ABAP Select data from SAP table OBOM_WB_S_PRM2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP OBOM_WB_S_PRM2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to OBOM_WB_S_PRM2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the OBOM_WB_S_PRM2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_OBOM_WB_S_PRM2 TYPE STANDARD TABLE OF OBOM_WB_S_PRM2,
      WA_OBOM_WB_S_PRM2 TYPE OBOM_WB_S_PRM2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <OBOM_WB_S_PRM2> TYPE OBOM_WB_S_PRM2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_OBOM_WB_S_PRM2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM OBOM_WB_S_PRM2
  INTO TABLE IT_OBOM_WB_S_PRM2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM OBOM_WB_S_PRM2
*  INTO TABLE @DATA(IT_OBOM_WB_S_PRM22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_OBOM_WB_S_PRM2 INDEX 1 INTO DATA(WA_OBOM_WB_S_PRM22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_OBOM_WB_S_PRM2 ASSIGNING <OBOM_WB_S_PRM2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<OBOM_WB_S_PRM2>-VBELN = 1.
<OBOM_WB_S_PRM2>-POSNR = 1.
<OBOM_WB_S_PRM2>-WERKS = 1.
<OBOM_WB_S_PRM2>-DATUV = 1.
<OBOM_WB_S_PRM2>-MATNR_TOP = 1.
ENDLOOP.

LOOP AT IT_OBOM_WB_S_PRM2 INTO WA_OBOM_WB_S_PRM2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_OBOM_WB_S_PRM2-NO_CHECK_ORDER_BOM, sy-vline,
WA_OBOM_WB_S_PRM2-NO_CHECK_MATERIAL_STATUS, sy-vline,
WA_OBOM_WB_S_PRM2-CALL_CAVC_EXEC, sy-vline,
WA_OBOM_WB_S_PRM2-KDST_INST_TAB, sy-vline,
WA_OBOM_WB_S_PRM2-NOT_ALLOWED, sy-vline,
WA_OBOM_WB_S_PRM2-MSG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_OBOM_WB_S_PRM2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_OBOM_WB_S_PRM2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_OBOM_WB_S_PRM2 INTO WA_OBOM_WB_S_PRM2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OBOM_WB_S_PRM2-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBOM_WB_S_PRM2-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR_TOP CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_OBOM_WB_S_PRM2-MATNR_TOP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBOM_WB_S_PRM2-MATNR_TOP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_OBOM_WB_S_PRM2-SYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_OBOM_WB_S_PRM2-SYSTEM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_OBOM_WB_S_PRM2_STR,
VBELN TYPE STRING,
POSNR TYPE STRING,
WERKS TYPE STRING,
DATUV TYPE STRING,
MATNR_TOP TYPE STRING,
NO_CHECK_ORDER_BOM TYPE STRING,
NO_CHECK_MATERIAL_STATUS TYPE STRING,
CALL_CAVC_EXEC TYPE STRING,
KDST_INST_TAB TYPE STRING,
NOT_ALLOWED TYPE STRING,
MSG TYPE STRING,
TYPE TYPE STRING,
ID TYPE STRING,
NUMBER TYPE STRING,
MESSAGE TYPE STRING,
LOG_NO TYPE STRING,
LOG_MSG_NO TYPE STRING,
MESSAGE_V1 TYPE STRING,
MESSAGE_V2 TYPE STRING,
MESSAGE_V3 TYPE STRING,
MESSAGE_V4 TYPE STRING,
PARAMETER TYPE STRING,
ROW TYPE STRING,
FIELD TYPE STRING,
SYSTEM TYPE STRING,
NO_CONVERSION_MATNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_OBOM_WB_S_PRM2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_OBOM_WB_S_PRM2_STR-VBELN sy-vline
WA_OBOM_WB_S_PRM2_STR-POSNR sy-vline
WA_OBOM_WB_S_PRM2_STR-WERKS sy-vline
WA_OBOM_WB_S_PRM2_STR-DATUV sy-vline
WA_OBOM_WB_S_PRM2_STR-MATNR_TOP sy-vline
WA_OBOM_WB_S_PRM2_STR-NO_CHECK_ORDER_BOM sy-vline
WA_OBOM_WB_S_PRM2_STR-NO_CHECK_MATERIAL_STATUS sy-vline
WA_OBOM_WB_S_PRM2_STR-CALL_CAVC_EXEC sy-vline
WA_OBOM_WB_S_PRM2_STR-KDST_INST_TAB sy-vline
WA_OBOM_WB_S_PRM2_STR-NOT_ALLOWED sy-vline
WA_OBOM_WB_S_PRM2_STR-MSG sy-vline
WA_OBOM_WB_S_PRM2_STR-TYPE sy-vline
WA_OBOM_WB_S_PRM2_STR-ID sy-vline
WA_OBOM_WB_S_PRM2_STR-NUMBER sy-vline
WA_OBOM_WB_S_PRM2_STR-MESSAGE sy-vline
WA_OBOM_WB_S_PRM2_STR-LOG_NO sy-vline
WA_OBOM_WB_S_PRM2_STR-LOG_MSG_NO sy-vline
WA_OBOM_WB_S_PRM2_STR-MESSAGE_V1 sy-vline
WA_OBOM_WB_S_PRM2_STR-MESSAGE_V2 sy-vline
WA_OBOM_WB_S_PRM2_STR-MESSAGE_V3 sy-vline
WA_OBOM_WB_S_PRM2_STR-MESSAGE_V4 sy-vline
WA_OBOM_WB_S_PRM2_STR-PARAMETER sy-vline
WA_OBOM_WB_S_PRM2_STR-ROW sy-vline
WA_OBOM_WB_S_PRM2_STR-FIELD sy-vline
WA_OBOM_WB_S_PRM2_STR-SYSTEM sy-vline
WA_OBOM_WB_S_PRM2_STR-NO_CONVERSION_MATNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.