ABAP Select data from SAP table MPES_PLAN_MBOM_MFG_SUB into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPES_PLAN_MBOM_MFG_SUB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPES_PLAN_MBOM_MFG_SUB. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the MPES_PLAN_MBOM_MFG_SUB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_MPES_PLAN_MBOM_MFG_SUB TYPE STANDARD TABLE OF MPES_PLAN_MBOM_MFG_SUB, WA_MPES_PLAN_MBOM_MFG_SUB TYPE MPES_PLAN_MBOM_MFG_SUB, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <MPES_PLAN_MBOM_MFG_SUB> TYPE MPES_PLAN_MBOM_MFG_SUB. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_MPES_PLAN_MBOM_MFG_SUB. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM MPES_PLAN_MBOM_MFG_SUB INTO TABLE IT_MPES_PLAN_MBOM_MFG_SUB. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM MPES_PLAN_MBOM_MFG_SUB * INTO TABLE @DATA(IT_MPES_PLAN_MBOM_MFG_SUB2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_MPES_PLAN_MBOM_MFG_SUB INDEX 1 INTO DATA(WA_MPES_PLAN_MBOM_MFG_SUB2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_MPES_PLAN_MBOM_MFG_SUB ASSIGNING <MPES_PLAN_MBOM_MFG_SUB>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPES_PLAN_MBOM_MFG_SUB>-SRCE_STLTY = 1.
<MPES_PLAN_MBOM_MFG_SUB>-SRCE_STLAN = 1.
<MPES_PLAN_MBOM_MFG_SUB>-SRCE_STLNR = 1.
<MPES_PLAN_MBOM_MFG_SUB>-SRCE_STLAL = 1.
<MPES_PLAN_MBOM_MFG_SUB>-SRCE_STVKN = 1.
ENDLOOP. LOOP AT IT_MPES_PLAN_MBOM_MFG_SUB INTO WA_MPES_PLAN_MBOM_MFG_SUB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_MPES_PLAN_MBOM_MFG_SUB-SRCE_STVKN_VERSN, sy-vline,
WA_MPES_PLAN_MBOM_MFG_SUB-SRCE_BOM_VERSN, sy-vline,
WA_MPES_PLAN_MBOM_MFG_SUB-SRCE_BOM_CHANGE_NUMBER, sy-vline,
WA_MPES_PLAN_MBOM_MFG_SUB-SRCE_MATERIAL, sy-vline,
WA_MPES_PLAN_MBOM_MFG_SUB-TGT_STLTY, sy-vline,
WA_MPES_PLAN_MBOM_MFG_SUB-TGT_STLAN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPES_PLAN_MBOM_MFG_SUB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPES_PLAN_MBOM_MFG_SUB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPES_PLAN_MBOM_MFG_SUB INTO WA_MPES_PLAN_MBOM_MFG_SUB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit NUMCV, internal->external for field SRCE_STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_PLAN_MBOM_MFG_SUB-SRCE_STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PLAN_MBOM_MFG_SUB-SRCE_STLNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SRCE_STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_PLAN_MBOM_MFG_SUB-SRCE_STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PLAN_MBOM_MFG_SUB-SRCE_STLAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SRCE_BOM_CHANGE_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_PLAN_MBOM_MFG_SUB-SRCE_BOM_CHANGE_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PLAN_MBOM_MFG_SUB-SRCE_BOM_CHANGE_NUMBER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field SRCE_MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_PLAN_MBOM_MFG_SUB-SRCE_MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PLAN_MBOM_MFG_SUB-SRCE_MATERIAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field TGT_STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_MPES_PLAN_MBOM_MFG_SUB-TGT_STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PLAN_MBOM_MFG_SUB-TGT_STLNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field TGT_STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_PLAN_MBOM_MFG_SUB-TGT_STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PLAN_MBOM_MFG_SUB-TGT_STLAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field TGT_BOM_CHANGE_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_MPES_PLAN_MBOM_MFG_SUB-TGT_BOM_CHANGE_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PLAN_MBOM_MFG_SUB-TGT_BOM_CHANGE_NUMBER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field TGT_ORIGINAL_MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_PLAN_MBOM_MFG_SUB-TGT_ORIGINAL_MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PLAN_MBOM_MFG_SUB-TGT_ORIGINAL_MATERIAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field TGT_SUBSTITUTE_MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPES_PLAN_MBOM_MFG_SUB-TGT_SUBSTITUTE_MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PLAN_MBOM_MFG_SUB-TGT_SUBSTITUTE_MATERIAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field TGT_ORIGINAL_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_PLAN_MBOM_MFG_SUB-TGT_ORIGINAL_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PLAN_MBOM_MFG_SUB-TGT_ORIGINAL_UOM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field TGT_SUBSTITUTE_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPES_PLAN_MBOM_MFG_SUB-TGT_SUBSTITUTE_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPES_PLAN_MBOM_MFG_SUB-TGT_SUBSTITUTE_UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPES_PLAN_MBOM_MFG_SUB_STR,
SRCE_STLTY TYPE STRING,
SRCE_STLAN TYPE STRING,
SRCE_STLNR TYPE STRING,
SRCE_STLAL TYPE STRING,
SRCE_STVKN TYPE STRING,
SRCE_STVKN_VERSN TYPE STRING,
SRCE_BOM_VERSN TYPE STRING,
SRCE_BOM_CHANGE_NUMBER TYPE STRING,
SRCE_MATERIAL TYPE STRING,
TGT_STLTY TYPE STRING,
TGT_STLAN TYPE STRING,
TGT_STLNR TYPE STRING,
TGT_STLAL TYPE STRING,
TGT_STVKN TYPE STRING,
TGT_STVKN_VERSN TYPE STRING,
TGT_BOM_VERSN TYPE STRING,
TGT_BOM_CHANGE_NUMBER TYPE STRING,
TGT_ORIGINAL_MATERIAL TYPE STRING,
TGT_SUBSTITUTE_MATERIAL TYPE STRING,
TGT_ORIGINAL_QTY TYPE STRING,
TGT_SUBSTITUTE_QTY TYPE STRING,
TGT_ORIGINAL_UOM TYPE STRING,
TGT_SUBSTITUTE_UOM TYPE STRING,
TGT_SUB_ASGNMNT_VERSN TYPE STRING,
CREATED_DATE TYPE STRING,
CREATED_USER TYPE STRING,
CHANGED_DATE TYPE STRING,
CHANGED_USER TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPES_PLAN_MBOM_MFG_SUB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-SRCE_STLTY sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-SRCE_STLAN sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-SRCE_STLNR sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-SRCE_STLAL sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-SRCE_STVKN sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-SRCE_STVKN_VERSN sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-SRCE_BOM_VERSN sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-SRCE_BOM_CHANGE_NUMBER sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-SRCE_MATERIAL sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-TGT_STLTY sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-TGT_STLAN sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-TGT_STLNR sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-TGT_STLAL sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-TGT_STVKN sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-TGT_STVKN_VERSN sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-TGT_BOM_VERSN sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-TGT_BOM_CHANGE_NUMBER sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-TGT_ORIGINAL_MATERIAL sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-TGT_SUBSTITUTE_MATERIAL sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-TGT_ORIGINAL_QTY sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-TGT_SUBSTITUTE_QTY sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-TGT_ORIGINAL_UOM sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-TGT_SUBSTITUTE_UOM sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-TGT_SUB_ASGNMNT_VERSN sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-CREATED_DATE sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-CREATED_USER sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-CHANGED_DATE sy-vline
WA_MPES_PLAN_MBOM_MFG_SUB_STR-CHANGED_USER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.