPE_RTGV_ORD_CMP_STR-DELTA_CMP_CNT sy-vline
WA_MPE_RTGV_ORD_CMP_STR-DELTA_TYPE sy-vline
WA_MPE_RTGV_ORD_CMP_STR-AUFNR sy-vline
WA_MPE_RTGV_ORD_CMP_STR-STLAN sy-vline
WA_MPE_RTGV_ORD_CMP_STR-WERKS sy-vline
WA_MPE_RTGV_ORD_CMP_STR-MATNR sy-vline
WA_MPE_RTGV_ORD_CMP_STR-STLTY sy-vline
WA_MPE_RTGV_ORD_CMP_STR-STLNR sy-vline
WA_MPE_RTGV_ORD_CMP_STR-STLAL sy-vline
WA_MPE_RTGV_ORD_CMP_STR-BOM_VERSN sy-vline
WA_MPE_RTGV_ORD_CMP_STR-STLKN sy-vline
WA_MPE_RTGV_ORD_CMP_STR-STVKN sy-vline
WA_MPE_RTGV_ORD_CMP_STR-STVKN_VERSN sy-vline
WA_MPE_RTGV_ORD_CMP_STR-STLKN_REFERENCE sy-vline
WA_MPE_RTGV_ORD_CMP_STR-INSMK sy-vline
WA_MPE_RTGV_ORD_CMP_STR-ASSEMBLY_TYPE sy-vline
WA_MPE_RTGV_ORD_CMP_STR-OAN_ELEMENT_NUMBER sy-vline
WA_MPE_RTGV_ORD_CMP_STR-IDNRK sy-vline
WA_MPE_RTGV_ORD_CMP_STR-PSWRK sy-vline
WA_MPE_RTGV_ORD_CMP_STR-POSTP sy-vline
WA_MPE_RTGV_ORD_CMP_STR-POSNR sy-vline
WA_MPE_RTGV_ORD_CMP_STR-MATKL sy-vline
WA_MPE_RTGV_ORD_CMP_STR-MEINS sy-vline
WA_MPE_RTGV_ORD_CMP_STR-MENGE sy-vline
WA_MPE_RTGV_ORD_CMP_STR-FMENG sy-vline
WA_MPE_RTGV_ORD_CMP_STR-AUSCH sy-vline
WA_MPE_RTGV_ORD_CMP_STR-AVOAU sy-vline
WA_MPE_RTGV_ORD_CMP_STR-NETAU sy-vline
WA_MPE_RTGV_ORD_CMP_STR-SCHGT sy-vline
WA_MPE_RTGV_ORD_CMP_STR-LGORT sy-vline
WA_MPE_RTGV_ORD_CMP_STR-ITSOB sy-vline
WA_MPE_RTGV_ORD_CMP_STR-PRVBE sy-vline
WA_MPE_RTGV_ORD_CMP_STR-POTX1 sy-vline
WA_MPE_RTGV_ORD_CMP_STR-POTX2 sy-vline
WA_MPE_RTGV_ORD_CMP_STR-CREATED_BY sy-vline
WA_MPE_RTGV_ORD_CMP_STR-CREATED_AT sy-vline
WA_MPE_RTGV_ORD_CMP_STR-CHANGED_BY sy-vline
WA_MPE_RTGV_ORD_CMP_STR-CHANGED_AT sy-vline
WA_MPE_RTGV_ORD_CMP_STR-DUMMY_STPO_INCL_EEW_PS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.