ABAP Select data from SAP table MPES_MAPROJ_BOMNC_RESULT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPES_MAPROJ_BOMNC_RESULT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPES_MAPROJ_BOMNC_RESULT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MPES_MAPROJ_BOMNC_RESULT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MPES_MAPROJ_BOMNC_RESULT TYPE STANDARD TABLE OF MPES_MAPROJ_BOMNC_RESULT,
      WA_MPES_MAPROJ_BOMNC_RESULT TYPE MPES_MAPROJ_BOMNC_RESULT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MPES_MAPROJ_BOMNC_RESULT> TYPE MPES_MAPROJ_BOMNC_RESULT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MPES_MAPROJ_BOMNC_RESULT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MPES_MAPROJ_BOMNC_RESULT
  INTO TABLE IT_MPES_MAPROJ_BOMNC_RESULT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MPES_MAPROJ_BOMNC_RESULT
*  INTO TABLE @DATA(IT_MPES_MAPROJ_BOMNC_RESULT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MPES_MAPROJ_BOMNC_RESULT INDEX 1 INTO DATA(WA_MPES_MAPROJ_BOMNC_RESULT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MPES_MAPROJ_BOMNC_RESULT ASSIGNING <MPES_MAPROJ_BOMNC_RESULT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPES_MAPROJ_BOMNC_RESULT>-MATNR = 1.
<MPES_MAPROJ_BOMNC_RESULT>-WERKS = 1.
<MPES_MAPROJ_BOMNC_RESULT>-STLAN = 1.
<MPES_MAPROJ_BOMNC_RESULT>-STLAL = 1.
<MPES_MAPROJ_BOMNC_RESULT>-STLNR = 1.
ENDLOOP.

LOOP AT IT_MPES_MAPROJ_BOMNC_RESULT INTO WA_MPES_MAPROJ_BOMNC_RESULT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MPES_MAPROJ_BOMNC_RESULT-BOM_VERSN, sy-vline,
WA_MPES_MAPROJ_BOMNC_RESULT-IDNRK, sy-vline,
WA_MPES_MAPROJ_BOMNC_RESULT-MEINS, sy-vline,
WA_MPES_MAPROJ_BOMNC_RESULT-MENGE, sy-vline,
WA_MPES_MAPROJ_BOMNC_RESULT-STVKN, sy-vline,
WA_MPES_MAPROJ_BOMNC_RESULT-STVKN_VERSN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPES_MAPROJ_BOMNC_RESULT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPES_MAPROJ_BOMNC_RESULT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPES_MAPROJ_BOMNC_RESULT INTO WA_MPES_MAPROJ_BOMNC_RESULT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_MAPROJ_BOMNC_RESULT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_MAPROJ_BOMNC_RESULT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_MAPROJ_BOMNC_RESULT-STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_MAPROJ_BOMNC_RESULT-STLAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_MAPROJ_BOMNC_RESULT-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_MAPROJ_BOMNC_RESULT-STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field IDNRK CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_MAPROJ_BOMNC_RESULT-IDNRK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_MAPROJ_BOMNC_RESULT-IDNRK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_MAPROJ_BOMNC_RESULT-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_MAPROJ_BOMNC_RESULT-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field NEW_IDNRK CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_MAPROJ_BOMNC_RESULT-NEW_IDNRK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_MAPROJ_BOMNC_RESULT-NEW_IDNRK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field NEW_MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_MAPROJ_BOMNC_RESULT-NEW_MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_MAPROJ_BOMNC_RESULT-NEW_MEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPES_MAPROJ_BOMNC_RESULT_STR,
MATNR TYPE STRING,
WERKS TYPE STRING,
STLAN TYPE STRING,
STLAL TYPE STRING,
STLNR TYPE STRING,
BOM_VERSN TYPE STRING,
IDNRK TYPE STRING,
MEINS TYPE STRING,
MENGE TYPE STRING,
STVKN TYPE STRING,
STVKN_VERSN TYPE STRING,
UPDATE_TYPE TYPE STRING,
NEW_BOM_VERSN TYPE STRING,
NEW_IDNRK TYPE STRING,
NEW_MEINS TYPE STRING,
NEW_MENGE TYPE STRING,
NEW_STVKN TYPE STRING,
NEW_STVKN_VERSN TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPES_MAPROJ_BOMNC_RESULT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-MATNR sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-WERKS sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-STLAN sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-STLAL sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-STLNR sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-BOM_VERSN sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-IDNRK sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-MEINS sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-MENGE sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-STVKN sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-STVKN_VERSN sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-UPDATE_TYPE sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-NEW_BOM_VERSN sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-NEW_IDNRK sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-NEW_MEINS sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-NEW_MENGE sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-NEW_STVKN sy-vline
WA_MPES_MAPROJ_BOMNC_RESULT_STR-NEW_STVKN_VERSN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.