ABAP Select data from SAP table MPES_BOM_PS_REL_UPD into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPES_BOM_PS_REL_UPD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPES_BOM_PS_REL_UPD. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the MPES_BOM_PS_REL_UPD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_MPES_BOM_PS_REL_UPD TYPE STANDARD TABLE OF MPES_BOM_PS_REL_UPD, WA_MPES_BOM_PS_REL_UPD TYPE MPES_BOM_PS_REL_UPD, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <MPES_BOM_PS_REL_UPD> TYPE MPES_BOM_PS_REL_UPD. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_MPES_BOM_PS_REL_UPD. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM MPES_BOM_PS_REL_UPD INTO TABLE IT_MPES_BOM_PS_REL_UPD. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM MPES_BOM_PS_REL_UPD * INTO TABLE @DATA(IT_MPES_BOM_PS_REL_UPD2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_MPES_BOM_PS_REL_UPD INDEX 1 INTO DATA(WA_MPES_BOM_PS_REL_UPD2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_MPES_BOM_PS_REL_UPD ASSIGNING <MPES_BOM_PS_REL_UPD>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPES_BOM_PS_REL_UPD>-MANDT = 1.
<MPES_BOM_PS_REL_UPD>-SFI_ID = 1.
<MPES_BOM_PS_REL_UPD>-MATNR = 1.
<MPES_BOM_PS_REL_UPD>-WERKS = 1.
<MPES_BOM_PS_REL_UPD>-STLNR = 1.
ENDLOOP. LOOP AT IT_MPES_BOM_PS_REL_UPD INTO WA_MPES_BOM_PS_REL_UPD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_MPES_BOM_PS_REL_UPD-STLAL, sy-vline,
WA_MPES_BOM_PS_REL_UPD-STLAN, sy-vline,
WA_MPES_BOM_PS_REL_UPD-BOM_VERSN, sy-vline,
WA_MPES_BOM_PS_REL_UPD-CRTN_TIME, sy-vline,
WA_MPES_BOM_PS_REL_UPD-TECHS, sy-vline,
WA_MPES_BOM_PS_REL_UPD-AUFNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPES_BOM_PS_REL_UPD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPES_BOM_PS_REL_UPD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPES_BOM_PS_REL_UPD INTO WA_MPES_BOM_PS_REL_UPD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_BOM_PS_REL_UPD-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_BOM_PS_REL_UPD-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_BOM_PS_REL_UPD-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_BOM_PS_REL_UPD-STLNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_BOM_PS_REL_UPD-STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_BOM_PS_REL_UPD-STLAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_BOM_PS_REL_UPD-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_BOM_PS_REL_UPD-AUFNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field PARENT_MA CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_BOM_PS_REL_UPD-PARENT_MA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_BOM_PS_REL_UPD-PARENT_MA.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ABPSN, internal->external for field PROJECT_ID CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_MPES_BOM_PS_REL_UPD-PROJECT_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_BOM_PS_REL_UPD-PROJECT_ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field PARENT_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_BOM_PS_REL_UPD-PARENT_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_BOM_PS_REL_UPD-PARENT_MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field PARENT_STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_BOM_PS_REL_UPD-PARENT_STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_BOM_PS_REL_UPD-PARENT_STLNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PARENT_STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_BOM_PS_REL_UPD-PARENT_STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_BOM_PS_REL_UPD-PARENT_STLAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPES_BOM_PS_REL_UPD_STR,
MANDT TYPE STRING,
SFI_ID TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
STLNR TYPE STRING,
STLAL TYPE STRING,
STLAN TYPE STRING,
BOM_VERSN TYPE STRING,
CRTN_TIME TYPE STRING,
TECHS TYPE STRING,
AUFNR TYPE STRING,
PARENT_MA TYPE STRING,
VERSION_SELECTION TYPE STRING,
PROJECT_ID TYPE STRING,
PARENT_SFI_ID TYPE STRING,
EXPLOSION_DATE TYPE STRING,
PARENT_MATNR TYPE STRING,
PARENT_STLNR TYPE STRING,
PARENT_STLAL TYPE STRING,
PARENT_STLAN TYPE STRING,
PARENT_BOM_VERSN TYPE STRING,
PARENT_STLKN TYPE STRING,
PARENT_STVKN TYPE STRING,
PARENT_AUFPL TYPE STRING,
PARENT_APLZL TYPE STRING,
ISMANETWORK TYPE STRING,
PROJASSIGN TYPE STRING,
VBUKZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPES_BOM_PS_REL_UPD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-MANDT sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-SFI_ID sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-MATNR sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-WERKS sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-STLNR sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-STLAL sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-STLAN sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-BOM_VERSN sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-CRTN_TIME sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-TECHS sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-AUFNR sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-PARENT_MA sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-VERSION_SELECTION sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-PROJECT_ID sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-PARENT_SFI_ID sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-EXPLOSION_DATE sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-PARENT_MATNR sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-PARENT_STLNR sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-PARENT_STLAL sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-PARENT_STLAN sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-PARENT_BOM_VERSN sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-PARENT_STLKN sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-PARENT_STVKN sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-PARENT_AUFPL sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-PARENT_APLZL sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-ISMANETWORK sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-PROJASSIGN sy-vline
WA_MPES_BOM_PS_REL_UPD_STR-VBUKZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.