ABAP Select data from SAP table MPES_PE_BOM_EXPL_RESULT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPES_PE_BOM_EXPL_RESULT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPES_PE_BOM_EXPL_RESULT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the MPES_PE_BOM_EXPL_RESULT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_MPES_PE_BOM_EXPL_RESULT TYPE STANDARD TABLE OF MPES_PE_BOM_EXPL_RESULT, WA_MPES_PE_BOM_EXPL_RESULT TYPE MPES_PE_BOM_EXPL_RESULT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <MPES_PE_BOM_EXPL_RESULT> TYPE MPES_PE_BOM_EXPL_RESULT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_MPES_PE_BOM_EXPL_RESULT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM MPES_PE_BOM_EXPL_RESULT INTO TABLE IT_MPES_PE_BOM_EXPL_RESULT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM MPES_PE_BOM_EXPL_RESULT * INTO TABLE @DATA(IT_MPES_PE_BOM_EXPL_RESULT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_MPES_PE_BOM_EXPL_RESULT INDEX 1 INTO DATA(WA_MPES_PE_BOM_EXPL_RESULT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_MPES_PE_BOM_EXPL_RESULT ASSIGNING <MPES_PE_BOM_EXPL_RESULT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPES_PE_BOM_EXPL_RESULT>-NODE = 1.
<MPES_PE_BOM_EXPL_RESULT>-HEADER_NODE = 1.
<MPES_PE_BOM_EXPL_RESULT>-MATNR = 1.
<MPES_PE_BOM_EXPL_RESULT>-WERKS = 1.
<MPES_PE_BOM_EXPL_RESULT>-STLAN = 1.
ENDLOOP. LOOP AT IT_MPES_PE_BOM_EXPL_RESULT INTO WA_MPES_PE_BOM_EXPL_RESULT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_MPES_PE_BOM_EXPL_RESULT-STLNR, sy-vline,
WA_MPES_PE_BOM_EXPL_RESULT-STLAL, sy-vline,
WA_MPES_PE_BOM_EXPL_RESULT-BOM_VERSN, sy-vline,
WA_MPES_PE_BOM_EXPL_RESULT-TECHS, sy-vline,
WA_MPES_PE_BOM_EXPL_RESULT-STLKN, sy-vline,
WA_MPES_PE_BOM_EXPL_RESULT-STPOZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPES_PE_BOM_EXPL_RESULT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPES_PE_BOM_EXPL_RESULT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPES_PE_BOM_EXPL_RESULT INTO WA_MPES_PE_BOM_EXPL_RESULT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_PE_BOM_EXPL_RESULT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PE_BOM_EXPL_RESULT-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_PE_BOM_EXPL_RESULT-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PE_BOM_EXPL_RESULT-STLNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_PE_BOM_EXPL_RESULT-STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PE_BOM_EXPL_RESULT-STLAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_PE_BOM_EXPL_RESULT-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PE_BOM_EXPL_RESULT-AENNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field IDNRK CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_PE_BOM_EXPL_RESULT-IDNRK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PE_BOM_EXPL_RESULT-IDNRK.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field POSNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_PE_BOM_EXPL_RESULT-POSNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PE_BOM_EXPL_RESULT-POSNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_PE_BOM_EXPL_RESULT-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PE_BOM_EXPL_RESULT-MEINS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field PARENT_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_PE_BOM_EXPL_RESULT-PARENT_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PE_BOM_EXPL_RESULT-PARENT_MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PARENT_STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_PE_BOM_EXPL_RESULT-PARENT_STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PE_BOM_EXPL_RESULT-PARENT_STLAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field PARENT_STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_PE_BOM_EXPL_RESULT-PARENT_STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PE_BOM_EXPL_RESULT-PARENT_STLNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field COMP_STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_PE_BOM_EXPL_RESULT-COMP_STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PE_BOM_EXPL_RESULT-COMP_STLAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field COMP_STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_PE_BOM_EXPL_RESULT-COMP_STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PE_BOM_EXPL_RESULT-COMP_STLNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPES_PE_BOM_EXPL_RESULT_STR,
NODE TYPE STRING,
HEADER_NODE TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
STLAN TYPE STRING,
STLNR TYPE STRING,
STLAL TYPE STRING,
BOM_VERSN TYPE STRING,
TECHS TYPE STRING,
STLKN TYPE STRING,
STPOZ TYPE STRING,
STVKN TYPE STRING,
STVKN_VERSN TYPE STRING,
AENNR TYPE STRING,
IDNRK TYPE STRING,
POSTP TYPE STRING,
POSNR TYPE STRING,
MEINS TYPE STRING,
MENGE TYPE STRING,
RFPNT TYPE STRING,
CATYP TYPE STRING,
EFFTYP TYPE STRING,
SEL TYPE STRING,
PARENT_MATNR TYPE STRING,
PARENT_WERKS TYPE STRING,
PARENT_STLAN TYPE STRING,
PARENT_STLAL TYPE STRING,
PARENT_STLNR TYPE STRING,
PARENT_BOM_VERSN TYPE STRING,
PARENT_STLKN TYPE STRING,
PARENT_STVKN TYPE STRING,
COMP_WERKS TYPE STRING,
COMP_STLAN TYPE STRING,
COMP_STLAL TYPE STRING,
COMP_STLNR TYPE STRING,
COMP_BOM_VERSN TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPES_PE_BOM_EXPL_RESULT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-NODE sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-HEADER_NODE sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-MATNR sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-WERKS sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-STLAN sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-STLNR sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-STLAL sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-BOM_VERSN sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-TECHS sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-STLKN sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-STPOZ sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-STVKN sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-STVKN_VERSN sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-AENNR sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-IDNRK sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-POSTP sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-POSNR sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-MEINS sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-MENGE sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-RFPNT sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-CATYP sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-EFFTYP sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-SEL sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-PARENT_MATNR sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-PARENT_WERKS sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-PARENT_STLAN sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-PARENT_STLAL sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-PARENT_STLNR sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-PARENT_BOM_VERSN sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-PARENT_STLKN sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-PARENT_STVKN sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-COMP_WERKS sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-COMP_STLAN sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-COMP_STLAL sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-COMP_STLNR sy-vline
WA_MPES_PE_BOM_EXPL_RESULT_STR-COMP_BOM_VERSN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.