ABAP Select data from SAP table MPN_WA_EXCH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP MPN_WA_EXCH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to MPN_WA_EXCH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the MPN_WA_EXCH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_MPN_WA_EXCH TYPE STANDARD TABLE OF MPN_WA_EXCH,
      WA_MPN_WA_EXCH TYPE MPN_WA_EXCH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <MPN_WA_EXCH> TYPE MPN_WA_EXCH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_MPN_WA_EXCH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM MPN_WA_EXCH
  INTO TABLE IT_MPN_WA_EXCH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM MPN_WA_EXCH
*  INTO TABLE @DATA(IT_MPN_WA_EXCH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_MPN_WA_EXCH INDEX 1 INTO DATA(WA_MPN_WA_EXCH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_MPN_WA_EXCH ASSIGNING <MPN_WA_EXCH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<MPN_WA_EXCH>-MARK = 1.
<MPN_WA_EXCH>-MATNR = 1.
<MPN_WA_EXCH>-WERKS = 1.
<MPN_WA_EXCH>-BERID = 1.
<MPN_WA_EXCH>-LGORT = 1.
ENDLOOP.

LOOP AT IT_MPN_WA_EXCH INTO WA_MPN_WA_EXCH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_MPN_WA_EXCH-MENGE, sy-vline,
WA_MPN_WA_EXCH-MEINS, sy-vline,
WA_MPN_WA_EXCH-BESTD, sy-vline,
WA_MPN_WA_EXCH-UNIT, sy-vline,
WA_MPN_WA_EXCH-LIGHT, sy-vline,
WA_MPN_WA_EXCH-MRPGR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_MPN_WA_EXCH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_MPN_WA_EXCH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_MPN_WA_EXCH INTO WA_MPN_WA_EXCH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_MPN_WA_EXCH-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPN_WA_EXCH-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPN_WA_EXCH-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPN_WA_EXCH-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_MPN_WA_EXCH-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_MPN_WA_EXCH-UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_MPN_WA_EXCH_STR,
MARK TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
BERID TYPE STRING,
LGORT TYPE STRING,
MENGE TYPE STRING,
MEINS TYPE STRING,
BESTD TYPE STRING,
UNIT TYPE STRING,
LIGHT TYPE STRING,
MRPGR TYPE STRING,
LEADP TYPE STRING,END OF T_EKKO_STR. DATA: WA_MPN_WA_EXCH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_MPN_WA_EXCH_STR-MARK sy-vline
WA_MPN_WA_EXCH_STR-MATNR sy-vline
WA_MPN_WA_EXCH_STR-WERKS sy-vline
WA_MPN_WA_EXCH_STR-BERID sy-vline
WA_MPN_WA_EXCH_STR-LGORT sy-vline
WA_MPN_WA_EXCH_STR-MENGE sy-vline
WA_MPN_WA_EXCH_STR-MEINS sy-vline
WA_MPN_WA_EXCH_STR-BESTD sy-vline
WA_MPN_WA_EXCH_STR-UNIT sy-vline
WA_MPN_WA_EXCH_STR-LIGHT sy-vline
WA_MPN_WA_EXCH_STR-MRPGR sy-vline
WA_MPN_WA_EXCH_STR-LEADP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.